Caracterización de la diferencia entre retroproyección filtrada y Ordered Subsets Expectation Maximization, en imágenes SPECT, utilizando la transformada Wavelet
Characterization of the difference between filtered back projection and ordered subsets expectation maximization in spect images using Wavelet transform
Visitas
3781
A. Péreza, R. Piotrkowskia, R. Gallib, G. La Muraa, FJ. Peñab
a Escuela de Ciencia y Tecnología de la Universidad Nacional de General San Martín. Alem 3901. Villa Ballester. 
b Diagnóstico Médico SRL. Buenos Aires. Argentina.
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Tablas (8)
Fig. 1. --Matrices de los cortes transversales homólogos obtenidos por RPF (primera fila) y OSEM (segunda fila). Las columnas muestran los sucesivos niveles según la TW.
Fig. 2. --Perfiles centrales de las matrices. A) Cortes Transversales; B) nivel N1; C) nivel N2; D) nivel N3. Eje x: píxels. Eje y: número de cuentas.
Tabla 1. VALORES DEL CV Y DR PARA LAS MATRICES ORIGINALES Y SUS RESPECTIVOS NIVELES
Mostrar másMostrar menos
Resumen.--La eficacia de los algoritmos de reconstrucción es un factor importante a fin de garantizar la calidad de imágenes tomográficas de Medicina Nuclear. Existen dos grupos de algoritmos, los analíticos y los de carácter estadístico. El algoritmo de Retroproyección Filtrada (RPF) pertenece al primer grupo mientras que Ordered Subsets Expectation Maximization (OSEM) es uno de los algoritmos del segundo grupo. El objetivo del presente trabajo fue comparar ambos algoritmos utilizando la Transformada Wavelet (TW). Se eligió este instrumento dada su capacidad de separar la imagen en distintos niveles de frecuencia sin perder información posicional de los mismos. La misma se aplicó con base Haar y sin decimación por niveles, a fin de poder comparar matrices de igual tamaño. Se prestó atención a la presencia relativa de tres perturbaciones típicas: el ruido de Poisson, los artificios anulares que expresan una deficiente corrección de la uniformidad planar y el fenómeno de la atenuación. Con este propósito se estudiaron cortes transversales homólogos de distribuciones homogéneas de actividad. Se comprobó, que el algoritmo OSEM no solamente introduce importantes mejoras, en cuanto a filtrar el ruido de Poisson, sino que también disminuye los artificios anulares, en particular en la zona de la imagen coincidente con el centro de rotación. El fenómeno de la atenuación, para el caso de estas imágenes, mostró igual intensidad con ambos algoritmos a excepción de la zona periférica donde OSEM produjo un aumento aparente de la concentración de actividad ligeramente más importante que RPF. Estas observaciones alientan el interés de continuar en la idea de utilizar la TW no sólo para identificar, sino también para tratar de disminuir la presencia de artificios característicos de éstas imágenes.
Palabras clave:
Retroproyección filtrada
OSEM
Transformada Wavelet
Summary.--Efficiency of reconstruction algorithms is important to guarantee quality of Nuclear Medicine tomographic images. The algorithms belong to one of two types: analytical or statistical. The Filtered Back Projection (BP) algorithm belongs to the first group and the Ordered Subsets Expectation Maximization (OSEM) algorithm belongs to the second group. The aim of the present paper was to compare both algorithms by means of the Wavelet Transform (WT). This tool was selected because of its capability to divide the image into different frequency levels without losing information about their spatial position. The WT was applied on the Haar basis without decimation in order to compare matrixes of the same size. Attention was drawn to the relative presence of three typical perturbations: Poisson noise, annular artifacts that express a deficient correction to the planar uniformity and attenuation phenomenon. With these purposes, we studied homologue transversal slices of images of homogeneous distribution of activity. The OSEM algorithm not only greatly improves the filtering of the Poisson noise, but also diminishes the annular artifacts, mainly at the image zone that coincides with the rotation center. The intensity of the attenuation phenomenon was the same with both algorithms, except in the peripheral zone where OSEM showed a slightly higher activity than BP. These observations encourage our interest to continue applying the WT not only to identify the artifacts, but also to try to decrease their deleterious influence on Nuclear Medicine images.
Keywords:
Filtered back projection
OSEM
Wavelet transform

Artículo

Opciones para acceder a los textos completos de la publicación Revista Española de Medicina Nuclear e Imagen Molecular
Socio
Si es usted socio de la Sociedad Española de Medicina Nuclear e Imagen Molecular (SEMNIM) puede acceder al texto completo de los contenidos de la Revista Española de Medicina Nuclear e Imagen Molecular desde los enlaces a la revista publicados en la web de la SEMNIN (enlace a https://semnim.es/iniciar-sesion/), previo inicio de sesión como socio. Si tiene problemas de acceso puede contactar con la Secretaría Técnica de la SEMNIM en el correo electrónico secretaria.tecnica@semnim.es o en el teléfono: + 34 619 594 780
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Revista Española de Medicina Nuclear e Imagen Molecular

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos