metricas
covid
Buscar en
Revista Española de Medicina Nuclear e Imagen Molecular
Toda la web
Inicio Revista Española de Medicina Nuclear e Imagen Molecular Gammagrafía con 75Se-ácido tauroselcólico (75SeHCAT®), ¿prueba de referenci...
Información de la revista
Vol. 38. Núm. 5.
Páginas 305-311 (septiembre - octubre 2019)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Visitas
1082
Vol. 38. Núm. 5.
Páginas 305-311 (septiembre - octubre 2019)
Colaboración especial
Gammagrafía con 75Se-ácido tauroselcólico (75SeHCAT®), ¿prueba de referencia en la malabsorción de ácidos biliares?
75Se-Homocholic acid taurine scintigraphy (75SeHCAT®), a standard benchmark test in bile acid malabsorption?
Visitas
1082
A. Baena García
Autor para correspondencia
alvaronuclear16@gmail.com

Autor para correspondencia.
, F. Partida Palma, S. García Martínez, M. de Bonilla Candau, M. Pajares Vinardell
Servicio de Medicina Nuclear, Hospital Universitario Puerta del Mar, Cádiz, España
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (6)
Mostrar másMostrar menos
Resumen

La diarrea crónica por malabsorción de ácidos biliares (MAB) es una patología infradiagnosticada. Se dispone de diferentes herramientas diagnósticas, aunque en la actualidad no existe consenso sobre cuál de estas sería la prueba de referencia o gold standard. En esta revisión se valora la posibilidad de utilizar la gammagrafía con 75Se-ácido tauroselcólico (75SeHCAT®) como prueba diagnóstica de referencia y su perspectiva de futuro. Se realizó una búsqueda bibliográfica en Pubmed y OVID, obteniéndose un total de 57 trabajos y usándose finalmente 26 de ellos tras ser seleccionados bajo los conceptos de gold standard, exactitud diagnóstica y otros biomarcadores. Valoramos las ventajas e inconvenientes de las diferentes herramientas diagnósticas: 14C-glicocolato, medición de ácidos biliares en heces, C4 en suero, FGF19 en suero, colestiramina y gammagrafía con ácido tauroselcólico. Consideramos que la gammagrafía con 75SeHCAT® es la prueba diagnóstica más recomendada en Europa para el diagnóstico de MAB al presentar los índices más elevados de sensibilidad y especificidad. Presenta una gran relación coste-beneficio, por lo que es la prueba con mayor grado de recomendación. Sin embargo, aún no es posible su uso de forma reconocida como gold standard debido a la falta de estudios que proporcionen datos concluyentes que permitan su consenso. Mientras tanto, se podría aconsejar el uso combinado de la prueba con colestiramina en todos los pacientes que queramos evaluar, independientemente del resultado gammagráfico, como uso de patrón de referencia.

Palabras clave:
75SeHCAT®
Malabsorción de ácidos biliares
Diarrea crónica
Colestiramina
C4
Abstract

Chronic diarrhoea due to bile acid malabsorption (BAM) is an underdiagnosed pathology. Different diagnostic tools are available. However, there is currently no consensus on which of these would be the benchmark test or gold standard. This review evaluates the possibility of using 75Se-taurocholic acid (75SeHCAT®) scintigraphy as a benchmark diagnostic test and its perspective for the future. A literature review was conducted in Pubmed and OVID obtaining a total of 57 papers, 26 of which were finally used after being selected under the concepts of gold standard, diagnostic accuracy and other biomarkers. We evaluated the advantages and disadvantages of the different diagnostic tools: 14C-glycocholate, measurement of bile acids in faeces, C4 in serum, FGF19 in serum, cholestyramine, and 75Se-tauroselcolic acid scintigraphy. We consider that the 75SeHCAT® scan is the most recommended diagnostic test in Europe for diagnosing BAM as it presents the highest values of sensitivity and specificity. It has a significant cost-benefit ratio, making it the test with the highest degree of recommendation. However, it is still not possible to use it in a recognised way as a gold standard due to the lack of studies that provide conclusive data that allow consensus. In the meantime, the combined use of cholestyramine testing in all patients we want to evaluate, regardless of the scintigraphy result, could be encouraged as a benchmark standard.

Keywords:
75SeHCAT®
Bile acid malabsorption
Chronic diarrhoea
Cholestyramine
C4

Artículo

Opciones para acceder a los textos completos de la publicación Revista Española de Medicina Nuclear e Imagen Molecular
Socio
Si es usted socio de la Sociedad Española de Medicina Nuclear e Imagen Molecular (SEMNIM) puede acceder al texto completo de los contenidos de la Revista Española de Medicina Nuclear e Imagen Molecular desde los enlaces a la revista publicados en la web de la SEMNIN (enlace a https://semnim.es/iniciar-sesion/), previo inicio de sesión como socio. Si tiene problemas de acceso puede contactar con la Secretaría Técnica de la SEMNIM en el correo electrónico secretaria.tecnica@semnim.es o en el teléfono: + 34 619 594 780
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Revista Española de Medicina Nuclear e Imagen Molecular

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos