metricas
covid
Buscar en
Revista Española de Medicina Nuclear e Imagen Molecular
Toda la web
Inicio Revista Española de Medicina Nuclear e Imagen Molecular Gammagrafía con 99mTc-MIBI en el diagnóstico de la invasión ganglionar axilar...
Información de la revista
Vol. 19. Núm. 6.
Páginas 416-422 (octubre 2000)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Vol. 19. Núm. 6.
Páginas 416-422 (octubre 2000)
Gammagrafía con 99mTc-MIBI en el diagnóstico de la invasión ganglionar axilar del cáncer de mama
Scintigraphy with 99m Tc-MIBI of the axillary lymph node invasion of the breast cancer
Visitas
2145
F. Muleroa, F. Nicolása, M I. Castellóna, M A. Clavera, L. Abada, J A. Nuño de la Rosaa
a Servicios de Medicina Nuclear y Ginecología y Obstetricia del Hospital Universitario Virgen de la Arrixaca. El Palmar. Murcia.
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (2)
La presencia de ganglios locorregionales afectados debe considerarse como uno de los factores pronósticos más importantes en el cáncer de mama. En la actualidad el clínico está condicionado por la absoluta falta de una metodología capaz de proporcionar un juicio pre-operatorio atendible sobre los ganglios axilares que, en caso de negatividad, permita evitar su extirpación quirúrgica. En nuestro estudio pretendemos evaluar la utilidad de la gammagrafía mamaria con 99mTc-MIBI en el diagnóstico preoperatorio de la invasión ganglionar axilar y analizar la relación entre la captación del radiofármaco y la presencia de mayor número de ganglios afectados. Material y método: Estudiamos 84 pacientes con cáncer de mama. A todas ellas se les realizó gammagrafía mamaria con 99mTc-MIBI calculándose mediante un análisis semicuantitativo la ratio tumor/fondo en cada proyección. Tras la cirugía se determinó la invasión ganglionar axila. Los resultados de la gammagrafía mamaria con 99mTc-MIBI en la detección de invasión ganglionar axilar fueron sensibilidad 36%, especificidad 100%, valor predictivo positivo 100% y valor predictivo negativo 48%. En nuestro estudio no encontramos correlación entre la captación de 99mTc-MIBI en la lesión primaria y el número de ganglios axilares invadidos. Conclusión: La gammagrafía mamaria con 99mTc-MIBI puede aportar datos complementarios al diagnóstico pre-operatorio de la invasión ganglionar axilar, basándonos en la elevada especificidad y valor predictivo positivo de la técnica.
Palabras clave:
Cáncer de mama
Ganglios axilares
Gammagrafía mamaria
The presence of affected locoregional lymph nodes should be considered as one of the most important prognostic factors of breast cancer. At present, the clinician is conditioned by an absolute lack of an efficient methodology to evaluate the possible invasion of the axillary lymph nodes, which if negative, would make it possible to avoid surgical excision. In this study, we will evaluate the use of the 99mTc-MIBI scintigraphy in the pre-surgical diagnosis of axillary lymph node invasion and will analyze the relationship between the 99mTc-MIBI uptake and the number of lymph nodes affected. Material and methods: 84 patients diagnosed of breast cancer were analyzed in this study. All of them underwent a 99mTc-MIBI scintigraphy, and the tumor/background ratio was determined semiquantitively for each image. The axillary lymph node invasion was determined following surgery. Results: The sensitivity of the breast scintigraphy with 99mTc-MIBI for detection of lymph node invasion is 36% and the specificity is 100%. The positive predictive value is 100% and the negative one 48%. In the current study, we failed to detect correlation between the intensity of 99mTc-MIBI uptake in the primary tumor and the number of affected axillary lymph nodes. Conclusion: 99mTc-MIBI breast scintigraphy can provide complementary information for the presurgical diagnosis of breast cancer axillary lymph node invasion. 99mTc-MIBI breast scintigraphy shows high specificity and a high predictive value.
Keywords:
Breast cancer
Axillary lymph nodes
Breast scintigraphy

Artículo

Opciones para acceder a los textos completos de la publicación Revista Española de Medicina Nuclear e Imagen Molecular
Socio
Si es usted socio de la Sociedad Española de Medicina Nuclear e Imagen Molecular (SEMNIM) puede acceder al texto completo de los contenidos de la Revista Española de Medicina Nuclear e Imagen Molecular desde los enlaces a la revista publicados en la web de la SEMNIN (enlace a https://semnim.es/iniciar-sesion/), previo inicio de sesión como socio. Si tiene problemas de acceso puede contactar con la Secretaría Técnica de la SEMNIM en el correo electrónico secretaria.tecnica@semnim.es o en el teléfono: + 34 619 594 780
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Revista Española de Medicina Nuclear e Imagen Molecular

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos