metricas
covid
Buscar en
Revista Española de Medicina Nuclear e Imagen Molecular
Toda la web
Inicio Revista Española de Medicina Nuclear e Imagen Molecular Localización simultánea de neoplasias de mama no palpables y estudio del gangl...
Información de la revista
Vol. 24. Núm. 2.
Páginas 101-106 (marzo 2005)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Vol. 24. Núm. 2.
Páginas 101-106 (marzo 2005)
Localización simultánea de neoplasias de mama no palpables y estudio del ganglio centinela (GC) mediante técnicas radioisotópicas
Simultaneous location of non-palpable breast neoplasms and sentinel node (SN) study by radioisotopic techniques
Visitas
2354
M. Cortésa, MT. Bajéna, M. Gila, E. Benitob, A. Morenob, A. Gumàb, Y. Ricarta, J. Martin-Comína
a Servicio de Medicina Nuclear. Hospital de Bellvitge. L'Hospitalet de Llobregat.
b Unitat Funcional de Mama. Hospital de Bellvitge. L'Hospitalet de Llobregat.
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (2)
Objetivo: Obtener una correcta localización de lesiones no palpables de mama, con alta sospecha de malignidad y la detección del GC mediante técnicas radiosotópicas. Material y método: Se han estudiado 31 pacientes de edad comprendida entre 35 y 79 años, con lesiones no palpables de mama detectadas mediante mamografía y/o ecografía. Todas las pacientes fueron diagnosticadas de cáncer de mama y tratadas con quimioterapia primaria. A todas las pacientes se les practicó disección axilar total. 24 h antes de la intervención a todas ellas se les administró una dosis de 37 MBq (1 mCi) de macroagregados de albúmina (MAA) marcados con 99mTc, en el centro de la lesión, mediante guía ecográfica. Se practicaron imágenes gammagráficas en proyecciones anterior y lateral (en decúbito prono con mama colgante) para comprobar la correcta localización del radiofármaco. Seguidamente se les realizó estudio del GC mediante la administración subdérmica de una dosis de 18 MBq (0,5 mCi) de nanocoloide marcado con 99mTc. La localización del GC fue marcada en la piel con tinta indeleble. La localización intraquirúrgica de la lesión de la mama y del GC se realizó con ayuda de una sonda gammadetectora. La correcta colocación del radiofármaco intralesional, la existencia de bordes libres de enfermedad y el estudio histológico del GC fueron realizadas por el anatomopatólogo en el acto operatorio. El estudio histopatológico diferido se llevó a cabo con técnicas con hematoxilina-eosina e inmunohistoquimia. Resultados: En 29 de las 31 localizaciones de la lesión, había una buena colocación del radiotrazador (93,5 %), hubo 1 caso de contaminación del trayecto de la aguja y otro que no coincidía con la lesión, por mala colocación. La localización del GC fue del 96 % en axila y del 4 % en axila y mamaria interna. El GC se localizó en quirófano en 28/31 pacientes (90 %). Conclusión: La localización simultánea radioguiada de las lesiones ocultas de la mama y del ganglio centinela es un método sencillo, bien tolerado por las pacientes y que permite realizarse en un solo acto operatorio.
Palabras clave:
Quimioterapia primaria
Cáncer de mama
Ganglio centinela
Objective: To obtain correct location of non-palpable breast lesions, with high suspicion of malignancy and detection of SN by radiosotopic techniques. Material and methods: Thirty-one patients whose ages ranged from 35 to 79 years, with non-palpable breast lesions detected by mammography and/or ultrasonography were studied. All the patients were diagnosed of breast cancer and treated with primary chemotherapy. All the patients underwent total axillary dissection. At 24 hours of the intervention, all patients received one dose of 37 MBq (1 mCi) of 99mTc labeled macroaggregated albumin (MAA) in the center of the lesion by ultrasonographic guide. Scintigraphic images were performed in anterior and lateral projections (in prone decubitus with hanging breast) to verify the correct location of the radiopharmaceutical. After, a study of the SN was performed by subdermal administration of an 18 MBq (0.5 mCi) dose of 99mTc labeled nanocolloid. The SN site was labeled on the skin with indelible ink. The intrasurgical site of the breast lesion and SN was performed using a gamma detector probe. Correct placement of the intralesional radiopharmaceutical, existence of disease free borders and histological study of SN were performed by the pathologist in the surgical act. The differed pathology study was performed with hematoxilin-eosin and immunohistochemistry. Result: In 29 of the 31 lesion sites, there was good placement of the radiotracer (93.5 %). There was 1 case of contamination of the needle pathway and another that did not coincide with the lesion, due to poor placement. Location of the SN was 96 % in the axilla and 4 % in axilla and internal mammary chain. The SN was located in surgery in 28/31 patients (90 %). Conclusion: Simultaneous radioguided location of the hidden breast lesions and sentinel node is a simple method, which is well tolerated by the patients and can be done in a single operation act.
Keywords:
Primary chemotherapy
Breast cancer
Sentinel node

Artículo

Opciones para acceder a los textos completos de la publicación Revista Española de Medicina Nuclear e Imagen Molecular
Socio
Si es usted socio de la Sociedad Española de Medicina Nuclear e Imagen Molecular (SEMNIM) puede acceder al texto completo de los contenidos de la Revista Española de Medicina Nuclear e Imagen Molecular desde los enlaces a la revista publicados en la web de la SEMNIN (enlace a https://semnim.es/iniciar-sesion/), previo inicio de sesión como socio. Si tiene problemas de acceso puede contactar con la Secretaría Técnica de la SEMNIM en el correo electrónico secretaria.tecnica@semnim.es o en el teléfono: + 34 619 594 780
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Revista Española de Medicina Nuclear e Imagen Molecular

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos