metricas
covid
Buscar en
Revista Española de Medicina Nuclear e Imagen Molecular
Toda la web
Inicio Revista Española de Medicina Nuclear e Imagen Molecular Radiomarcaje y estudios de biodistribución de nanopartículas poliméricas como...
Información de la revista
Vol. 32. Núm. 2.
Páginas 92-97 (marzo - abril 2013)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Visitas
2643
Vol. 32. Núm. 2.
Páginas 92-97 (marzo - abril 2013)
Original
Radiomarcaje y estudios de biodistribución de nanopartículas poliméricas como adyuvantes para la vacunación oftálmica frente a la brucelosis
Radiolabeling and biodistribution studies of polymeric nanoparticles as adjuvants for ocular vaccination against brucellosis
Visitas
2643
M. Sánchez-Martíneza, R. da Costa Martinsb, G. Quincocesa, C. Gamazoc, C. Caicedod, J.M. Iracheb, I. Peñuelasa,e,
Autor para correspondencia
ipenuelas@unav.es
ivpenuelas@gmail.com

Autor para correspondencia.
a Unidad de Radiofarmacia, Departamento de Medicina Nuclear, Clínica Universidad de Navarra, Pamplona, España
b Departamento de Farmacia y Tecnología Farmacéutica, Universidad de Navarra, Pamplona, España
c Departamento de Microbiología, Universidad de Navarra, Pamplona, España
d Departamento de Medicina Nuclear, Clínica Universidad de Navarra, Pamplona, España
e Unidad de Investigación Micro-PET, Centro de Investigación Médica Aplicada-Clínica Universidad de Navarra, Pamplona, España
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (4)
Mostrar másMostrar menos
Resumen
Objetivo

Optimizar el radiomarcaje con 99mTc de nanopartículas de Gantrez® manosiladas y cargadas con el antígeno de Brucella ovis (Man-NP-HS) y llevar a cabo estudios de biodistribución en un ratón tras la administración de las nanopartículas por vía ocular.

Material y métodos

Las Man-NP-HS se obtuvieron por el método de desplazamiento del disolvente. Se purificaron, liofilizaron y caracterizaron. A continuación, se marcaron con 74MBq de 99mTcO4 previamente reducido con una disolución ácida de cloruro de estaño, trabajando en ausencia de oxígeno y con un pH final de 4. El rendimiento del marcaje se evaluó mediante TLC. Los estudios de biodistribución se llevaron a cabo en ratones tras la administración oftálmica de la formulación y de un control de 99mTcO4 libre. Para ello, se sacrificaron los animales a las 2 y a las 24h tras la administración ocular y se contaron los órganos en un contador gamma.

Resultados

Se obtuvo un rendimiento de marcaje superior al 90%. Los estudios de biodistribución de 99mTc-Man-NP-HS permitieron detectar la actividad concentrada en la mucosa nasal y ocular y el tracto gastrointestinal tanto a las 2 como a las 24h frente a la biodistribución de 99mTcO4 libre que permaneció concentrado en la piel alrededor del ojo y en el tracto gastrointestinal.

Conclusión

Los estudios de biodistribución de 99mTc-Man-NP-HS tras la administración oftálmica han permitido demostrar su biodistribución en las mucosas y el tracto gastrointestinal, característica indispensable como sistema de liberación de antígenos a través de la mucosa ocular. Esto, junto con su elevada respuesta inmune, efectiva protección y no virulencia, convierte a estas nanopartículas en una vacuna ideal antibrucelosis.

Palabras clave:
Nanopartículas
Biodistribución
Brucelosis
Vacunación ocular
Abstract
Purpose

To optimize radiolabeling with 99mTc of mannosylated Gantrez® nanoparticles loaded with the Brucella Ovis antigen (Man-NP-HS) and to carry out biodistribution studies in mice after ocular administration of the nanoparticles.

Material and methods

Man-NP-HS nanoparticles were prepared by the solvent displacement method. They were purified, lyophilized and characterized. Following this, they were radiolabeled with 74 MBq of 99mTcO4 previously reduced with an acidic stannous chloride solution, working in absence of oxygen and at a final pH of 4. Radiolabeling yield was evaluated by TLC. Biodistribution studies were carried out in mice after ocular administration of the formulation and control of free 99mTcO4. To do so, the animals were humanely killed at 2 and 24hours after the ocular administration and activity in organs was measured in a Gamma counter.

Results

Radiolabeling yield obtained was greater than 90%. Biodistribution studies of 99mTc-Man-NP-HS showed radioactivity accumulated at 2 and 24hours in nasal and ocular mucosa and gastrointestinal tract, in contrast to biodistribution of free 99mTcO4 that remained concentrated in the skin around the eye and gastrointestinal tract.

Conclusion

Biodistribution studies of 99mTc-Man-NP-HS after ocular instillation have made it possible to demonstrate its biodistribution in nasal mucosa and gastrointestinal tract. This characteristic is essential as an antigenic delivery system throughout the ocular mucosa. This, together with its elevated immune response, effective protection and intrinsic avirulence make them a suitable anti-Brucella vaccine candidate.

Keywords:
Nanoparticles
Biodistribution
Brucellosis
Ocular vaccination

Artículo

Opciones para acceder a los textos completos de la publicación Revista Española de Medicina Nuclear e Imagen Molecular
Socio
Si es usted socio de la Sociedad Española de Medicina Nuclear e Imagen Molecular (SEMNIM) puede acceder al texto completo de los contenidos de la Revista Española de Medicina Nuclear e Imagen Molecular desde los enlaces a la revista publicados en la web de la SEMNIN (enlace a https://semnim.es/iniciar-sesion/), previo inicio de sesión como socio. Si tiene problemas de acceso puede contactar con la Secretaría Técnica de la SEMNIM en el correo electrónico secretaria.tecnica@semnim.es o en el teléfono: + 34 619 594 780
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Revista Española de Medicina Nuclear e Imagen Molecular

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos