array:24 [ "pii" => "S2341192917301580" "issn" => "23411929" "doi" => "10.1016/j.redare.2017.09.008" "estado" => "S300" "fechaPublicacion" => "2017-12-01" "aid" => "831" "copyrightAnyo" => "2017" "documento" => "simple-article" "crossmark" => 1 "subdocumento" => "cor" "cita" => "Revista Española de Anestesiología y Reanimación (English Version). 2017;64:601" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:2 [ "total" => 2 "HTML" => 2 ] "Traduccion" => array:1 [ "es" => array:18 [ "pii" => "S0034935617301342" "issn" => "00349356" "doi" => "10.1016/j.redar.2017.05.001" "estado" => "S300" "fechaPublicacion" => "2017-12-01" "aid" => "831" "documento" => "simple-article" "crossmark" => 1 "subdocumento" => "cor" "cita" => "Rev Esp Anestesiol Reanim. 2017;64:601" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:2 [ "total" => 99 "formatos" => array:2 [ "HTML" => 93 "PDF" => 6 ] ] "es" => array:10 [ "idiomaDefecto" => true "cabecera" => "<span class="elsevierStyleTextfn">Carta al Director</span>" "titulo" => "Respuesta a la carta: Contestación a la carta «Actuación ante un caso de extubación accidental con paciente en posición de decúbito prono»" "tienePdf" => "es" "tieneTextoCompleto" => "es" "paginas" => array:1 [ 0 => array:1 [ "paginaInicial" => "601" ] ] "titulosAlternativos" => array:1 [ "en" => array:1 [ "titulo" => "Reply to letter: Response to the letter «Anaesthesia management of accidental extubation in the prone position»" ] ] "contieneTextoCompleto" => array:1 [ "es" => true ] "contienePdf" => array:1 [ "es" => true ] "autores" => array:1 [ 0 => array:2 [ "autoresLista" => "L. Bosch, M. Sadurní, S. Pacreu" "autores" => array:3 [ 0 => array:2 [ "nombre" => "L." "apellidos" => "Bosch" ] 1 => array:2 [ "nombre" => "M." "apellidos" => "Sadurní" ] 2 => array:2 [ "nombre" => "S." "apellidos" => "Pacreu" ] ] ] ] ] "idiomaDefecto" => "es" "Traduccion" => array:1 [ "en" => array:9 [ "pii" => "S2341192917301580" "doi" => "10.1016/j.redare.2017.09.008" "estado" => "S300" "subdocumento" => "" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:1 [ "total" => 0 ] "idiomaDefecto" => "en" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S2341192917301580?idApp=UINPBA00004N" ] ] "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0034935617301342?idApp=UINPBA00004N" "url" => "/00349356/0000006400000010/v1_201711141119/S0034935617301342/v1_201711141119/es/main.assets" ] ] "itemSiguiente" => array:19 [ "pii" => "S2341192917301609" "issn" => "23411929" "doi" => "10.1016/j.redare.2017.09.010" "estado" => "S300" "fechaPublicacion" => "2017-12-01" "aid" => "833" "copyright" => "Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor" "documento" => "simple-article" "crossmark" => 1 "subdocumento" => "cor" "cita" => "Revista Española de Anestesiología y Reanimación (English Version). 2017;64:602-3" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:2 [ "total" => 1 "HTML" => 1 ] "en" => array:10 [ "idiomaDefecto" => true "cabecera" => "<span class="elsevierStyleTextfn">Letter to the Director</span>" "titulo" => "Is there a real consensus among anesthetists and surgeons about the neuromuscular block? Methodological considerations about the ACHILLES study" "tienePdf" => "en" "tieneTextoCompleto" => "en" "paginas" => array:1 [ 0 => array:2 [ "paginaInicial" => "602" "paginaFinal" => "603" ] ] "titulosAlternativos" => array:1 [ "es" => array:1 [ "titulo" => "¿Existe realmente consenso entre los anestesistas y los cirujanos sobre el bloqueo neuromuscular?: consideraciones metodológicas sobre el estudio AQUILES" ] ] "contieneTextoCompleto" => array:1 [ "en" => true ] "contienePdf" => array:1 [ "en" => true ] "autores" => array:1 [ 0 => array:2 [ "autoresLista" => "A. Nicolau Gozalbo, L. Vives Piqueres" "autores" => array:2 [ 0 => array:2 [ "nombre" => "A." "apellidos" => "Nicolau Gozalbo" ] 1 => array:2 [ "nombre" => "L." "apellidos" => "Vives Piqueres" ] ] ] ] ] "idiomaDefecto" => "en" "Traduccion" => array:1 [ "es" => array:9 [ "pii" => "S0034935617301366" "doi" => "10.1016/j.redar.2017.05.003" "estado" => "S300" "subdocumento" => "" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:1 [ "total" => 0 ] "idiomaDefecto" => "es" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0034935617301366?idApp=UINPBA00004N" ] ] "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S2341192917301609?idApp=UINPBA00004N" "url" => "/23411929/0000006400000010/v1_201711240853/S2341192917301609/v1_201711240853/en/main.assets" ] "itemAnterior" => array:19 [ "pii" => "S2341192917301579" "issn" => "23411929" "doi" => "10.1016/j.redare.2017.09.007" "estado" => "S300" "fechaPublicacion" => "2017-12-01" "aid" => "830" "copyright" => "Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor" "documento" => "simple-article" "crossmark" => 1 "subdocumento" => "cor" "cita" => "Revista Española de Anestesiología y Reanimación (English Version). 2017;64:600-1" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:2 [ "total" => 3 "HTML" => 3 ] "en" => array:10 [ "idiomaDefecto" => true "cabecera" => "<span class="elsevierStyleTextfn">Letter to the Director</span>" "titulo" => "Response to the letter: Anaesthesia management of accidental extubation in the prone position" "tienePdf" => "en" "tieneTextoCompleto" => "en" "paginas" => array:1 [ 0 => array:2 [ "paginaInicial" => "600" "paginaFinal" => "601" ] ] "titulosAlternativos" => array:1 [ "es" => array:1 [ "titulo" => "Comentarios a la carta: Actuación ante un caso de extubación accidental con paciente en posición de decúbito prono" ] ] "contieneTextoCompleto" => array:1 [ "en" => true ] "contienePdf" => array:1 [ "en" => true ] "autores" => array:1 [ 0 => array:2 [ "autoresLista" => "J. Benatar-Haserfaty" "autores" => array:1 [ 0 => array:2 [ "nombre" => "J." "apellidos" => "Benatar-Haserfaty" ] ] ] ] ] "idiomaDefecto" => "en" "Traduccion" => array:1 [ "es" => array:9 [ "pii" => "S0034935617301330" "doi" => "10.1016/j.redar.2017.04.006" "estado" => "S300" "subdocumento" => "" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:1 [ "total" => 0 ] "idiomaDefecto" => "es" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0034935617301330?idApp=UINPBA00004N" ] ] "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S2341192917301579?idApp=UINPBA00004N" "url" => "/23411929/0000006400000010/v1_201711240853/S2341192917301579/v1_201711240853/en/main.assets" ] "asociados" => array:1 [ 0 => array:19 [ "pii" => "S2341192917301579" "issn" => "23411929" "doi" => "10.1016/j.redare.2017.09.007" "estado" => "S300" "fechaPublicacion" => "2017-12-01" "aid" => "830" "copyright" => "Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor" "documento" => "simple-article" "crossmark" => 1 "subdocumento" => "cor" "cita" => "Revista Española de Anestesiología y Reanimación (English Version). 2017;64:600-1" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:2 [ "total" => 3 "HTML" => 3 ] "en" => array:10 [ "idiomaDefecto" => true "cabecera" => "<span class="elsevierStyleTextfn">Letter to the Director</span>" "titulo" => "Response to the letter: Anaesthesia management of accidental extubation in the prone position" "tienePdf" => "en" "tieneTextoCompleto" => "en" "paginas" => array:1 [ 0 => array:2 [ "paginaInicial" => "600" "paginaFinal" => "601" ] ] "titulosAlternativos" => array:1 [ "es" => array:1 [ "titulo" => "Comentarios a la carta: Actuación ante un caso de extubación accidental con paciente en posición de decúbito prono" ] ] "contieneTextoCompleto" => array:1 [ "en" => true ] "contienePdf" => array:1 [ "en" => true ] "autores" => array:1 [ 0 => array:2 [ "autoresLista" => "J. Benatar-Haserfaty" "autores" => array:1 [ 0 => array:2 [ "nombre" => "J." "apellidos" => "Benatar-Haserfaty" ] ] ] ] ] "idiomaDefecto" => "en" "Traduccion" => array:1 [ "es" => array:9 [ "pii" => "S0034935617301330" "doi" => "10.1016/j.redar.2017.04.006" "estado" => "S300" "subdocumento" => "" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:1 [ "total" => 0 ] "idiomaDefecto" => "es" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0034935617301330?idApp=UINPBA00004N" ] ] "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S2341192917301579?idApp=UINPBA00004N" "url" => "/23411929/0000006400000010/v1_201711240853/S2341192917301579/v1_201711240853/en/main.assets" ] ] "en" => array:13 [ "idiomaDefecto" => true "cabecera" => "<span class="elsevierStyleTextfn">Letter to the Editor</span>" "titulo" => "Reply to letter: Response to the letter “Anaesthesia management of accidental extubation in the prone position”" "tieneTextoCompleto" => true "saludo" => "To the Editor," "paginas" => array:1 [ 0 => array:1 [ "paginaInicial" => "601" ] ] "autores" => array:1 [ 0 => array:4 [ "autoresLista" => "L. Bosch, M. Sadurní, S. Pacreu" "autores" => array:3 [ 0 => array:4 [ "nombre" => "L." "apellidos" => "Bosch" "email" => array:1 [ 0 => "laiaboschduran@gmail.com" ] "referencia" => array:1 [ 0 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">*</span>" "identificador" => "cor0005" ] ] ] 1 => array:2 [ "nombre" => "M." "apellidos" => "Sadurní" ] 2 => array:2 [ "nombre" => "S." "apellidos" => "Pacreu" ] ] "afiliaciones" => array:1 [ 0 => array:2 [ "entidad" => "Servicio de Anestesiología y Reanimación, Parc de Salut Mar, Barcelona, Spain" "identificador" => "aff0005" ] ] "correspondencia" => array:1 [ 0 => array:3 [ "identificador" => "cor0005" "etiqueta" => "⁎" "correspondencia" => "Corresponding author." ] ] ] ] "titulosAlternativos" => array:1 [ "es" => array:1 [ "titulo" => "Respuesta a la carta: Contestación a la carta «Actuación ante un caso de extubación accidental con paciente en posición de decúbito prono»" ] ] "textoCompleto" => "<span class="elsevierStyleSections"><p id="par0005" class="elsevierStylePara elsevierViewall">We thank Benatar et al. for their interest in our article, and for their comments, and take this opportunity to comment on some of their observations.</p><p id="par0010" class="elsevierStylePara elsevierViewall">According to the literature, repositioning the patient in the supine position may not be necessary as a first option.<a class="elsevierStyleCrossRefs" href="#bib0030"><span class="elsevierStyleSup">1–4</span></a> This is because securing the airway with a laryngeal mask airway (LMA) while the patient remains prone is an effective strategy. In all 3 published cases describing the emergency placement of a laryngeal mask due to accidental extubation in the prone position,<a class="elsevierStyleCrossRefs" href="#bib0030"><span class="elsevierStyleSup">1–3</span></a> the authors recommend this strategy as the first line of treatment, because in the prone position the soft tissues of the oropharynx are easily displaced, facilitating placement of the LMA.<a class="elsevierStyleCrossRef" href="#bib0040"><span class="elsevierStyleSup">3</span></a> Spond et al.<a class="elsevierStyleCrossRef" href="#bib0050"><span class="elsevierStyleSup">5</span></a> recently published a case of accidental extubation in a patient with Klippel–Feil syndrome, and recommend a preoperative briefing on the steps to be taken in the case of accidental extubation. These authors suggest the LMA as the first option, provided the patient does not meet difficult airway (DA) criteria.</p><p id="par0015" class="elsevierStylePara elsevierViewall">Turning the patient supine is not without its risks. Exposure of the dura mater during surgery drastically increases the risk of infection at the surgical site. Furthermore, during placement of spinal instrumentation, turning a patient may compromise the stability of the spine and result in paraplegia.<a class="elsevierStyleCrossRef" href="#bib0040"><span class="elsevierStyleSup">3</span></a></p><p id="par0020" class="elsevierStylePara elsevierViewall">We fully agree with the authors that fibre optic intubation in the prone patient has its limitations, insofar as it is not the ideal position for this technique and the manoeuvre is time-consuming, given the urgency of the situation. In fact, we could be critised for wasting time in attempting to replace the orotracheal tube under fibreoptic vision. This triggered cardiac arrest due to hypoxaemia, despite successful placement of the Fastrach<span class="elsevierStyleSup">®</span> laryngeal mask.</p><p id="par0025" class="elsevierStylePara elsevierViewall">Since accidental extubation in the prone position is an emergency situation, we designed our algorithm to serve as a plan of action to facilitate decision making by differentiating between DA and normal airway. We agree that, in patients with DA, it is reasonable to turn the patient to the supine position.</p><p id="par0030" class="elsevierStylePara elsevierViewall">We believe the decision should be based on the characteristics of the patient and the context in which extubation occurs, with the ultimate objective being to act rapidly to ensure patient safety.</p></span>" "pdfFichero" => "main.pdf" "tienePdf" => true "NotaPie" => array:1 [ 0 => array:2 [ "etiqueta" => "☆" "nota" => "<p class="elsevierStyleNotepara" id="npar0005">Please cite this article as: Bosch L, Sadurní M, Pacreu S. Respuesta a la carta: Contestación a la carta «Actuación ante un caso de extubación accidental con paciente en posición de decúbito prono». Rev Esp Anestesiol Reanim. 2017;64:601.</p>" ] ] "bibliografia" => array:2 [ "titulo" => "References" "seccion" => array:1 [ 0 => array:2 [ "identificador" => "bibs0015" "bibliografiaReferencia" => array:5 [ 0 => array:3 [ "identificador" => "bib0030" "etiqueta" => "1" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "An unusual case of airway rescue in prone position with the ProSeal laryngeal mask airway" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:2 [ 0 => "J. Brimacombe" 1 => "C. Keller" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:4 [ "tituloSerie" => "Can J Anesthesia" "fecha" => "2005" "volumen" => "52" "paginaInicial" => "884" ] ] ] ] ] ] 1 => array:3 [ "identificador" => "bib0035" "etiqueta" => "2" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Emergency airway management with a laryngeal mask airway in a patient placed in prone position" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:3 [ 0 => "J. Raphael" 1 => "T. Rosenthal-Ganon" 2 => "Y. Gozal" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1016/j.jclinane.2004.03.004" "Revista" => array:6 [ "tituloSerie" => "J Clin Anesth" "fecha" => "2004" "volumen" => "16" "paginaInicial" => "560" "paginaFinal" => "561" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/15590266" "web" => "Medline" ] ] ] ] ] ] ] ] 2 => array:3 [ "identificador" => "bib0040" "etiqueta" => "3" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "The use of a laryngeal mask airway for emergent airway management in a prone child" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:3 [ 0 => "R.S. Dingeman" 1 => "L.C. Goumnerova" 2 => "S.M. Goobie" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1213/01.ANE.0000146512.48688.FA" "Revista" => array:6 [ "tituloSerie" => "Anesth Analg" "fecha" => "2005" "volumen" => "100" "paginaInicial" => "670" "paginaFinal" => "671" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/15728049" "web" => "Medline" ] ] ] ] ] ] ] ] 3 => array:3 [ "identificador" => "bib0045" "etiqueta" => "4" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Accidental tracheal extubation of a patient in the prone position" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:3 [ 0 => "D. Thiel" 1 => "J. Houten" 2 => "M. Wecksell" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1097/ACC.0b013e3182a528aa" "Revista" => array:6 [ "tituloSerie" => "A A Case Rep" "fecha" => "2015" "volumen" => "2" "paginaInicial" => "20" "paginaFinal" => "22" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/25611046" "web" => "Medline" ] ] ] ] ] ] ] ] 4 => array:3 [ "identificador" => "bib0050" "etiqueta" => "5" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Crisis management of accidental extubation in a prone-positioned patient with Klippel–Feil syndrome" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:4 [ 0 => "M. Spond" 1 => "T. Burns" 2 => "T. Rosenbaum" 3 => "K. Lienhart" ] ] ] ] ] "host" => array:1 [ 0 => array:1 [ "Revista" => array:5 [ "tituloSerie" => "Anesth Analg Case Rep" "fecha" => "2016" "volumen" => "6" "paginaInicial" => "383" "paginaFinal" => "386" ] ] ] ] ] ] ] ] ] ] ] "idiomaDefecto" => "en" "url" => "/23411929/0000006400000010/v1_201711240853/S2341192917301580/v1_201711240853/en/main.assets" "Apartado" => array:4 [ "identificador" => "70434" "tipo" => "SECCION" "en" => array:2 [ "titulo" => "Letters to the Director" "idiomaDefecto" => true ] "idiomaDefecto" => "en" ] "PDF" => "https://static.elsevier.es/multimedia/23411929/0000006400000010/v1_201711240853/S2341192917301580/v1_201711240853/en/main.pdf?idApp=UINPBA00004N&text.app=https://www.elsevier.es/" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S2341192917301580?idApp=UINPBA00004N" ]
Journal Information
Share
Download PDF
More article options
Letter to the Editor
Reply to letter: Response to the letter “Anaesthesia management of accidental extubation in the prone position”
Respuesta a la carta: Contestación a la carta «Actuación ante un caso de extubación accidental con paciente en posición de decúbito prono»
Servicio de Anestesiología y Reanimación, Parc de Salut Mar, Barcelona, Spain
Related content
Revista Española de Anestesiología y Reanimación (English Version). 2017;64:600-110.1016/j.redare.2017.09.007
J. Benatar-Haserfaty