Cribado auditivo neonatal con potenciales evocados auditivos de estado estable a múltiples frecuencias
Newborn hearing screening test with multiple auditory steady-state responses
Visitas
9256
Eleina Mijares Nodarsea, Didiesle Herrera Alonsoa, José Gaya Vázqueza,
Autor para correspondencia
gaya@cneuro.edu.cu

Autor para correspondencia.
, Elsa Santos Feblesa, María Cecilia Pérez Abaloa, Leonel Mendez Alarcónb, Regla Robertson Terryb
a Departamento de Audición y Lenguaje, Centro de Neurociencias de Cuba, La Habana, Cuba
b Servicio de Neonatología, Hospital Materno Dr. Eusebio Hernández, La Habana, Cuba
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (4)
Mostrar másMostrar menos
Tablas (1)
Tabla 1. Eficiencia diagnóstica del sistema semiautomático de cribado auditivo neonatal
Resumen
Introducción

Las técnicas más utilizadas en los programas de cribado auditivo presentan limitaciones reconocidas en la detección de las pérdidas auditivas. Se presenta una nueva alternativa de cribado auditivo basada en el uso de potenciales evocados de estado estable.

Objetivo

Evaluar la factibilidad de una prueba semiautomática de cribado auditivo en una población de recién nacidos sanos.

Métodos

Se estudiaron 50 neonatos (7-18 días de nacidos) sin factores clínicos de riesgo y con respuesta detectable bilateral a 40 db nHL con potenciales evocados auditivos de tronco cerebral. A cada uno se le realizó una prueba con potenciales evocados auditivos de estado estable a múltiples frecuencias (PEAee-MF) (500 y 2.000Hz) y un registro sin estímulo para simulación de sordera.

Resultados

Los umbrales auditivos se encontraron entre 25 y 50dB HL para ambas frecuencias (42,5±7dB HL para 500Hz y 35,5±6dB HL para 2.000Hz). Los tiempos medios de registro fueron de 2,6±1,6min por cada oído y la duración total del procedimiento (incluyendo preparación y colocación de electrodos) fue de 17,8±3,7min. Con la prueba de cribado se obtuvo una adecuada eficiencia diagnóstica (sensibilidad, 100%, y especificidad, 96%).

Conclusiones

Los resultados descritos sugieren que los PEAee-MF (estimulación simultánea con múltiples frecuencias) pudieran ser utilizados como prueba de cribado auditivo en una población de recién nacidos sanos. Para esto, es necesario seguir perfeccionando la técnica combinando una metodología válida y sencilla con determinadas facilidades de automatización.

Palabras clave:
Cribado auditivo neonatal
Pérdida auditiva
Potenciales evocados auditivos de estado estable
Abstract
Introduction

The techniques most frequently used within a screening context (otoacoustic emissions and click auditory brainstem response) have well-known limitations in hearing loss detection.

Objective

This study examines the feasibility of a semi-automated multiple auditory steady-state responses (MSSR) system designed for neonatal hearing screening.

Methods

A sample of 50 newborns without risk factors (well-babies) was tested within two weeks of birth. All had detectable auditory brainstem responses to clicks down to 40dB nHL in both ears. Two amplitude modulated carrier tones of 500 and 2,000Hz were mixed together and presented simultaneously. Each infant (and ear) was screened with the MSSR system; to simulate a hearing loss, a recording without stimulation was also obtained.

Results

Mean auditory thresholds were 42.5±7dB HL at 500Hz and 35.5±6dB HL at 2,000Hz. The average duration of the MSSR recording was 2.6±1.6minutes for each tested ear and the overall duration of the screening procedure (including electrode fitting and infant preparation) was 17.8±3.7minutes. The diagnostic sensibility and the positive predictive values of the MSSR semi-automatic screening system was 100% and 96% respectively, with specificity of 96% and negative predictive values of 100%.

Conclusions

Although the diagnostic efficiency of the semi-automated MSSR system was found adequate, further technological improvements are still necessary to facilitate its use in the context of universal newborn hearing screening program.

Keywords:
Auditory steady-state response
Hearing loss
Neonatal hearing screening

Artículo

Opciones para acceder a los textos completos de la publicación Acta Otorrinolaringológica Española
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Acta Otorrinolaringológica Española

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos