metricas
covid
Buscar en
Archivos de la Sociedad Española de Oftalmología
Toda la web
Inicio Archivos de la Sociedad Española de Oftalmología Resultados quirúrgicos de la esotropía adquirida comitante aguda. Causas y cla...
Información de la revista
Vol. 97. Núm. 10.
Páginas 558-564 (octubre 2022)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Visitas
183
Vol. 97. Núm. 10.
Páginas 558-564 (octubre 2022)
Artículo original
Resultados quirúrgicos de la esotropía adquirida comitante aguda. Causas y clasificación
Surgical outcomes of acquired acute comitant esotropia. Causes and classification
Visitas
183
P. Merinoa,
Autor para correspondencia
pilimerino@gmail.com

Autora para correspondencia.
, M. Freirea, J. Yáñez-Merinob, P. Gómez de Liañoa
a Ocular Motility Section, Department of Ophthalmology, Hospital Gregorio Marañón, Madrid, España
b Departamento de Oftalmología, Hospital Miguel Servet, Zaragoza, España
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Resumen
Objetivo

Estudiar los resultados del tratamiento quirúrgico de las esotropías comitantes adquiridas y analizar sus posibles causas.

Métodos

Estudio retrospectivo de pacientes operados de esotropía aguda comitante desde 2017-2021. Se analizó la desviación horizontal de lejos y cerca, el equivalente esférico, y uso excesivo de tablets y smartphones. Se consideró buen resultado sensorial la presencia de estereopsis y motor si la deviación era10 dioptrías prismáticas (dp), y sin diplopía al final del seguimiento.

Resultados

Se incluyeron 15 casos (60% mujeres), edad media: 29,07 años (el 86,66%16 años). El tiempo medio desde el inicio de los síntomas hasta la cirugía: 23,3 meses. La media de la desviación horizontal preoperatoria fue de 19,73±7,2dp de cerca y 22,93±7,3 dp de lejos, disminuyendo al final del seguimiento a 3,33±3,8dp de cerca y 3,86±3,9dp de lejos (p<0,001). Un 66,6% refería diplopía. Un 46,66% tenían esoforias o microestrabismos descompensados, un 86,66% miopía y el 33,33% refería uso excesivo de tablets y smartphones. En 10 casos se realizó retroceso de rectos medios. El resultado motor fue bueno en un 93,33% de los casos y sensorial en 46,66%, con desaparición de la diplopía.

Conclusiones

La cirugía fue un excelente tratamiento para resolver la desviación y la diplopía. Las esoforias y los microestrabismos representaron casi la mitad de los casos y el excesivo uso de tablets y smartphones la tercera parte de la muestra. La mayoría de los sujetos eran miopes.

Palabras clave:
Esotropía adquirida comitante
Diplopía
Tablets y smartphones
Miopía
Microestrabismo y esoforia descompensada
Abstract
Purpose

To study the results of surgical treatment of acquired concomitant esotropia and its posible causes.

Methods

Retrospective study of the patients with acute acquired esotropia that were operated on since 2017 to 2021. Distance and near horizontal deviation, spherical equivalent and the excessive use of the tablets and smartphones were analyzed. A good sensorial outcome was considered when stereopsis was recovered and good motor outcome if horizontal deviation was10 prism diopters (pd) at the end of the follow-up.

Results

A total of 15 cases were included (60% women), mean age: 29.07 years (86.66%16 years). Mean time since the beginning of the symptoms to the surgery was 23.3 months. Mean horizontal preoperative deviation was 19.73±7.2pd at near and 22.93±7.3dp at distance decreasing to 3.33±3.8pd at near and 3.86±3.9pd at distance (P<.001). The 66.6% had diplopia. The 46.66% had decompensated esophoria or microesotropia, 86,66% myopia and the 33.33% referred excesive use of the tablets and smartphones. The medial rectus recession were done in 10 cases. A good motor outcome was obtained in the 93.33% of the cases and sensorial outcome in the 46.66% without diplopía.

Conclusion

Surgery was an excellent treatment to resolve the deviation and diplopia. The esophorias and microesotropias represented near the half of the cases and the excesive use of the tablets and smartphones were the third part of the sample. Most of the patients had myopia.

Keywords:
Acquired comitant esotropia
Diplopia
Tablets and smartphones
Myopia
Decompensated esophorias and microesotropias

Artículo

Opciones para acceder a los textos completos de la publicación Archivos de la Sociedad Española de Oftalmología
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Archivos de la Sociedad Española de Oftalmología

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos