Recent advances in surgical techniques have trended toward minimally invasive procedures. Currently, a laparoscopic approach has become the gold standard for splenectomy because it is an effective, reliable technique requiring a shorter hospitalization period with fewer surgical complications, less morbidity, and better esthetic results (1). However, as the number of ports increases in laparoscopy, there is an increase in the incidence of morbidity, including port entrance hernias and infection, internal organ injury, poorer esthetic results, and most importantly, bleeding. Morbidity resulting from the use of multiple ports has prompted the development of techniques using fewer ports (2).
Herein, we demonstrate the applicability of glove port single-incision laparoscopy, with a review of the surgical literature.
CASE DESCRIPTIONA 33-year-old female who initially presented with spontaneous nosebleeds was diagnosed with immune thrombocytopenic purpura (ITP) and had been followed for two years. After the patient developed steroid resistance, a splenectomy was planned. She had previously undergone surgery for a perforated peptic ulcer. A physical examination identified a midline incision scar above the abdomen. Ultrasonography indicated that the spleen was of normal size. No intravenous antibiotics were administered preoperatively. The patient was treated with cortisol for the surgery.
SURGICAL TECHNIQUEWith the patient in the 30° right lateral decubitus position, the abdominal cavity was entered through a 22-mm incision parallel to the skin folds at the left midclavicular line. A surgical glove port was formed using an extra-small ALEXIS wound protector (Applied Medical, Rancho Santa Margarita, CA, USA) and a size 7.5 standard surgical glove (Figures 1 and 2). One 12-mm and two 5-mm trocars were placed through incisions made in the glove fingers. Following CO2 insufflation, adhesions around the gastrosplenic ligament, which were caused by the previous peptic ulcer surgery, were dissected using an ultrasonic dissector. The spleen was suspended with a SILS clinch 36 grasper (Covidien, Mansfield, MA, USA) and dissected from its ligaments with the help of a harmonic dissector. After the hilum of the spleen was exposed, it was cut using an Endo-GIA II stapler (60-mm long, 2.5-mm staples, Auto Suture; US Surgical, Norwalk, CT) (Figure 3). The spleen was placed in a 15-mm bag (EndoCatch II, Autosuture, Covidien, Mansfield, MA, USA) (Figure 4), crushed, and removed from the abdominal cavity through the ALEXIS port. The procedure took 45 min. No intraoperative complications occurred during surgery.
The patient developed tachycardia on the second postoperative day, and her hemoglobin level decreased. Computed tomography showed a hematoma initiating where the spleen had been removed and extending to the pelvis. The patient then underwent a second surgery. With the patient in the same position, another surgical glove port was made, and the abdomen was explored. Bleeding was discovered at the vascular stapler line. The bleeding was sutured laparoscopically. After the intra-abdominal hematoma was drained, the abdominal cavity was irrigated. Finally, a drain was placed at the previous location of the spleen. The patient was discharged from the hospital on the third postoperative day. The pathology report showed congested splenectomy material consistent with ITP.
DISCUSSIONSingle-port laparoscopy has been adapted to many surgical procedures (2-8). Other studies have demonstrated that laparoscopic splenectomy can be performed using only one incision (8-11). The advantages of the surgical glove port technique compared to the single-port technique include its ease of placement and use of inexpensive surgical equipment (12,13). The cost difference between these two techniques is an important factor, particularly in developing countries. Additionally, the surgical glove port technique ensures a safer entry while placing the port, and the surgeon has more mobility with the glove port technique than with the single-port technique. However, manipulations performed laparoscopically through a single port are more difficult compared with a standard laparoscopic approach.
More trocars can be placed through the glove fingers by making wider incisions as necessary. In this case, because of previous peptic ulcer surgery, an incision in the hypochondrium was preferred to a transumbilical entry. Consequently, the adhesions resulting from the previous operation posed no problems. A transumbilical entry may be a better esthetic choice in patients with no intraabdominal adhesions. We believe that a transumbilical incision would not cause any technical difficulties.
Another advantage of the surgical glove port compared with the standard laparoscopic splenectomy is that there is no need for a new incision or to enlarge the existing incision to remove the spleen from the abdomen. The disadvantages of this technique include punctures in the glove or ALEXIS port and gas leakage during the surgery. However, these problems are easily resolved during the procedure. In our case, the subsequent hemorrhage was easily treated using the glove-port technique. Although most new techniques are typically more expensive than established techniques, the glove port technique uses less costly, more widely available surgical equipment (12).
No potential conflict of interest was reported.
Erkin I was the primary surgeon. Cihangir A was the second surgeon and was responsible for writing the manuscript. Basceken SI was the assistant surgeon and co-writer. Tantoglu U and Kayılıoglu I were co-writers. Cakmak A is the head of the Laparoscopic Surgery Unit and co-writer.