metricas
covid
Buscar en
Clinics
Toda la web
Inicio Clinics Sentinel lymph node biopsy in oral cavity cancer using indocyanine green: A syst...
Información de la revista
Vol. 76.
(enero 2020)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Visitas
1791
Vol. 76.
(enero 2020)
REVIEW ARTICLE
Open Access
Sentinel lymph node biopsy in oral cavity cancer using indocyanine green: A systematic review and meta-analysis
Visitas
1791
Yongfeng ChenI,#, Qi XiaoII,#, Weina ZouII, Chengwan XiaII, Hongling YinII, Yumei PuII, Yuxin WangII,
Autor para correspondencia
wangyuxin0212@126.com

Corresponding authors.
, Kai ZhangI,
Autor para correspondencia
zk29788@163.com

Corresponding authors.
I Department of Stomatology, The First Affiliated Hospital of Bengbu Medical College, Bengbu, China.
II Department of Oral and Maxillofacial Surgery, Nanjing Stomatological Hospital, Medical School of Nanjing University, Nanjing, China.
Este artículo ha recibido

Under a Creative Commons license
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (11)
Mostrar másMostrar menos

This meta-analysis was conducted to evaluate the value of indocyanine green (ICG) in guiding sentinel lymph node biopsy (SLNB) for patients with oral cavity cancer.

An electronic database search (PubMed, MEDLINE, Cochrane Library, Embase, and Web of Science) was performed from their inception to June 2020 to retrieve clinical studies of ICG applied to SLNB for oral cavity cancer. Data were extracted from 14 relevant articles (226 patients), and 9 studies (134 patients) were finally included in the meta-analysis according to the inclusion and exclusion criteria.

The pooled sentinel lymph node (SLN) sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were 88.0% (95% confidence interval [CI], 74.0-96.0), 64.0% (95% CI, 61.0-66.0), 2.45 (95% CI, 1.31-4.60), 0.40 (95% CI, 0.17-0.90), and 7.30 (95% CI, 1.74-30.68), respectively. The area under the summary receiver operating characteristic curve was 0.8805.

In conclusion, ICG applied to SLNB can effectively predict the status of regional lymph nodes in oral cavity cancer.

KEYWORDS:
Oral Cavity Cancer
Indocyanine Green
Sentinel Lymph Node Biopsy
Sensitivity
Specificity
Texto completo
INTRODUCTION

Oral cavity cancer endangers human life and is the most common cancer worldwide. According to the National Comprehensive Cancer Network (NCCN) guidelines on oral cavity cancer treatment, cervical LN (lymph node) status is a critical determinant of therapeutic intervention. Selective neck dissection is performed for patients with undetectable LN or regional metastases, with a risk greater than 20% (1). However, cervical LN dissection affects the quality of life of the patients (2). Typical complications of this procedure include postoperative hematoma, wound dehiscence, chyle leak, skin flap necrosis, parotid gland fistula, and postoperative shoulder dysfunction (3). Therefore, accurate assessment of LN status in oral cavity cancer will help clinicians preserve patient function and reduce surgical complications as much as possible while thoroughly treating patients for their diseases.

Sentinel LN biopsy (SLNB) is an auxiliary diagnostic method for detecting and assessing neck metastasis and unpredictable lymphatic drainage in cN0 patients and has also been successfully applied in the detection of occult LN metastasis in head and neck cancer (HNC). Thompson et al. (4) concluded that the sensitivity of SLNB for the determination of regional LN metastasis was 94%. In addition, it was found that the negative predictive value (NPV) was 96% in 26 studies (766 patients with HNC). Civantos et al. (5) performed step sectioning and immunohistochemical tests on T1 or T2 patients (clinically N0) in oral squamous cell carcinomas, and the results showed that SLNB had a high accuracy with an NPV of 96%.

Indocyanine green (ICG) near-infrared (NIR) fluorescence imaging technology is also an SLNB technique that can detect sentinel lymph nodes (SLNs) favorably. This method has been clinically applied in the intraoperative imaging of lung cancer, breast cancer, and gastric cancer. However, the accuracy of ICG assessment and detection of SLN in oral cavity cancer is controversial because of the large number of LNs and the complicated drainage pathway, even with the possibility of skip metastases (6,7). Therefore, this systematic review and meta-analysis was performed to evaluate the diagnostic value of ICG for SLNs in oral cavity cancer.

MATERIALS AND METHODSSearch strategy

The protocol for the review was registered a priori in the International Prospective Register of Systematic Reviews under the registration number CRD42020134291.

An electronic database search (PubMed, MEDLINE, Cochrane Library, Embase, and Web of Science) was performed from the period of their inception to June 2020, which helped us retrieve clinical studies regarding the application of ICG in SLNB for HNC. The search strategy involved the use of the keywords “indocyanine green OR ICG” and “oral cancer OR gingiva cancer OR tongue cancer OR month floor cancer OR lip cancer OR buccal mucosa cancer OR palate cancer” and “lymph node OR LN OR lymphatic.” The medical subject headings (MeSH) used were as follows: indocyanine green, oral cavity neoplasms, and lymph nodes. Duplicate studies were first removed, and the studies were screened systematically based on the title and abstract, followed by a full-text screening. Taking the PubMed database search formula as an example, the search formula is as follows:

((“Oral Cavity Neoplasms”[Mesh]) OR ((((((oral cancer) OR (gingiva cancer)) OR (tongue cancer)) OR (month floor cancer)) OR (lip cancer)) OR (buccal mucosa cancer)) OR (palate cancer))) AND (((“Lymph Nodes”[Mesh]) OR (lymphatic)) OR (LN))) AND ((“Indocyanine Green”[Mesh]) OR (ICG)).

Inclusion and exclusion criteria

Metastatic LNs were detected via ICG NIR fluorescence in oral cavity cancer in the evaluation index, which contained data regarding true positive (TP), false positive (FP), false negative (FN), and true negative (TN) values. The inclusion and exclusion criteria used in the literature screening were as follows:

  • 1.

    Inclusion criteria: (i) LN resection for oral cavity cancer and pathological examination as the reference; (ii) ICG-guided SLN mapping; (iii) SLN determined the main research objective; and (iv) the reference standard and diagnostic methods had pathological data, pathologically examined routinely, which is typical of paraffin-embedded sections and immunohistochemical analysis after staining with hematoxylin and eosin (HE).

  • 2.

    Exclusion criteria: (i) repeated articles, reviews, conference reports, case reports, or letters; (ii) animal studies, ICG photothermal therapy-related studies; (iii) no cervical LN dissection; and (iv) lack of pathological examination or inability to obtain pathological data and the evaluation index (TP, FP, FN, and TN).

Data extraction

Two investigators independently screened the articles based on the inclusion and exclusion criteria and then assessed the study quality using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-2 evaluation criteria. Disagreements between the two investigators were resolved by referring to a third researcher. The investigators extracted the information contained in each study into an Excel spreadsheet, including the first author's last name, year of publication, study design, country, number of patients, age, type of disease, surgical procedure, total number of LNs collected, total number of fluorescent LNs, positive SLNs, average SLN number obtained in each patient, SLN detection method (ICG, radioisotope, and blue dye), method of pathological detection, commercial name of the ICG, concentration, dose, injection method, injection time, fluorescence imaging and detection time of the technique, follow-up results, and adverse reactions associated with ICG injection.

Calculation of the review parameters

According to the “PICO” principle, we identified P (population) as a patient with oral cavity cancer (cN0), I (intervention) as SLNB guided by ICG near-infrared fluorescence, C (control) as the reference test for diagnosis of postoperative pathological results, and O (outcome) as the diagnosis of metastatic lymph nodes. Therefore, we summarized the detection of SLNB in oral cavity cancer before or during the operation using ICG NIR fluorescence and compared it with the reference test (pathology) to evaluate the accuracy of ICG in detecting metastatic lymph nodes. For each study, TP, TN, PF, and FN rates were estimated accordingly. LNs detected via ICG NIR fluorescence were assessed by calculating the following values:

Statistical analysis

Statistical analyses were performed using Stata version 14.0 (Stata Corp. LLC, College Station, TX, USA) and Meta-Disc version 1.4 (Universitario Ramony Cajal Hospital, Madrid, Spain), which reported the ICG of NIR fluorescence-guided SLNB detection and routine pathological biopsy results of cervical LNs. Study quality was assessed using RevMan software (version 5.3; The Nordic Cochrane Centre, Copenhagen, Denmark). First, Meta-Disc was used to perform Spearman correlation analysis to assess the heterogeneity caused by the threshold effect. A p-value>0.05, indicated that there was no heterogeneity caused by the threshold effect while a p-value<0.05, indicated the existence of heterogeneity caused by threshold effects. Heterogeneity analysis was performed on sensitivity, specificity, PLR, NLR, and DOR using the Cochran Q test and I2 test. A p-value<0.05, indicated the existence of significant heterogeneity among the studies, and a random-effects model was used accordingly. A p-value>0.05 indicated the absence of significant heterogeneity among the studies, and the fixed-effects model was used for the analysis. A value of I2>50% represented high heterogeneity, 50%≥I2≥25% indicated moderate heterogeneity, and I2<25% indicated low heterogeneity. A meta-analysis was performed using a fixed-effects model or random-effects model for heterogeneity, pooling the combined detection rates, summaries of sensitivity, specificity, PLR, NLR, DOR, and summary receiver operating characteristic curve (SROC). Finally, a funnel plot was constructed using Stata to assess publication bias.

RESULTSCharacteristics of the studies

A total of 213 records were retrieved based on the search strategy. After removal of duplicates and manual screening for relevant titles and abstracts, the full text of 37 studies was assessed to check for inconsistencies and incomplete data of the research participants. Finally, 14 related studies were included in the systematic review. Of them, nine studies met the relevant criteria and were included in the meta-analysis (8-21) (Figure 1). The included studies subjected to quality evaluation using the QUADAS-2 are shown in Figure 2.

Figure 1.

Flowchart of study selection adapted from PRISMA.

(0.03MB).
Figure 2.

Methodological evaluation of the included studies according to the QUADAS-2 criteria (a) overall and (b) by study QUADAS, Quality Assessment of Diagnostic Accuracy Studies.

(0.07MB).
Patient characteristics and SLNB detection

Fourteen studies involving a total of 226 patients with a mean age of 61.5 (range, 48-65.5) years, were included in this review. The characteristics of these studies are presented in Table 1. ICG-guided fluorescence imaging was used for SLNB detection in each study, and the surgical procedures performed were selective LN dissection in all these studies. The LNs detected were assessed via routine pathological examination as the reference test, typically involving HE staining and immunohistochemistry. A total of 752 SLNs were detected by imaging, with a mean number of 3.33 in each patient, and the combined detection rate was 97%. In the present study, only one patient had lip cancer (13). One case of fluorescent LN was detected by SLNB, and no metastasis was confirmed by pathology.

Table 1.

Characteristics of the studies included.

Author  Year  Country  No.  Age (years)  Tumor  Reference test  Procedure  LNs  SLNs  SLN+  Mean SLNs  Follow-up 
Hoon Kim et al. (82020  South Korea  48  OSCC  pathology  RAND  313  31  3.4  No recurrence or metastasis were seen 
Ishiguro et al. (92020  Japan  27  65  tongue cancer  pathology  SND  ND  41  1.5  76 months, 3 of 22 patients without SLN metastasis had occult cervical lymph node metastasis, and 1 SLN positive case recurred 
Honda et al. (102019  Japan  16  65.5  tongue cancer  pathology  SND  ND  30  1.9  38 months, neck recurrence was found in 2 of the 11 patients who initially showed metastasis-negative SLNs 
Meershoek et al. (112019  Netherlands  19  59  tongue cancer  pathology  SND  69  60  3.2  − 
KleinJan et al. (122018  Netherlands  51  61  OSCC  pathology  SND  357  293  10  5.7  33 months, false negative findings of oral cavity patients occurred in the first 15 cases 
Digonnet et al. (132016  Belgium  56.5  oral cancer  pathology  SND  23  −  3-22 months (0 recurrence) 
Christensen et al. (142016  Denmark  30  64  OSCC  pathology  SND  ND  94  3.1  − 
Peng et al. (152015  China  19  60.5  OSCC  pathology  SND (18)RND (1)  420  61  3.2  − 
Nakamura et al. (162015  Japan  −  tongue cancer  pathology  SND  ND  2.7  No recurrence or metastasis were seen 
Murase et al. (172015  Japan  16  65.5  oral cancer  pathology  SND  ND  35  2.2  more than 3 years, (1 ICG imaging patient died of lung metastasis; no other signs of recurrence or metastasis were seen) 
Borbón-Arce et al. (182014  Spain  60  OSCC  pathology  SND  30  30  3.3  − 
Joost et al. (192013  Germany  59.5  oral cancer  pathology  SND  184  15  1.9  − 
Frontado et al. (202013  Spain  52  OSCC  pathology  SND  − 
Nynke et al. (212012  Netherlands  14  60.5  OSCC  pathology  SND  94  47  3.4  − 

Abbreviations: ND, not detected; OSCC, oral squamous cell cancer; RAND, robotic retroauricular neck dissection; SND, selective neck dissection; SLN, sentinel lymph node SLN+, positive SLN.

Technical aspects of ICG NIR fluorescence

Different commercial labels of ICG and different concentrations (0.25, 1.25 mg/ml, 2.5, and 5 mg/ml) and doses (0.2-2 ml) of the same were used among the included studies. The ICG injection site was peritumoral injection. The time of injection could be preoperative, intraoperative, preoperative, or intraoperative respectively. In addition, other detection methods (99mTc, human serum albumin, and blue dye) were used, with the application of corresponding equipment including the Firefly system, robotic system, computed tomographic lymphography (CTL), photodynamic eye (PDE), fluid-attenuated inversion recovery near-infrared camera (FLAIR), γ-probe, SPECT/CT imaging, a HyperEye Medical System (HEMS) monitor, and a Mini-Fluorescence-Assisted Resection and Exploration imaging system. There were differences in NIR fluorescence detection and imaging time (within 1-2 min, 10 min, 15 min, 20 min, 30 min, and 2 h or more). The specific details are listed in Table 2.

Table 2.

Technical aspects of ICG near-infrared fluorescence.

Author  Commercial name of ICG  Concentration  Dose  Detection method  Injection site  Equipment  Injection time  Fluorescent time 
Hoon Kim et al. (8  2.5 mg/ml  2 ml  ICG  peritumoral  Firefly system, robotic system,  preoperative  − 
Ishiguro et al. (9Daiichi Sankyo Company, Tokyo, Japan  5 mg/ml  2 ml  ICG  peritumoral  CTL, near-infrared camera  intraoperative  − 
Honda et al. (10Daiichi Pharmaceutical  5 mg/ml  2 ml  CT lymphography, ICG  peritumoral  FLAIR, near-infrared camera, HEMS, PDE  preoperative  1 min/2 min 
Meershoek et al. (11ICG-Pulsion; Pulsion Medical Systems  1.25 mg/ml  80 MBq  ICG-99mTc-nanocolloid  peritumoral  PDE, near-infrared camera,  preoperative  − 
KleinJan et al. (12Pulsion Medical Systems, Múnich, Germany  1.25 mg/ml  81 MBq  ICG-99mTc-nanocolloid, blue dye  peritumoral  SPECT/CT, near-infrared camera, γ-probe  preoperative  15 min/2 h 
Digonnet et al. (13Pulsion Medical System, Belgium  0.25 mg/kg  −  ICG  intravenous  near-infrared camera  intraoperative  2 h 
Christensen et al. (14ICG-Pulsion,Pulsion Medical, Germany  0.25 mg/ml  0.2 ml  ICG-99mTc -nanocolloid  peritumoral  SPECT/CT, near-infrared camera, γ-probe  preoperative  − 
Peng et al. (15Dandong, China  5 mg/ml  1 ml  blue dye, ICG  peritumoral  near-infrared camera  preoperative  10 min 
Nakamura et al. (16Daiichi Sankyo, Tokyo, Japan  2.5 mg/ml  0.5 ml  99mTc, ICG  peritumoral  HEMS monitor,  preoperative  19.8±12.6 min 
Murase et al. (17Diagnogreen; Daiichi Pharmaceutical, Tokyo, Japan  5 mg/ml  0.4 ml  ICG  peritumoral  γ-probe  intraoperative  2 h 
Borbón-Arce et al. (18ICG-Pulsion, Pulsion Medical Systems, Múnich, Germany  2.5 mg/ml  85 MBq  ICG-99m Tc-nanocolloid  peritumoral  SPECT/CT, near-infrared camera, γ-probe, PDE  preoperative  15 min/2 h 
Joost et al. (19Pulsion Medical Systems (Múnich, Germany)  2.5 mg/ml  1.6 mL  blue dye, ICG-99m Tc, HSA  peritumoral  Mini-FLARE imaging system  preoperative  5/10/15/30 min 
Frontado et al. (20ICG-Pulsion, Pulsion Medical Systems, Múnich, Alemania  5 mg/ml  86.5 MBq  ICG-99m Tc-nanocolloid  peritumoral  SPECT/CT, γ- camera  preoperative  10 min/15 min/2 h 
Nynke et al. (21Pulsion Medical Systems, Múnich, Germany  2.5 mg/ml  0.4 ml  ICG-99m Tc -nanocolloid  peritumoral  SPECT/CT, near-infrared camera, γ-probe,  preoperative  3-19 h 

Abbreviations: HEMS, HyperEye Medical System; CT, computed tomography; CTL, computed tomographic lymphography; FLAIR, fluid-attenuated inversion recovery; ICG, indocyanine green; PDE, Photo Dynamic Eye; SPECT, single-photon emission computed tomography.

Fluorescent and pathologic result of LNs

The harvested LNs were examined via routine pathology and the results showed that 55 metastatic fluorescent positive LNs (TP) and 3 fluorescent negative but metastasized LNs (FN) were reported form all the studies. Additionally, 697 cases of nonmetastatic LNs were present in the LNs that showed positive fluorescence (FP).

Overall sensitivity, specificity, and accuracy of ICG NIR fluorescence

Nine studies were included in the meta-analysis. For the individual and combined incidence rates of FP, FN, TP, and TN, the four grid tables are listed in Table 3. First, the included studies were subjected to threshold effect analysis in Meta-Disc, and the sensitivity logarithm related to the (1-specificity) logarithm of the Spearman coefficient was equal to 0.381 (p=0.311, indicating no significance); simultaneously there was no “shoulder arm” distribution in the comprehensive SROC. Both results suggest that there was no threshold effect in this study (Figure 3). All studies were heterogeneously analyzed in Stata 14.0, and the Galbraith plot showed that all points fell within the 95% confidence interval (CI) range. Second, as the analysis in Meta-Disc showed (Figure 5a-e), the median sensitivity for ICG fluorescence in the detection of malignant LNs was 91.0% (95% CI, 67.0-95.0), the median specificity was 51% (95% CI, 2.0-98.0), the median PLR was 1.35 (95% CI, 0.73-30.0), and the median NLR was 0.37 (95% CI, 0.10-3.77). The heterogeneity test for sensitivity as the effect amount yielded I2=0.0% (p=0.92), indicating little heterogeneity among the studies, and the fixed sensitivity model was set to obtain a pooled sensitivity of 88.0% (95% CI, 74.0-96.0) (Figure 4a). The heterogeneity test for specificity yielded I2=98.9% (p<0.0001), indicating a large degree of heterogeneity; therefore, a random-effect model analysis was set to obtain a pooled specificity of 64.0% (95% CI, 61.0-66.0) (Figure 4b). Similarly, the pooled PLR and NLR were 2.45 (95% CI, 1.31-4.60) and 0.40 (95% CI, 0.17-0.9), respectively (Figure 4c and d). Regarding the DOR (I2=42.5%, p=0.084), a fixed-effect model was used to obtain a comprehensive value of 7.30 (95% CI, 1.74-30.68) (Figure 4e). Finally, the area under the combined subject working SROC was 0.88 (Q value=0.81), and the standard error was 0.047 (Figure 3).

Table 3.

The TP, FP, FN, and TN results of the included articles.

Author  TP  FP  FN  TN 
Hoon Kim et al. (826  282 
Meershoek et al. (1155 
KleinJan et al. (1210  283  64 
Digonnet et al. (1322 
Peng et al. (1556  359 
Borbón-Arce et al. (1824 
Joost et al. (1913  118 
Frontado et al. (20
Nynke et al. (2146  47 
Total  36  508  901 

Abbreviations: FN, false positive, FN, false negative; TP, true positive, TN, true negative.

Figure 3.

Threshold effect in covariate analysis of sensitivity and specificity of ICG NIR fluorescence imaging among the studies. AUC, area under the curve; ICG, indocyanine green; NIR, near-infrared; SE, standard error; SROC, summary receiver operating characteristic curve.

(0.04MB).
Figure 5.

Subgroup analysis of ICG combined with other detection methods. (a) The sensitivity and specificity of only free ICG NIR fluorescence imaging; (b) the sensitivity and specificity of the ICG-99mTc- nanocolloid; (c) the sensitivity and specificity of ICG combined with blue dye and the ICG-99mTc- nanocolloid. CI, confidence interval; ICG, indocyanine green; NIR, near-infrared.

(0.05MB).
Figure 4.

Forest plots of ICG NIR fluorescence imaging in oral cavity cancer (a) sensitivity, (b) specificity, (c) PLR, (d) NLR, and (e) DOR. DOR, Diagnostic odds ratio; ICG, indocyanine green; NIR, near-infrared; NLR, negative likelihood ratio; PLR, Positive likelihood ratio.

(0.07MB).
Comparison of free ICG and other tracers

As shown in the above results, the pooled sensitivity and specificity of free ICG (n=11) were 86.0% (95% CI, 42.0-100.0) and 92% (95% CI, 89.0-95.0) in three studies (Figure 5a) (8,13). Assessment of ICG-99mTc- nanocolloid (n=45) (11,18,20,21) or the combination of ICG-99mTc- nanocolloid and blue dye (n=59) (12,19) showed that they had a higher sensitivity (Figure 5b, c). It was also concluded from Figure 4 that ICG combined with methylene blue had higher sensitivity (91%) and specificity (87%) (15).

Assessment of publication bias

A funnel plot constructed in Stata 14.0 to evaluate publication bias yielded a p-value of 0.90, indicating no significant publication bias.

GRADE evidence classification

The GRADE profiler software ranked the evidence quality of the included studies (Table 4). It is thus shown that more than moderate-quality evidence indicates the accuracy of this research.

Table 4.

Sensitivity and specificity GRADE classification results of SLNB in HNC using indocyanine green.

        Factors that may decrease certainty of evidence 
Study  Outcome  No. of patients  Study design  Risk of bias  Indirectness  Inconsistency  Imprecision  publication bias  Test accuracy CoE 
Hoon Kim et al. (8)sensitivity  cross-sectional  not serious  not serious  not serious  not serious  not serious  ⊕⊕⊕○/B 
specificity    (−1)a  not serious  not serious  not serious  not serious  not serious  ⊕⊕⊕○/B 
Meershoek et al. (11)sensitivity  19  cross-sectional  not serious  not serious  not serious  not serious  not serious  ⊕⊕⊕○/B 
specificity    (−1)a  not serious  not serious  (−1)b  not serious  not serious  ⊕⊕○○/C 
KleinJan et al. (12)sensitivity  51cross-sectional  not serious  not serious  (+1)  not serious  not serious  ⊕⊕⊕⊕/A 
specificity  (−1)a  not serious  not serious  not serious  not serious  not serious  ⊕⊕⊕○/B 
Digonnet et al. (13)Sensitivity  2cross-sectional  not serious  not serious  not serious  (−1)c  not serious  ⊕⊕○○/C 
specificity  (−1)a  not serious  not serious  not serious  (−1)c  not serious  ⊕⊕○○/C 
Peng et al. (15)Sensitivity  19cross-sectional  not serious  not serious  not serious  not serious  not serious  ⊕⊕⊕○/B 
specificity  (−1)a  not serious  not serious  not serious  not serious  not serious  ⊕⊕⊕○/B 
Borbón-Arce et al. (18)Sensitivity  9cross-sectional  not serious  not serious  not serious  not serious  not serious  ⊕⊕⊕○/B 
specificity  (−1)a  not serious  not serious  (−1)b  not serious  not serious  ⊕⊕○○/C 
Joost et al. (19)Sensitivity  8cross-sectional  not serious  not serious  not serious  not serious  not serious  ⊕⊕⊕○/B 
specificity  (−1)a  not serious  not serious  not serious  not serious  not serious  ⊕⊕⊕○/B 
Frontado et al. (20)Sensitivity  3cross-sectional  not serious  not serious  not serious  (−1)c  not serious  ⊕⊕○○/C 
specificity  (−1)a  not serious  not serious  not serious  (−1)c  not serious  ⊕⊕○○/C 
Nynke et al. (21)Sensitivity  14cross-sectional  not serious  not serious  not serious  not serious  not serious  ⊕⊕⊕○/B 
specificity  (−1)a  not serious  not serious  not serious  not serious  not serious  ⊕⊕⊕○/B 

Abbreviations: HNC, head and neck cancer; SLNB, sentinel lymph node biopsy. a cross-sectional study is not a randomized controlled study, and the level of evidence needs to be downgraded; b. the sample has low homogeneity, considered to degrade; c) the size of homogeneous sample affects the reliability of the results.

DISCUSSION

Occult metastatic LNs are negative on clinical examination but positive when assessed by pathology. Some scholars have assigned them clinically to LN negative (cN0) status. A previous study showed that occult LNs were more common in patients with oral cavity cancer and were present in 20%-30% of cases (22). The prognosis of patients with cN0 disease with identifiable and dissectible occult metastatic LNs is better than that of patients managed via observation and LN resweeping. However, this approach will also lead to 65%-70% of the cases receiving overtreatment with a wide range of radical neck surgeries in patients with cN0 disease (23). Compared with tracers such as radionuclides, ICG is nonradioactive and has a higher biosafety. Additional clinical studies have assessed the application of ICG in SLNB for oral cavity cancer; however, oral cavity cancer has a high rate of LN metastasis and complicated drainage pathways, and the results are not the same according to different reports (24). Therefore, to obtain more objective evidence-based medical support, we conducted a meta-analysis of the diagnostic value of SLNB for oral cavity cancer with ICG as a tracer for metastatic LNs.

During the systematic review, five studies that aimed to detect fluorescent LNs, were evaluated to determine whether neck dissection was performed (9,10,17), and to compare the fluorescence imaging time and fluorescent SLN number according to different SLNB methods (14,16). On account of the lack of comparison with histopathological examination of LNs in neck dissection specimens, these studies were excluded from our final meta-analysis. In this study, for ICG as the main tracer in SLNB, the pooled sensitivity for the detection of metastatic LNs was 88.0% (95% CI, 74.0-96.0), and the median sensitivity was 91.0% (95% CI, 67.0-95.0). The pooled specificity was low at 64.0% (95% CI, 61.0-66.0). Although the highest specificity was 98.0% (95% CI, 81.0-100.0), the median specificity was 51% (95% CI, 2.0-98.0). The reason for the low specificity was that there were six studies with a lower number of fluorescence (-) and metastasis (-) LNs than fluorescent (+) and metastatic (-) SLNs, resulting in a lower TN/TN+FP value. Specifically, the above results may be due to the following reasons: (i) The choice of the surgical procedure, as the selected studies mostly used selective SLN dissection, resulting in postoperative detection of mostly fluorescent (+) SLNs and fewer fluorescence (-) and metastasis (-) LNs (TN). (ii) The choice of clinical cases; the number of patients included in the study was small or the number of LNs with occult metastasis was relatively small, resulting in more fluorescence (+) and metastasis (-) LNs (FP). (iii) The special lymphatic drainage system of the head and neck, making SLNB for oral cavity cancer more complicated than for other cancers (25).

Similar to dyes and radionuclides, ICG injected into the normal tissues surrounding the cancer lesions drains to the LNs along with the lymph. SLNs can then be identified and located via lymphatic scintigraphy. Ramamurthy et al. (26) applied methylene blue dye alone to locate the SLN of oral cancer and reported a recognition rate of 90.6% (n=29/32) and an FN rate of 20%. In this meta-analysis, we included ICG in combination with blue dye or nuclides in the SLNB of oral cavity cancer and performed sensitivity and specificity analyses accordingly. The results showed that the hybrid ICG-99mTc-nanocolloid could increase the sensitivity of metastatic LN detection to 87% (95% CI, 60-96), and there were no FN cases in the limited sample size (11,18,20,21). Similarly, ICG in combination with methylene blue exhibited higher sensitivity than ICG alone (15). However, both specificities were lower, which may be related to the reasons described previously. In addition to the different tracers, different imaging devices also affected the SLN detection results. Taken together, this approach is feasible for SLNB using tracer technology in oral cavity cancer; however, the research evidence needs to be further strengthened.

Other factors may also affect the detection of SLNs in oral cavity cancers. The concentrations of ICG were different (5 mg/ml, 2.5 mg/ml, 1.25 mg/ml, and 0.25 mg/ml), and the detection effect was also different. Using 5 mg/ml ICG (n=22), the sensitivity and specificity of SLN detection were 86% (95% CI, 42-100) and 85% (95% CI, 82-89), respectively; using 2.5 mg/ml ICG (n=40), the sensitivity and specificity were 85% (95% CI, 59-97) and 80% (95% CI, 77-84), respectively; and using 1.25 mg/ml (n=70) yielded a sensitivity and specificity of 94% (95% CI, 70-100) and 18% (95% CI, 14-22), respectively. From the above results, it is seen that the sensitivity of SLN detection also increased with increasing ICG concentration. However, in the study where ICG was applied for the detection of SLNB in gastric cancer, Meifeng et al. (27) found that the sensitivity of the concentration of 5 mg/ml was lower than that of 0.5 or 0.05 mg/ml (0.83 versus 0.98), which was related to the study design as mentioned earlier. Therefore, the relationship between ICG concentration and SLN detection sensitivity requires a large sample study to be conducted.

Few studies have examined the postoperative recurrence of SLNB in patients with cancer. Seven studies with existing follow-up records were included in our study, and four of them had no local recurrence or regional LN metastasis occurrence, but one ICG imaging patient died of lung metastasis (17). The remaining three studies reported that at least one patient experienced local tumor recurrence (9,10,12). FN results of SLNB in HNC may miss metastatic LNs, leading to postoperative recurrence. Knackstedt et al. (28) and Ahmed et al. (29) performed ICG-guided SLNB in patients with HNC, with FN rates of 1.64% (1/61) and 20% (4/20), respectively. In this meta-analysis, 226 patients were included, with an FN rate of 0.88% (2/226). The causes of FN were as follows: (i) no micrometastases in SLNs found on pathological examination; (ii) the metastatic tumor cells blocked the draining lymphatic vessels of the primary tumor, causing changes in the drainage pathway and there was a failure to identify true SLNs; and (iii) a metastatic shift in the LNs had occurred (30). Lymphatic drainage is complicated, and SLNs are difficult to locate in the head and neck; therefore, the results regarding the effectiveness of SLNB as applied to oral cavity cancer are inconsistent.

This meta-analysis suggests that ICG-guided SLNB can effectively detect SLN to determine further metastatic LN in patients with oral cavity cancer, especially those with T1 and T2. In the GRADE evidence rating, there is more than moderate-quality evidence that ICG applied to SLNB for the diagnosis of metastatic lymph nodes in oral cavity cancer has high sensitivity; however, the specificity is still greatly affected by the sample size. In the future, it is necessary to expand the sample size and analyze more high-quality studies to evaluate its clinical value.

CONCLUSIONS

ICG applied to SLNB for detecting regional metastatic LNs was demonstrated to be feasible for oral cavity cancer. Based on the evidence from this study with a limited sample size, ICG combined with dyes or radionuclide-guided SLN mapping increased the sensitivity and specificity and reduced the occurrence of FN results. Only nine studies that were heterogeneous were included in this study. Therefore, further well-designed studies with larger sample sizes are needed to yield more reliable follow-up results.

AUTHOR CONTRIBUTIONS

Chen Y, Wang Y and Zhang K were responsible for the study design. Xiao Q, Zou W, Xia C and Yin H were responsible for the data acquisition and analysis. Xiao Q, Xia C, Yin H and Pu Y were responsible for the results interpretation, manuscript writing and revision.

ACKNOWLEDGMENTS

The authors gratefully acknowledge the support for this research from the Key Project of Natural Science Research for College and University of Anhui Province (KJ2019A0356), the Jiangsu Province Science & Technology Department (BE2018618), Nanjing Department of Health (YKK18120), and Nanjing Medical Science and Technical Development Foundation (QRX17174).

REFERENCES
[1]
M Contaldo , A Di Napoli , G Pannone , R Franco , F Ionna , A Feola , et al.
Prognostic implications of node metastatic features in OSCC: a retrospective study on 121 neck dissections.
[2]
CR Leemans , R Tiwari , JJ Nauta , I van der Waal , GB Snow .
Regional lymph node involvement and its significance in the development of distant metastases in head and neck carcinoma.
[3]
R Pellini , G Mercante , C Marchese , V Terenzi , I Sperduti , V Manciocco , et al.
Predictive factors for postoperative wound complications after neck dissection.
Acta Otorhinolaryngol Ital, 33 (2013), pp. 16-22
[4]
CF Thompson , MA St John , G Lawson , T Grogan , D Elashoff , AH Mendelsohn .
Diagnostic value of sentinel lymph node biopsy in head and neck cancer: a meta-analysis.
[5]
FJ Civantos , RP Zitsch , DE Schuller , A Agrawal , RB Smith , R Nason , et al.
Sentinel lymph node biopsy accurately stages the regional lymph nodes for T1-T2 oral squamous cell carcinomas: results of a prospective multi-institutional trial.
[6]
FL Dias , RA Lima , J Kligerman , TP Farias , JR Soares , G Manfro , et al.
Relevance of skip metastases for squamous cell carcinoma of the oral tongue and the floor of the mouth.
[7]
GB Flach , E Bloemena , WM Klop , RJ van Es , KP Schepman , OS Hoekstra , et al.
Sentinel lymph node biopsy in clinically N0 T1-T2 staged oral cancer: the Dutch multicenter trial.
[8]
JH Kim , HK Byeon , DH Kim , SH Kim , EC Choi , YW Koh .
ICG-Guided Sentinel Lymph Node Sampling during Robotic Retroauricular Neck Dissection in cN0 Oral Cancer.
[9]
K Ishiguro , T Iwai , T Izumi , S Sugiyama , J Baba , S Oguri , et al.
Sentinel lymph node biopsy with preoperative CT lymphography and intraoperative indocyanine green fluorescence imaging for N0 early tongue cancer: A long-term follow-up study.
[10]
K Honda , K Ishiyama , S Suzuki , Y Kawasaki , H Saito , A Horii .
Sentinel Lymph Node Biopsy Using Preoperative Computed Tomographic Lymphography and Intraoperative Indocyanine Green Fluorescence Imaging in Patients With Localized Tongue Cancer.
[11]
P Meershoek , NS van den Berg , OR Brouwer , HJ Teertstra , CAH Lange , RA Valdés-Olmos , et al.
Three-Dimensional Tumor Margin Demarcation Using the Hybrid Tracer Indocyanine Green-99mTc-Nanocolloid: A Proof-of-Concept Study in Tongue Cancer Patients Scheduled for Sentinel Node Biopsy.
[12]
GH KleinJan , E van Werkhoven , NS van den Berg , MB Karakullukcu , HJMAA Zijlmans , JA van der Hage , et al.
The best of both worlds: a hybrid approach for optimal pre- and intraoperative identification of sentinel lymph nodes.
[13]
A Digonnet , S van Kerckhove , M Moreau , E Willemse , M Quiriny , B Ahmed , et al.
Near infrared fluorescent imaging after intravenous injection of indocyanine green during neck dissection in patients with head and neck cancer: A feasibility study.
[14]
A Christensen , K Juhl , B Charabi , J Mortensen , K Kiss , A Kjær , et al.
Feasibility of Real-Time Near-Infrared Fluorescence Tracer Imaging in Sentinel Node Biopsy for Oral Cavity Cancer Patients.
[15]
H Peng , SJ Wang , X Niu , X Yang , C Chi , G Zhang .
Sentinel node biopsy using indocyanine green in oral/oropharyngeal cancer.
[16]
T Nakamura , Y Kogashiwa , H Nagafuji , K Yamauchi , N Kohno .
Validity of sentinel lymph node biopsy by ICG fluorescence for early head and neck cancer.
Anticancer Res, 35 (2015), pp. 1669-1674
[17]
R Murase , H Tanaka , T Hamakawa , H Goda , T Tano , A Ishikawa , et al.
Double sentinel lymph node mapping with indocyanine green and 99m-technetium-tin colloid in oral squamous cell carcinoma.
[18]
M Borbón-Arce , OR Brouwer , NS van den Berg , H Mathéron , WM Klop , AJ Balm , et al.
An innovative multimodality approach for sentinel node mapping and biopsy in head and neck malignancies.
[19]
JR van der Vorst , BE Schaafsma , FP Verbeek , S Keereweer , JC Jansen , LA van der Velden , et al.
Near-infrared fluorescence sentinel lymph node mapping of the oral cavity in head and neck cancer patients.
[20]
ML Frontado , OR Brouwer , NS van den Berg , HM Mathéron , S Vidal-Sicart , FW van Leeuwen , et al.
Added value of the hybrid tracer indocyanine green-99mTc-nanocolloid for sentinel node biopsy in a series of patients with different lymphatic drainage patterns.
[21]
NS van den Berg , M Miwa , GH KleinJan , T Sato , Y Maeda , AC van Akkooi , et al.
(Near-Infrared) Fluorescence-Guided Surgery Under Ambient Light Conditions: A Next Step to Embedment of the Technology in Clinical Routine.
[22]
SH Huang , B O’Sullivan .
Overview of the 8th Edition TNM Classification for Head and Neck Cancer.
[23]
M Russolo , V Giacomarra , L Papanikolla , G Tirelli .
Prognostic indicators of occult metastases in oral cancer.
[24]
SJ Stoeckli , M Pfaltz , GL Ross , HC Steinert , DG MacDonald , C Wittekind , et al.
The second international conference on sentinel node biopsy in mucosal head and neck cancer.
[25]
Y Yaguchi , H Tsujimoto , S Hiraki , N Ito , S Nomura , H Horiguchi , et al.
Long-term outcome following sentinel node navigation surgery for cT1 gastric cancer.
[26]
R Ramamurthy , R Kottayasamy Seenivasagam , S Shanmugam , K Palanivelu .
A prospective study on sentinel lymph node biopsy in early oral cancers using methylene blue dye alone.
[27]
M He , Z Jiang , C Wang , Z Hao , J An , J Shen .
Diagnostic value of near-infrared or fluorescent indocyanine green guided sentinel lymph node mapping in gastric cancer: A systematic review and meta-analysis.
[28]
RW Knackstedt , RA Couto , B Gastman .
Indocyanine green fluorescence imaging with lymphoscintigraphy for sentinel node biopsy in head and neck melanoma.
[29]
A Al-Dam , C Precht , A Barbe , C Kohlmeier , H Hanken , J Wikner , et al.
Sensitivity and specificity of sentinel lymph node biopsy in patients with oral squamous cell carcinomas using indocyanine green fluorescence imaging.
[30]
K Kataria , A Srivastava , D Qaiser .
What Is a False Negative Sentinel Node Biopsy: Definition, Reasons and Ways to Minimize It?.

No potential conflict of interest was reported.

Contributed equally to this work.

Copyright © 2021. CLINICS
Descargar PDF
Opciones de artículo
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos