ORIGINAL
Confiabilidad de la batería de evaluación propioceptiva en personas con amputación transtibial que utilizan prótesis, en el Hospital Militar Central
Reliability of the proprioceptive assessment battery in people with artificial limbs after transtibial amputation at the Central Military Hospital
Visitas
46
N.S. Landínez-Parraa,
Autor para correspondencia
nslandinezp@unal.edu.co

Autor para correspondencia.
, G.E. Villamizar-Garzónb, G.G. Aldana-Calderóna, D.A. Araujo-Moncayoa
a Facultad de Medicina Universidad Nacional de Colombia, Bogotá, Colombia
b Hospital Militar Central, Bogotá, Colombia
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (4)
Mostrar másMostrar menos
Tablas (2)
Tabla 1. Caracterización de la población incluida en el estudio
Tabla 2. Índices kappa por pruebas específicas
Mostrar másMostrar menos
Resumen
Antecedentes

Durante décadas, se han utilizado diferentes escalas, test y baterías para medir las cualidades físicas de las personas, como la propiocepción. Aunque existen pruebas que evalúan la propiocepción y se aplican en la práctica clínica, no existen pruebas válidas y confiables para poblaciones en condiciones especiales, como la amputación.

Objetivo

Determinar la confiabilidad de la batería de evaluación propioceptiva en amputados transtibiales (BEPAT), en pacientes del Hospital Militar Central de Bogotá, Colombia.

Materiales y métodos

Se realizó un estudio de tipo transversal utilizando la BEPAT para evaluar pacientes que se encontraban en el proceso de rehabilitación en el Servicio de Prótesis y Amputados del Hospital Militar Central en Bogotá. Se reclutó a 30 pacientes utilizando un enfoque de tipo a conveniencia no probabilístico. Los criterios de inclusión consideraron: ser mayor de edad, con amputación transtibial unilateral de etiología traumática, usar una prótesis, poder adoptar postura bípeda y unipodal y realizar marcha. La prueba fue aplicada por 2 evaluadores con un enfoque test-retest.

Resultados

Mediante el coeficiente RV de Y. Escoufier como una medida de similitud, se encontró una confiabilidad interevaluador de 0,99 y una intraevaluador 0,78.

Conclusiones

La BEPAT tiene una confiabilidad interevaluador muy alta y una confiabilidad intraevaluador alta. En general, la muy alta relación entre las observaciones realizadas por los 2 evaluadores en cada una de las 2 pruebas realizadas, permite recomendar la batería como un instrumento confiable para la evaluación de la propiocepción en hombres jóvenes amputados a nivel transtibial.

Palabras clave:
Propriocepción
Confiabilidad
Amputación
Abstract
Background

For decades, different scales, tests, and batteries have been used to measure physical abilities such as proprioception. Although there are tests in the clinical practice for assessing proprioception, there are no valid and reliable tests for populations with special conditions, such as amputation.

Objective

To determine the reliability of the Proprioceptive Assessment Battery on Patients with Transtibial Amputations (BEPAT in Spanish) in patients of the Hospital Militar Central of Bogotá, Colombia.

Materials and methods

A cross-sectional study was conducted using the BEPAT to assess patients undergoing rehabilitation for traumatic transtibial amputation in the Hospital Militar Central of Bogotá. A total of 30 patients were recruited using a non-probabilistic convenience approach. Inclusion criteria included: being of legal age, having unilateral transtibial amputation of traumatic origin, using a prosthesis, being able to adopt unipedal and bipedal standing, and perform a gait test. The test was applied by two evaluators with a test-retest approach.

Results

An inter-rater reliability of 0.99 and an intra-rater reliability of 0.78 were found when using the Escoufier RV coefficient as a similarity measure.

Conclusions

The BEPAT has a very high inter-rater and intra-rater reliability. A very high statistical relationship was found between the observations made by the two evaluators in each of the two tests. This allows the BEPAT to be recommended as a reliable tool for assessing proprioception in young men with transtibial amputations.

Keywords:
Proprioception
Reliability
Amputation

Artículo

Opciones para acceder a los textos completos de la publicación Fisioterapia
Socio
Socios AEF

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Problemas con el acceso de socios AEF
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
E-mail
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Fisioterapia

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos

Quizás le interese:
10.1016/j.ft.2020.02.001
No mostrar más