covid
Buscar en
Journal of Applied Research and Technology. JART
Toda la web
Inicio Journal of Applied Research and Technology. JART Efficient conversion from infrared to red light by cascaded nonlinear optical pr...
Información de la revista
Vol. 13. Núm. 6.
Lasers in Optics
Páginas 582-585 (diciembre 2015)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Visitas
1822
Vol. 13. Núm. 6.
Lasers in Optics
Páginas 582-585 (diciembre 2015)
Original
Open Access
Efficient conversion from infrared to red light by cascaded nonlinear optical processes using an aperiodically poled lithium niobate crystal
Visitas
1822
Juan Eduardo Gonzáleza, Luis Antonio Ríosa, Diego Rubén Yankelevichb, Roger Sean Cudneya,
Autor para correspondencia
rcudney@cicese.mx

Corresponding author.
a Departamento de Óptica, Centro de Investigación Científica y de Educación Superior de Ensenada, Carretera Ensenada-Tijuana No. 3918, Zona Playitas, Ensenada, B.C. CP 22860, Mexico
b Department of Electrical and Computer Engineering, University of California, 3101 Kemper Hall, Davis, CA 95616, USA
Este artículo ha recibido

Under a Creative Commons license
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (4)
Mostrar másMostrar menos
Abstract

We present a scheme for conversion of pulsed light from the infrared to the red spectral region, using an aperiodically poled ferroelectric crystal within a resonant cavity in which two cascaded nonlinear optical processes occur when pumped with a pulsed Nd:YAG laser. This device emits 9ns pulses of over 1mJ at 710nm and is a viable source for future biomedical applications.

Keywords:
Lithium niobate
Nonlinear wave mixing
Nonlinear optics
Devices
Parametric oscillators and amplifiers
Texto completo

Lasers have a wide range of applications in medicine, both in surgery and diagnostics, mainly since they can be made to interact with selected target area regions with minimal collateral damage to nearby regions. Some of these biomedical applications require the use of light in the red and near infrared region of the spectrum; for example the ruby laser has been used successfully in treatment of melanoma (Polla et al., 1987), destruction of hair follicles (Grossman, Dierickx, Farinelli, Flotte, & Anderson, 1996) and tattoo removal (Goldman, Wilson, Hornby, & Meyer, 1965) among other applications. The HeNe laser has also been used successfully for capillary blood flow measurement using the technique of laser-Doppler spectroscopy (De Mul et al., 1984) and also in dermatology for the treatment of skin spots or to stimulate tissue regeneration in scars.

Photoacoustic imaging, also called optoacoustic imaging, is a diagnostic technique which is based on the detection of acoustic waves induced in tissue by the absorption of electromagnetic radiation, usually from pulsed sources on a nanosecond timescale. The optical wavelengths most commonly used are between 600 and 900nm because they can penetrate up to several centimeters of human tissue (Emelianov et al., 2006). This technique can be used to detect hemoglobin, lipids, water, microcalcifications in breast tissue, among other things. In the particular case of microcalcifications, a wavelength between 600 and 800nm is optimal to obtain photoacoustic images (Kang et al., 2011); however the optical pulse sources currently used for this technique are expensive and bulky, which restricts the further application of this technology in medicine and biology.

As an alternative to the current light sources, in recent works the use of optical parametric oscillators (OPO) based on aperiodically poled ferroelectric crystals has been proposed. In these devices light in the red spectral region can be obtained through nonlinear optical processes, for example in (Figen & Akın, 2014) a device was presented that emits at 632nm using a Nd:YAG laser as the pump source, with the OPO being injection-seeded with a 1550nm laser diode.

Here we present a simple device that emits nanosecond pulses at a wavelength of 710nm (deep red) specifically for photoacoustic imaging which is also based on an aperiodically poled ferroelectric crystal. In this case however, it requires only a Nd:YAG laser source to obtain the red beam.

We convert light from 1064nm to 710nm with quasi-phase-matching obtained with an aperiodically poled lithium niobate crystal, as described in (Robles-Agudo & Cudney, 2011). In order to achieve this conversion it is necessary to perform at least two cascaded nonlinear optical processes within the crystal. We designed a crystal which produces optical parametric generation at the degeneracy point, i.e. the signal and idler wavelengths are the same, 2128nm, which is twice the wavelength of the pump beam, and simultaneously a sum-frequency generation process between the pump and signal waves resulting in a beam with a wavelength equal to 2/3 of the pump wavelength, 710nm.

From Maxwell's equations we can deduce the coupling among the waves. Let Ap, As and Ar be the electric field amplitudes of the pump, signal and red waves, with angular frequencies of ωp, ωs and ωr, and kp, ks and kr their corresponding wavevectors. Assuming that the three waves are co-propagating along the same direction, from Maxwell's equations we deduce that the coupled wave equations for these amplitudes are

Here z is the distance along the propagation direction of the waves, np,ns and nr are the refractive indices of the pump, signal and red waves, χ(2)(z) is the spatially-varying nonlinearity of the medium, c is the speed of light and ΔkOPO and ΔkSFG are the propagation constant mismatches of the optical parametric and sum-frequency generation processes, given by

Since the magnitudes of the wavevectors are given by k=ωn/c and since the refractive index depends on the angular frequency ω, the propagation constant mismatches are non-zero; this limits the coupling of the fields and ultimately the conversion efficiency into the red beam. To increase the coupling efficiency, the complex exponential factors appearing in Eqs. (1)–(3) must be compensated by the spatially varying nonlinearity, that is, χ(2)(z) must have a non-negligible Fourier component for both processes, given by (Robles-Agudo & Cudney, 2011)

where L is the length of the nonlinear medium. However, in order to generate the red beam the signal beam must be generated first, so it is necessary to control the ratio of the magnitudes of each of the Fourier components. We accomplish this by creating an aperiodically poled LiNbO3 crystal (APLN) that has the appropriate Fourier components (Kartaloğlu, Figen, & Aytür, 2003; Robles-Agudo & Cudney, 2011). We define
where w is a weighting parameter used to adjust the contribution of each of the Fourier components. From this function we design the APLN: we create a domain structure that follows g(z). If all of the waves have extraordinary polarization then χ(2)(z)=χ33(2)g(z).

We designed several domain structures with different values of w. Using the refractive indices predicted by the Sellmeier equation given in (Jundt, 1997), we calculate that kOPO=0.198 µm−1 and kSFG=0.383 µm−1 (corresponding to periodicities of 31.8 and 16.4μm), assuming operation at room temperature. These designs were transferred using standard photolithographic and electrical poling techniques (Cudney, Ríos, Arellanes, Alonso, & Fonseca, 2002) onto a 500μm thick, z-cut LiNbO3 wafer. After cutting and polishing, the crystal was 34mm long, and antireflection coatings for 2.2μm were deposited on the end facets. The crystal was placed in the experimental setup shown in Figure 1. As a pump we used a Nd:YAG laser that emits 12ns long (FWHM) pulses with a repetition rate of 10Hz. We used a half-wave plate (λ/2) and a Glan–Thompson polarizer (P) to vary the energy of the pump beam. In order to increase the conversion efficiency from the pump beam to the red beam, the APLN crystal was placed in a resonant cavity formed by two flat dielectric mirrors separated by 5.8cm which are highly reflective at the signal wavelength and highly transmitting at both the pump and red wavelengths, i.e. we made an OPO that oscillates at λ=2128nm.

Figure 1.

Experimental setup.

(0.06MB).

The maximum pump energy that can be used is determined by the damage threshold of the APLN crystal, which is approximately 3J/cm2. Since the APLN crystal is only 500μm thick, the maximum pump energy that can be used without damaging the sample is around 6mJ, assuming the beam has a circular cross section. In order to circumvent this restriction we focused the pump beam to an elliptical cross-section (0.34mm×2.8mm, FWHM) by using a pair of lenses, a 400mm focal length spherical lens (L1) and a 100mm focal length cylindrical lens (L2).

We obtained a red beam with all of the domain structures; in all cases it had a spectrum centered at 710nm with a large bandwidth (∼10nm FWHM) and a temporal duration of ∼9ns (FWHM) (Yankelevich, González, Cudney, Ríos, & Marcu, 2014). The output energy per pulse at 710nm vs. pump energy for the best two structures, one with w=0.20 and the other with w=0.34, is shown in Figure 2.

Figure 2.

Output energy of the red beam vs. pump energy.

(0.05MB).

As can be seen, in both cases the threshold to obtain the red beam is around 1mJ. However, above the threshold the conversion efficiency is higher for w=0.34. At a pump level of 7mJ per pulse we obtain 1mJ at 710nm, i.e. we have an efficiency of more than 14%.

We also studied the time evolution of the pulses. The red and pump beams were separated with a diffraction grating and the pulses were detected by fast rise-time photodiodes (the temporal resolution was limited by the bandwidth of the oscilloscope, 1GHz). The results are shown in Figure 3. Figure 3(a) shows the results obtained when the pump energy is just below the threshold; as can be expected, the red beam is not present. If the OPO is pumped above threshold, the red beam appears and the shape of the pump pulse at the output of the OPO is altered: the peak is depleted due to conversion of the pump into the signal and red beams, as shown in Figure 3(b) and (c). Finally, if the pump energy is several times the threshold, the pump beam is depleted but a secondary peak in the depletion zone appears, as shown in Figure 3(d). This is due to back conversion of the signal and red beams into the pump, which is indicative of a very high conversion of the pump into other wavelengths.

Figure 3.

Temporal profiles of the output pump and red beams. (a) Just below threshold; (b) and (c): above threshold; (d) above threshold, back conversion into the pump is observed. Each curve is the result of the running average over 100 pulses.

(0.18MB).

From the deformation of the pump pulse we can calculate how much of the pump is converted into other wavelengths. It can be readily shown that the fraction of the energy of the pump pulse that was not converted to other frequencies fp is given by (Arellanes & Cudney, 2001)

where Ep and Ip are the energy and the temporal profile of the pump pulse, and Epth and Ipth are the energy and the temporal profile at the threshold. The fraction of the input energy that is converted to other frequencies is simply 1−fp. Figure 4 shows the input energy converted to other wavelengths as a function of the input pump energy; for comparison, the energy of the red beam previously shown in Figure 2 is also shown. As can be seen, at 7mJ input energy over 67% is converted into other wavelengths, mainly the 2.12μm signal and the 710nm red beams.

Figure 4.

Energy converted to other frequencies.

(0.06MB).

In conclusion, we made a simple, inexpensive device that emits nanosecond pulses of broadband 710nm radiation, based on cascaded optical parametric oscillation at the degeneracy point and sum-frequency generation in a single aperiodically poled lithium niobate crystal. We obtained more than 1mJ of radiation at 710nm with only 7mJ of pump energy at 1.064μm.

Conflict of interest

The authors have no conflicts of interest to declare.

Acknowledgements

This work was partially supported by UC MEXUS collaborative grant CN 11-547 and by the project CB-2008-156542-F of CONACYT.

References
[Arellanes and Cudney, 2001]
M.O. Arellanes, R.S. Cudney.
Construcción y caracterización de un oscilador óptico paramétrico con niobato de litio periódicamente polarizado.
Revista Mexicana de Física, 47 (2001), pp. 460-466
[Cudney et al., 2002]
R.S. Cudney, L.A. Ríos, M.O. Arellanes, F. Alonso, J. Fonseca.
Fabricación de niobato de litio periódicamente polarizado para óptica no lineal.
Revista Mexicana de Física, 48 (2002), pp. 548-555
[De Mul et al., 1984]
F.F.M. De Mul, J. Van Spijker, D. Van der Plas, J. Greve, J.G. Aarnoudse, T.M. Smits.
Mini laser-Doppler (blood) flow monitor with diode laser source and detection integrated in the probe.
Applied Optics, 23 (1984), pp. 2970-2973
[Emelianov et al., 2006]
Emelianov, S.Y., Aglyamov, S.R., Karpiouk, A.B., Mallidi, S., Park, S., Sethuraman, S., Shah, J., Smalling, R.W., Rubin, J.M., & Scott, W.G. (2006). 1E-5 synergy and applications of combined ultrasound, elasticity, and photoacoustic imaging. InUltrasonics Symposium, 2006. IEEE (pp. 405–415). IEEE.
[Fgen and Akın, 2014]
Z.G. Figen, O. Akın.
Red beam generation based on aperiodically poled lithium niobate.
Optics Communications, 317 (2014), pp. 67-77
[Goldman et al., 1965]
L. Goldman, R.G. Wilson, P. Hornby, R.G. Meyer.
Radiation from a Q-switched ruby laser.
Journal of Investigative Dermatology, 44 (1965), pp. 69-71
[Grossman et al., 1996]
M.C. Grossman, C. Dierickx, W. Farinelli, T. Flotte, R.R. Anderson.
Damage to hair follicles by normal-mode ruby laser pulses.
Journal of the American Academy of Dermatology, 35 (1996), pp. 889-894
[Jundt, 1997]
D.H. Jundt.
Temperature-dependent Sellmeier equation for the index of refraction, ne, in congruent lithium niobate.
Optics Letters, 22 (1997), pp. 1553-1555
[Kang et al., 2011]
J. Kang, E.K. Kim, J.Y. Kwak, Y. Yoo, T.K. Song, J.H. Chang.
Optimal laser wavelength for photoacoustic imaging of breast microcalcifications.
Applied Physics Letters, 99 (2011), pp. 153702
[Kartaloğlu et al., 2003]
T. Kartaloğlu, Z.G. Figen, O. Aytür.
Simultaneous phase matching of optical parametric oscillation and second-harmonic generation in aperiodically poled lithium niobate.
Journal of the Optical Society of America B, 20 (2003), pp. 343-350
[Polla et al., 1987]
L.L. Polla, R.J. Margolis, J.S. Dover, D. Whitaker, G.F. Murphy, S.L. Jacques, et al.
Melanosomes are a primary target of Q-switch ruby laser irradiation in guinea pig skin.
Journal of Investigative Dermatology, 89 (1987), pp. 281-286
[Robles-Agudo and Cudney, 2011]
M. Robles-Agudo, R.S. Cudney.
Multiple wavelength generation using aperiodically poled lithium niobate.
Applied Physics B, 103 (2011), pp. 99-106
[Yankelevich et al., 2014]
D. Yankelevich, J.E. González, R.S. Cudney, L.A. Ríos, L. Marcu.
Development of a new pulsed source for photoacoustic imaging based on aperiodically poled lithium niobate.
Biomedical Optics Express, 5 (2014), pp. 468-473

Peer Review under the responsibility of Universidad Nacional Autónoma de México.

Copyright © 2015. Universidad Nacional Autónoma de México, Centro de Ciencias Aplicadas y Desarrollo Tecnológico
Descargar PDF
Opciones de artículo