metricas
covid
Buscar en
Revista Española de Medicina Nuclear e Imagen Molecular
Toda la web
Inicio Revista Española de Medicina Nuclear e Imagen Molecular 18F-FDG PET-TAC y sincronización respiratoria: efecto en la detección y catalo...
Información de la revista
Vol. 28. Núm. 4.
Páginas 181-187 (julio 2009)
Compartir
Compartir
Descargar PDF
English PDF
Más opciones de artículo
Vol. 28. Núm. 4.
Páginas 181-187 (julio 2009)
18F-FDG PET-TAC y sincronización respiratoria: efecto en la detección y catalogación de lesiones pulmonares
F-FDG PET-CT and respiratory sincronization: Effect in the detection and catalogation of pulmonary lesions
Visitas
6915
A.M.. García Vicentea, A.. Soriano Castrejóna, P.. Talavera Rubioa, V.M.. Poblete Garcíaa, A.. Palomar Muñoza, I.. Cepedello Boisoa, B.. González Garcíaa, J.M.. Cordero Garcíaa, M.. Bellón Guardiaa, J.P.. Pilkington Wolla
a Servicio de Medicina Nuclear, Hospital General de Ciudad Real, Ciudad Real, España
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (2)
Sin título

El movimiento respiratorio reduce la sensibilidad de la PET en la detección de lesiones pulmonares. La adquisición de la 18F-FDG PET-TAC sincronizada con el movimiento respiratorio (4D) puede salvar este inconveniente.

Nuestro objetivo fue determinar el efecto de la PET 4D en la actividad metabólica de la 18F-FDG así como en la catalogación final de lesiones pulmonares.

Material y métodos

Se ha valorado a 12 pacientes que presentaban 18 lesiones pulmonares con tamaños de entre 0,8 y 4cm. Se determinó el SUVmáx en imagen adquirida en condiciones estándares (3D) y el obtenido en el período del ciclo respiratorio con mayor actividad metabólica en imagen 4D. Se calculó el porcentaje de diferencia entre ambos. Asimismo, se evaluaron los cambios en la catalogación de las lesiones pulmonares (benignos o malignos) obtenidos al valorar la imagen PET 4D con respecto a la 3D.

Resultados

Diecisiete de las 18 lesiones pulmonares experimentaron un ascenso en su valor SUVmáx en la imagen 4D con respecto al estudio 3D. Cinco lesiones mostraron valores de SUVmáx superior a 2,5 en imagen 4D e inferior a 2,5 en imagen 3D. De éstas, 3 fueron correctamente catalogadas como malignas con la técnica 4D, aunque aumentó el número de falsos positivos a 2.

Conclusión

La adquisición de la 18F-FDG PET-TAC en 4D muestra valores de actividad metabólica más acordes con la realidad, permitiendo la clasificación correcta de lesiones malignas y reduciendo los falsos negativos aunque aumentando los falsos positivos.

Palabras clave:
Gating respiratorio
4D
Lesiones pulmonares
18F-FDG PET-TAC
Untitled

The respiratory movement reduces the sensitivity in the detection of pulmonary lesions. The synchroniced acquisition of PET with respiratory movement (4D) can reduce this inconvenient.

Our objective was assess the effect of 4D PET-CT in the metabolic activity of 18F FDG and final classification of pulmonary lesions.

Material and methods

12 patients with 18 pulmonary lesions with sizes within 0.8–4cm were assessed. The maximum SUV was obtained in the imaging acquired in standard conditions (3D) and the obtained in the respiratory period with higher metabolic activity in 4D images. The difference of percentage between both values was calculated. Moreover were evaluated the changes of the classification of pulmonary nodes (benign or malignant) obtained from the assessment of 4D and 3D PET images.

Results

17/18 pulmonary lesions showed an increase in the SUVmax value in the 4D with respect to 3D image. 5 lesions showed SUVmax values >2.5 in 4D image and <2 5 in 3d image from these 3 were correctly catalogued as malignant with 4d although the number of false positive increased to 2

Conclusion

18F-FDG 4D PET-CT shows values of metabolic activity more realistic allowing the correct classification reducing the false negative although increasing the false positive.

Keywords:
Respiratory gating
4D
Pulmonary lesions
18F-FDG PET-CT

Artículo

Opciones para acceder a los textos completos de la publicación Revista Española de Medicina Nuclear e Imagen Molecular
Socio
Si es usted socio de la Sociedad Española de Medicina Nuclear e Imagen Molecular (SEMNIM) puede acceder al texto completo de los contenidos de la Revista Española de Medicina Nuclear e Imagen Molecular desde los enlaces a la revista publicados en la web de la SEMNIN (enlace a https://semnim.es/iniciar-sesion/), previo inicio de sesión como socio. Si tiene problemas de acceso puede contactar con la Secretaría Técnica de la SEMNIM en el correo electrónico secretaria.tecnica@semnim.es o en el teléfono: + 34 619 594 780
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Revista Española de Medicina Nuclear e Imagen Molecular

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos

Quizás le interese:
10.1016/j.remn.2021.02.016
No mostrar más