metricas
covid
Buscar en
Revista Española de Medicina Nuclear e Imagen Molecular
Toda la web
Inicio Revista Española de Medicina Nuclear e Imagen Molecular Absorbed dose profiles for 32P, 90Y, 188Re, 177Lu, 153Sm and 169Er: radionuclide...
Información de la revista
Vol. 28. Núm. 4.
Páginas 188-192 (julio 2009)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Vol. 28. Núm. 4.
Páginas 188-192 (julio 2009)
Absorbed dose profiles for 32P, 90Y, 188Re, 177Lu, 153Sm and 169Er: radionuclides used in radiosynoviortheses treatment
Perfiles de dosis absorbida para 32P, 90Y, 188Re, 177Lu, 153Sm y 169Er : radionuclidos usados en el tratamiento de radiosinoviortesis
Visitas
2331
M.. Torresa, E.. Ayraa, O.. Albuernea, M.A.. Montano Delgadob
a Radiation Protection Department, Isotopes Centre, Carretera la Rada, Km 3 1/2 Havana, Cuba
b Hospital General Docente Enrique Cabrera, Havana, Cuba
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (2)

El principal objetivo de este trabajo fue obtener los perfiles de dosis para los radionúclidos de uso frecuente en radiosinoviortesis. Estos perfiles revelan la dosis absorbida impartida por unidad de actividad del radionúclido inyectado (Gy/h*MBq) en la membrana sinovial y el cartílago articular. Los radionúclidos seleccionados fueron 32P, 90Y, 188Re, 177Lu, 153Sm and 169Er. También fue calculado el rango terapéutico de cada radionúclido en el tejido sinovial. Este rango determina el grosor synovial que puede ser irradiado suficientemente y por lo tanto, tratado con éxito. Los valores S para la membrana sinovial y el cartílago articular fueron calculados usando como modelo un cilindro con la fuente distribuida uniformemente en su volumen. La membrana sinovial fue simulada variando el radio del cilindro (rango 0.5cm–9cm) y su altura (rango 0.01cm–0.04cm). La variación del radio del cilindro representa varios tamaños de superficie sinovial (articulaciones pequeñas, medianas y grandes), y se define como el área de la base del cilindro; la variación de la altura, representa diferentes estados de progresión de la artritis reumatoide. El mismo modelo fue empleado para la simulación del cartílago articular, pero la fuente fue uniformemente distribuida dentro de una capa cilíndrica (0.01cm) y 1cm de radio. Los resultados obtenidos permiten la estimación de la dosis que será entregada a la membrana sinovial y el cartílago articular para diferentes tamaños de articulación y diferentes estados de progresión de la artritis reumática.

Palabras clave:
Arthritis
Rheumatoid
Synovial membrane
Monte Carlo method
Radiation effects

The main objective of this paper was to obtain the absorbed dose profiles for radionuclides of frequent or potential use in radiosynoviortheses. These profiles reveal the absorbed dose per activity of injected radionuclide (Gy/h*MBq) in the synovial membrane and the articular cartilage. The researched radionuclides were 32P, 90Y, 188Re, 177Lu, 153Sm and 169Er. The therapeutic range of each radionuclides in synovial tissue were also calculated. This range determines the synovial thickness that can be sufficiently irradiated and thus successfully treated. The S values for the synovial membrane and articular cartilage were calculated using as a model a cylinder with the source uniformly distributed in its volume. The synovial membrane was simulated varying the radius of the cylinder (from 0.5cm to 9cm) and its height (from 0.01cm to 0.04cm). The area in the base of the cylinder represents different sizes of the synovial surface (small, medium and large joints). The height of the cylinder represents different stages of the progression of the rheumatoid arthritis. The same model was used to simulate the articular cartilage but, the source was uniformly distributed into a cylindrical slab (0.01cm height and 1cm of radius. The results obtained allow the estimation of the dose that will be delivered to the synovial membrane and the articular cartilage for different joint sizes and different stages of progression of the rheumatoid arthritis (RA).

Artículo

Opciones para acceder a los textos completos de la publicación Revista Española de Medicina Nuclear e Imagen Molecular
Socio
Si es usted socio de la Sociedad Española de Medicina Nuclear e Imagen Molecular (SEMNIM) puede acceder al texto completo de los contenidos de la Revista Española de Medicina Nuclear e Imagen Molecular desde los enlaces a la revista publicados en la web de la SEMNIN (enlace a https://semnim.es/iniciar-sesion/), previo inicio de sesión como socio. Si tiene problemas de acceso puede contactar con la Secretaría Técnica de la SEMNIM en el correo electrónico secretaria.tecnica@semnim.es o en el teléfono: + 34 619 594 780
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Revista Española de Medicina Nuclear e Imagen Molecular

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos