metricas
covid
Buscar en
Revista Española de Medicina Nuclear e Imagen Molecular
Toda la web
Inicio Revista Española de Medicina Nuclear e Imagen Molecular Estabilidad de alimento sólido marcado con diferentes radiofármacos para vacia...
Información de la revista
Vol. 23. Núm. 5.
Páginas 343-346 (septiembre 2004)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Vol. 23. Núm. 5.
Páginas 343-346 (septiembre 2004)
Estabilidad de alimento sólido marcado con diferentes radiofármacos para vaciamiento gástrico
The stability of labeled solid food with different radiopharmaceutical for gastric emptying
Visitas
3931
T. Martíneza, D. Beníteza, JA. Nuño de la Rosaa, T. Fuentea
a Unidad de Radiofarmacia. Servicio de Medicina Nuclear. Hospital Universitario Virgen de la Arrixaca. Murcia.
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Tablas (3)
Tabla 1. CARACTERISTICAS E INDICACIONES DE LOS RADIOFARMACOS INCLUIDOS EN EL PRESENTE ESTUDIO
Fig. 1. --Porcentaje de actividad inicial ligada a alimento sólido que permanece unida al mismo, tras 120 minutos de digestión en medio gástrico simulado, para cada uno de los radiofármacos estudiados.
Fig. 2. --Estabilidad de marcaje de cada radiofármaco, como porcentaje de pureza radioquímica que mantiene, cada uno de ellos, tras 120 minutos de digestión en medio gástrico simulado.
Mostrar másMostrar menos
Objetivo: El azufre coloidal 99mTc-SC radiofármaco de elección para estudios de vaciamiento gástrico de sólidos no está disponible en nuestro país. Ello nos ha llevado a valorar la estabilidad de unión a alimento sólido de siete radiofármacos que podrían presentar a priori adecuada fijación al mismo. Material y método: Hemos estudiado la estabilidad de unión a alimento sólido en tortilla de siete radiofármacos marcados con 99mTc (MAA, estaño coloidal, macro y nanocoloide de sulfuro de renio, micro y nanocoloide de albúmina y nanocoloide de azufre) mediante medida de la actividad disociada del mismo tras dos horas de digestión en medio gástrico simulado (120' en agitación a 37°, en HCl 0,1 M). Asímismo, y en idénticas condiciones, hemos determinado su estabilidad de marcaje por medida de su pureza radioquímica, obtenida por ITLC. Resultados: En estas condiciones los MAA, el macrocoloide de sulfuro de renio, el microcoloide de albúmina y el nanocoloide de albúmina presentan el mejor comportamiento, con una actividad ligada a alimento superior al 90 % de la fijada inicialmente. Conclusiones: De los resultados obtenidos no se ha podido establecer ninguna relación entre tamaño o composición del radiofármaco y la estabilidad de su unión al sólido. Dado que el sulfuro de renio ha suspendido recientemente su producción y los tres radiofármacos restantes, con estabilidad de unión al alimento sólido superior al 90 %, no incluyen las exploraciones digestivas entre sus indicaciones, existe actualmente en nuestro país una considerable limitación legal para realizar estudios de esta naturaleza.
Palabras clave:
Vaciamiento gástrico sólidos
Estabilidad unión trazador-alimento
Objective: Sulfur colloid 99mTc-SC, the radiopharmaceutical of choice for solid gastric emptying studies, is not available in our country. It has led us to assess the solid binding stability of seven alternative radiopharmaceuticals that could present adequate fixation to it a priori. Materials and method: The stability of labelled solid food with seven colloidal 99mTc-radiopharmaceuticals of different sizes and nature (MAA, tin colloid, rhenium sulphide macrocolloid, albumin microcolloid, sulfur nanocolloid, albumin nanocolloid and rhenium sulfur nanocolloid) has been studied by measuring their dissociated activity after two hours digestion in simulated gastric fluid (kept 120' in agitation, in HCl 0,1 M at 37°). The survey also assesses radiopharmaceutical labelling stability after two hours digestion in identical conditions by measuring their radiochemical purity in ITLC. Results: In these conditions, MAA, rhenium sulphide macrocolloid, albumin microcolloid and albumin microcolloid present the best behaviour, with an activity linked to food over 90 % of the previously fixed activity. Conclusions: According to the results, there is no relationship between the radiopharmaceutical size and nature and the stability of its binding to the solid food. Because rhenium sulphide macrocolloid is no longer manufactured and the other three radiopharmaceuticals which have a binding stability to the solid food over 90 % do not include digestive explorations amongst their indications, nowadays, there is a serious legal limitation to carry out this type of studies in our country.
Keywords:
Solid gastric emptying
Tracer-food binding stability

Artículo

Opciones para acceder a los textos completos de la publicación Revista Española de Medicina Nuclear e Imagen Molecular
Socio
Si es usted socio de la Sociedad Española de Medicina Nuclear e Imagen Molecular (SEMNIM) puede acceder al texto completo de los contenidos de la Revista Española de Medicina Nuclear e Imagen Molecular desde los enlaces a la revista publicados en la web de la SEMNIN (enlace a https://semnim.es/iniciar-sesion/), previo inicio de sesión como socio. Si tiene problemas de acceso puede contactar con la Secretaría Técnica de la SEMNIM en el correo electrónico secretaria.tecnica@semnim.es o en el teléfono: + 34 619 594 780
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Revista Española de Medicina Nuclear e Imagen Molecular

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos