metricas
covid
Buscar en
Revista Española de Medicina Nuclear e Imagen Molecular
Toda la web
Inicio Revista Española de Medicina Nuclear e Imagen Molecular Evaluación cuantitativa del SPET con 123I-FP-CIT: validación de un método sem...
Información de la revista
Vol. 24. Núm. 4.
Páginas 244-249 (julio 2005)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Vol. 24. Núm. 4.
Páginas 244-249 (julio 2005)
Evaluación cuantitativa del SPET con 123I-FP-CIT: validación de un método semiautomático
Quantitative evaluation of 123I-FP-CIT SPECT: validation of a semiautomated method
Visitas
2492
C. Lorenzo i Bosqueta, G. Cuberas Borrósa, F. Miquel Rodríguezb, P. Caresiaa, S. Aguadé Bruixa, J. Castell Conesaa
a Servei de Medicina Nuclear. Hospital Universitari Vall d'Hebron. Barcelona.
b Servei de Neurologia. Unitat de Trastorns del Moviment. Hospital Universitari Vall d'Hebron. Barcelona.
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (3)
Mostrar másMostrar menos
Tablas (4)
Tabla 1. REPRODUCTIBILIDAD INTEROBSERVADOR EN PACIENTES CON SPET DE 123I-FP-CIT PATOLOGICO (n = 25)
Tabla 2. ÍNDICES DE CAPTACION DEL ESTRIADO VS EL OCCIPITAL EN EL GRUPO CON CAPTACION CUALITATIVAMENTE CONSERVADA (n = 25)
Tabla 3. ÍNDICES DE CAPTACION DEL PUTAMEN VS EL OCCIPITAL EN LOS PACIENTES Y EN EL GRUPO CON CAPTACION CUALITATIVAMENTE CONSERVADA
Tabla 4. ÍNDICES DE CAPTACION DEL CAUDADO VS EL OCCIPITAL EN LOS PACIENTES Y EN EL GRUPO CON CAPTACION CUALITATIVAMENTE CONSERVADA
Mostrar másMostrar menos
Objetivo: Valorar la utilidad de un método de cuantificación de la captación de 123I-FP-CIT mediante la definición de unos valores de referencia, la validación del rango de normalidad y la variación interobservador. Pacientes y método: Se seleccionan 50 pacientes con un SPET con 123I-FP-CIT: 25 patológicos con el diagnóstico clínico de una enfermedad de Parkinson y 25 estudios cualitativamente normales, con el diagnóstico de catorce con un parkinsonismo farmacológico y once con un parkinsonismo psicogénico. En los cortes transversales, se seleccionó el corte central que mejor visualiza los núcleos de la base, y sobre éste se posicionan las áreas de interés (Region Of Interest-ROI) estandarizadas. Se calcularon los índices de captación específica (caudado y putamen) vs no específica (occipital) y las ratios de lateralidad. Se determinaron las variables cuantitativas (media, la desviación estándar y el rango) de ambos grupos, el percentil 10, el percentil 90 y el coeficiente de variación y de correlación entre los resultados de dos observadores. Resultados: Los coeficientes de variación interobservador obtenidos oscilaron entre 3,24 y 5,61. Se obtuvieron unos coeficientes de correlación entre 0,89 y 0,99. El dintel de separación estimado entre ambas poblaciones en el putamen fue en el derecho de 2,10 y en el izquierdo de 2,05. Con respecto a los caudados, existió un solapamiento entre ambas poblaciones que no permitió establecer un límite de separación. Conclusiones: Este método de cuantificación es reproducible, permite definir unos valores de referencia y determinar el límite de la normalidad.
Palabras clave:
123I-FP-CIT
SPET
Parkinsonismo
ROI
Transportadores dopamina
Objective: To assess the utility of a quantification of the 123I-FP-CIT uptake by the definition of some reference values, normal range values and interobserver variation. Patients and method: Fifty patients with a 123I-FP-CIT SPECT: 25 patients had a pathological SPECT with the diagnosis of Parkinson's disease and the remaining had a qualitative normal SPET, with the diagnosis of 14 drug-induced Parkinsonism and 11 with psychogenic Parkinsonism. In the transversal slices, the best central slice that showed the nuclei of the base best was selected and standard ROIs (Region Of Interest) were applied. Specific (caudate and putamen) versus non specific (occipital) and laterality ratios were calculated. A normal statistical analysis for independent quantitative samples was used (mean, standard deviation and range) as well as variation coefficient and correlation coefficient of two observers and the 10th and 90th percentile. Results: The variation coefficient interobserver was 3.24-5.61 and the correlation coefficient was 0.89-0.99. Cut-off values between both populations were established at 2.10 in the right putamen and at 2.05 in the left. Cut-off values definition in caudate were not assessable due to overlapping of ratios of both populations. Conclusions: This quantification method is highly reproducible. It makes it possible to obtain reference values and to define normal range.
Keywords:
[ 123I]-FP-CIT
SPET
Parkinsonism
ROI
Dopamine transporters

Artículo

Opciones para acceder a los textos completos de la publicación Revista Española de Medicina Nuclear e Imagen Molecular
Socio
Si es usted socio de la Sociedad Española de Medicina Nuclear e Imagen Molecular (SEMNIM) puede acceder al texto completo de los contenidos de la Revista Española de Medicina Nuclear e Imagen Molecular desde los enlaces a la revista publicados en la web de la SEMNIN (enlace a https://semnim.es/iniciar-sesion/), previo inicio de sesión como socio. Si tiene problemas de acceso puede contactar con la Secretaría Técnica de la SEMNIM en el correo electrónico secretaria.tecnica@semnim.es o en el teléfono: + 34 619 594 780
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Revista Española de Medicina Nuclear e Imagen Molecular

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos