covid
Buscar en
Revista Mexicana de Ortodoncia
Toda la web
Inicio Revista Mexicana de Ortodoncia Comparative study between cone-beam and digital lateral head film cephalometric ...
Información de la revista
Vol. 3. Núm. 2.
Páginas e84-e87 (abril - junio 2015)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Visitas
1887
Vol. 3. Núm. 2.
Páginas e84-e87 (abril - junio 2015)
ORIGINAL RESEARCH
Open Access
Comparative study between cone-beam and digital lateral head film cephalometric measurements
Estudio comparativo entre mediciones cefalométricas en cone-beam y radiografíalateral digital
Visitas
1887
Jansen Valeria Ramírez Huerta1,
Autor para correspondencia
cdjansenvrh@hotmail.com

Corresponding author.
, José Guillermo Oropeza Sosa2, Abigailt Flores Ledesma3
Division of Postgraduate Studies and Research (DEPeI) of the Faculty of Dentistry (FD), National Autonomous University of Mexico (UNAM)
Contenido relaccionado
Revista Mexicana de Ortodoncia. 2015;3:84-710.1016/j.rmo.2016.03.023
Jansen Valeria Ramírez Huerta, José Guillermo Oropeza Sosa, Abigailt Flores Ledesma
Este artículo ha recibido

Under a Creative Commons license
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (1)
Tablas (4)
Table I. Definition of variables.
Table II. Mean and standard deviation between parenthesis.
Table III. Mean and standard deviation between parenthesis.
Table IV. Tukey test for mandibular length.
Mostrar másMostrar menos
ABSTRACT
Objective

The objective of the present study was to determine the differences between cephalometric measurements obtained by two different methods: cone-beam tomography and digital lateral head film.

Material and methods

Measurements were performed (anterior facial height, mandibular length, upper incisor to the A-Pog line, lower incisor to the A-Pog line, ANS-PNS, ANB angle) on 30 patients by means of lateral digital radiography and cone-beam. The statistic test used was the t-Student.

Results

The measurement that presented a statistically significant difference was the mandibular length (p = 0.001).

Conclusion

Measurements performed in cone-beam scans for a 3D cephalometric analysis did not show evidence of being more effective or reliable in comparison with measurements performed in 2D.

Keywords:
Cone-beam
lateral head film
cephalometry
reliability
RESUMEN
Objetivo

El objetivo del presente estudio fue determinar las diferencias de las mediciones cefalométricas realizadas por dos métodos diferentes: cone-beam y la radiografía lateral de cráneo.

Material y métodos

Se realizaron mediciones (altura facial anterior, longitud mandibular, incisivo superior a A-pg, incisivo inferior a A-pg, ENA-ENP, ANB) de 30 pacientes por medio de radiografía lateral digital y cone-beam, se usó la prueba t-Student.

Resultados

La longitud mandibular del lado derecho e izquierdo del cone-beam presentó diferencia estadísticamente significativa con las radiografías laterales (p = 0.001).

Conclusión

La mediciones realizadas en tomografías para la realización de un trazado cefalométrico en 3D no presentaron una evidencia de una mayor eficacia y fiabilidad en comparación a las medidas realizadas en 2D.

Palabras clave:
Cone-beam
radiografía lateral
cefalometría
confiabilidad
Texto completo
INTRODUCTION

Radiographic imaging is an important diagnostic tool for the orthodontic patient's assessment; since the introduction of cephalometry by Brodie n 1931, cephalometry has contributed to the analysis of both dental and skeletal malocclusions and has become a standardized diagnostic method in orthodontic practice and in research since it provides a detailed morphological analysis through the sagittal and vertical evaluation of bony, dental and soft tissues. Likewise, it permits a thorough analysis of growth through the comparison of cephalograms in different time intervals or by means of predictions.1,2

Conventionally, cephalometric analysis is performed in geometric projections of a 2D radiograph in which landmarks for bone and dental structures are identified. These projections present some difficulties such as:3,4

  • Distortion: it is the result of an inadequate patient's head orientation in the cephalostat, incorrect aligning of the film or the central beam.

  • Magnification: it is defined as the enlargement of an object's real size. The factors that influence enlargement are the size of the silver halide crystals in the emulsion or several characteristics of the intensifying screens.4

Cone-beam computerized tomography (CBCT) is a technology initially developed for angiographs in 1982 and was subsequently applied in maxillofacial imaging.

Since 1990 it was possible to manufacture smaller and less expensive clinical systems.3

The advantages of CBCT is that it allows the clinician to locate cephalometric points in 3D images in order to personalize cephalometric analysis with linear and angular measurements on the left and right side of the patient.5,6

One of the most important advantages is the localization of cephalometric landmarks through cone-beam imaging. Their location can be described in the three planes of space: sagittal, axial and coronal.7–10

In 1995 Jacobson and Gereb developed a 3D cephalometric analysis which was capable of accurately measuring oral and facial surfaces in three dimensions. This program defined distances between anatomical landmarks.4

Among the disadvantages of cone-beam imaging is the high dose of radiation that the patient receives. However it should be considered that for an orthodontic patient, additional radiographs may be required such as a panoramic X-Ray or lateral head film which in sum result in higher doses of radiation compared to those of the cone-beam.7,10

The objective of this study was to determine the differences between linear cephalometric measurements performed on conventional lateral radiographs and in cone beam scans of patients who attended the Orthodontics clinic of the Division of Postgraduate Studies and Research, Faculty of Odontology, UNAM, between the years of 2011 and 2013.

MATERIALS AND METHODS

To conduct this study, thirty-two patients who attended the Orthodontics Clinic in the scholar year 2011-2013, who signed an informed consent and had digital lateral head films or cone-beam scans were randomly selected. Inclusion criteria were the radiographs of patients with complete permanent dentition, without any syndrome regardless of the gender.

Radiographs and CBCT that were not taken with the cephalostat orthopos XG plus and the NewTom VGI tomograph were excluded. Digital radiographs were taken with the orthopos XG Plus cephalostat under the following conditions: 25 KVa, 15mA and an exposure time of 0.04 second.

The CBCT were taken with a NewTom VGI tomograph, at 70 Kv, 1-20mA amperage, 3.6 to 5.4seconds exposure with a sensor of 15 x 15cm and a 0.03 x 0.03 x 0.03 Voxel measurement.

The following linear measurements were analyzed: anterior facial height, right side and the left side mandibular length, nasal spine length, upper and lower incisor to plane A-P of the right side and on the left side. The angular measurement was ANB (Table I).

Table I.

Definition of variables.

Measurements  Definition 
Anterior facial height  Plane formed by Nasion and Menthon points 
Mandibular plane  Tangent line to the mandibular lower rim that connects Me point with the lowest point of the mandibular ramus 
Upper incisor to A-Pg  Distance between the most labial portion of the upper centralincisor and the A-Pg plane 
Lower incisor to A-Pg  Distance between the most labial portion of the lower central r incisor and the A-Pg plane 
ANS-PNS  Distance between the anterior nasal spine point and the posterior nasal spine point 
ANB  Angle formed by the NA-point B plane and the NA-point A plane 

The linear and angular measurements in the digital radiographs were obtained through the Nemotec Dental Studio NX program software (Nemotec Software 2005, SL, Madrid, Spain) while the Conebeam were obtained through the viewfinder OnDemand.

Each of the measurements was taken twice with a difference of two weeks between them and they were performed by a single operator. The statistical analysis was obtained with SPSS version 15 using a Student's t-test and ANOVA with a post-hoc Tukey test.

RESULTS

The operator performed previous tests for measurement calibration; an intraclass correlation coefficient (ICC) was used thus obtaining a 0.83 to 0.99 reliability. Once the calibration was performed, the measurements for the study were obtained.

A Kolmogorov-Smirnov test was used to determine data distribution. According to the results, the statistical tests would be parametric.

The anterior facial height, ANS-PNS and ANB in the lateral head film and in the cone-beam were compared using a Student's t-test (p < 0.05). No statistically significant differences were found (Table II). Subsequently, the mandibular length, upper incisor to A-Po and lower incisor to A-Po were compared in the lateral head film and in the right side and left side cone-beam using the ANOVA test (p < 0.05) (Table III).

Table II.

Mean and standard deviation between parenthesis.

Variable  Lateral headfilm  Cone-beam 
Anterior facial height  117.98 (9.73)  117.9 (8.51)  0.842 
ANS-PNS  49.21 (3.74)  50.53 (2.85)  1.39 
ANB  3.81 (5.61)  50.53 (2.85)  1.39 
Table III.

Mean and standard deviation between parenthesis.

Variable  Lateral headfilm  Right Cone-beam  Left Cone-beam 
Mandibular length  67.22 (6.62)  85.07 (5.52)  86.18 (2.84)  0.001 
Upper incisor to A-Pg  7.07 (2.65)  7.93 (2.24)  8.67 (2.24)  0.68 
Lower incisor to A-Pg  4.50 (3.08)  5.76 (2.75)  5.19 (2.30)  0.221 

Statistically significant differences were found in the mandibular length. The post hoc Tukey test was conducted and a statistically significant difference was found between the lateral head film and the right-side cone-beam and the lateral head film and the left side cone-beam (p > 0.05) (Table IVandFigure 1).

Table IV.

Tukey test for mandibular length.

Variable 
Radiograph versus right cone-beam  0.001 
Radiograph versus left cone-beam  0.001 
Right cone-beam versus left cone-beam  0.756 
Figure 1.

The upper lines show the groups with Tukey statistically significant differences (p < 0.05).

(0,18MB).
DISCUSSION

There are several programs available that perform 3D cephalometry. These programs are costly and their use is complex; CBCT are usually equipped with viewfinders that allow measurement realization. However, some of the viewfinders like the one used in this study, exhibit limitations, such as the difficulty for carrying out measurements on internal structures. Nevertheless, they provide the ability to perform many other measurements both linear and angular.

Identification of anatomical landmarks in 3D images is complex because currently, there is no standard for proper identification features. Kumar et al10 pointed out that the evaluation of 3D anatomical landmarks is under development; according to the author, transition from 2D to 3D could be achieved through the synthesis of obtained CBCT Cephalograms.

The results of the statistical analysis clearly show a difference in the mandibular length, given that this measurement performed in radiographs is linear. Since the mandibular structure often presents curvatures, cone-beam measurements provide a more natural and accurate structure identification.

The accuracy and precision of cephalometric measurements in 3D images obtained from computerized tomography has been assessed in different ways by several authors.5,10–13 Moreira et al.13 concluded that there were no statistical significant differences between measurements taken in cone-beam and lateral head films of dry skulls. Our study agrees with this author's results.

Grauer et al,14 conducted a study in 2010 in which the cephalometric measurements obtained from digital lateral radiographs were compared with those obtained from CBCT. Grauer's results were the same as those obtained by this study. We conclude that the similarity of the results is due to the fact that the same programs were used for obtaining the measurements.

Shokri et al15 in 2014 conducted an in vitro study in which they found a statistically significant difference in mandibular length, similar to this study. However they found a statistically significant difference in the anterior facial height, which differs from our results. In the study by Shokri et al a statistically significant difference was also found in the ANS-S measurement that was not considered in this study due to the fact that the program used did not have the option of marking internal structure anatomical points.

CONCLUSIONS

The measurements in CBCTs for the realization of a 3D cephalometric tracing did not demonstrate a clear evidence of more efficiency and reliability in comparison to the measurements performed in 2D images.

Cone-beam tomography requires a higher radiation dose in comparison to digital radiography. For these reasons, their use should be limited to specific indications, such as patients with impacted teeth, facial asymmetries, and craniofacial anomalies or to determine the morphology of the temporomandibular joint among others.

RECOMMENDED READINGS
[Damstra et al., 2011]
J. Damstra, Z. Fourie, J.J. Huddleston Slater, Y. Ren.
Reliability and the smallest detectable difference of measurements on 3-dimensional cone-beam computed tomography images.
Am J Orthod Dentofacial Orthop, 140 (2011), pp. e107-e114
[Halazonetis, 2005]
D.J. Halazonetis.
From 2-dimensional cephalograms to 3-dimensional computed tomography scans.
Am J Orthod Dentofacial Orthop, 127 (2005), pp. 627-637
[Swennen and Schutyser, 2006]
G.R. Swennen, F. Schutyser.
Three-dimensional cephalometry: spiral multi-slice vs cone-beam computed tomography.
Am J Orthod Dentofacial Orthop, 130 (2006), pp. 410-416
[Yu et al., 2008]
Yu SH, Nahm DS, Baek SH. Reliability of landmark identification on monitor-displayed lateral cephalometric images. Am J Orthod Dentofacial Orthop. 2008; 133: 790.e1-6. http://www.nemotec.com/nemoceph3D-0S_catalogo.php.
REFERENCES
[1]
Athanasios Athanasiou. Orthodontic cephalometry. Mosby Wolfe 1995.
[2]
Jacobson A, Richard L. Radiographic cephalometry from basics to 3 D Chicago Quintessence books; 2006.
[3]
J. Ahlgvist, S. Eliasson, U. Welander.
The effect of projection errors on cephalometric length measurements.
Eur J Orthod., 8 (1986), pp. 141-148
[4]
G.R.J. Swennen, F. Schutyser.
Three dimensional cephalometry.
Belgium, (2005),
[5]
V. Kumar, LudlowJ, C.L.H. Soares.
In vivo comparison of conventional and cone beam CT synthesized cephalograms.
Angle Orthod., 78 (2008), pp. 873-879
[6]
W.J. Houston.
The analysis of errors in orthodontic measurements.
Am J Orthod., 83 (1983), pp. 382-390
[7]
R. Navarro, L. de, P.V. Oltramari-Navarro, T.M. Fernandes.
Comparison of manual and digital lateral CBCT cephalometric analyses.
J Appl Oral Sci., 2 (2013), pp. 167-176
[8]
D. Grauer, L.S. Cevidanes, W.R. Proffit.
Working with DICOM craniofacial images.
Am J Orthod Dentofacial Orthop., 136 (2009), pp. 460-470
[9]
L.Q. Bruntz, J.M. Palomo, S. Baden, M.G. Hans.
A comparison of scanned lateral cephalograms with corresponding original radiographs.
Am J Orthod Dentofacial Orthop., 130 (2006), pp. 340-348
[10]
V. Kumar, J.B. Ludlow, A. Mol, L. Cevidanes.
Comparison of conventional and cone beam CT synthesized cephalograms.
Dentomaxillofac Radiol., 36 (2007), pp. 263-269
[11]
P.M. Cattaneo, C.B. Bloch, D. Calmar, M. Hjortshoj, B. Melsen.
Comparison between conventional and cone-beam computed tomography-generated cephalograms.
Am J Orthod Dentofacial Orthop., 134 (2008), pp. 798-802
[12]
P. Pittayapat, N. Limchaichana-Bolstad, G. Willems, R. Jacobs.
Three-dimensional cephalometric analysis in orthodontics: a systematic review.
Orthod Craniofac Res., 17 (2014), pp. 69-91
[13]
C.R. Moreira, M.A. Sales, P.M. Lopes.
Assessment of linear and angular measurements on three-dimensional cone-beam computed tomographic images.
Oral Surg Oral Med Pathol Oral Radiol Endod., 108 (2009), pp. 430-436
[14]
D. Grauer, L.S. Cevidanes, M.A. Styner, I. Heulfe, E.T. Harmon, H. Zhu, et al.
Accuracy and landmark error calculation using cone-beam computed tomography-generated cephalograms.
Angle Orthod., 80 (2010), pp. 286-294
[15]
A. Shokri, S. Khajeh, A. Khavid.
Evaluation of the accuracy of linear measurements on lateral cephalograms obtained from cone-beam computed tomography scans with digital lateralcephalometric radiography: an in vitro study.
J Craniofac Surg., 25 (2014), pp. 1710-1713

This article can be read in its full version in the following page: http://www.medigraphic.com/ortodoncia

Postgraduate student.

Professor.

Professor at the Dental Materials Laboratory.

Copyright © 2015. Universidad Nacional Autónoma de México, Facultad de Odontología
Opciones de artículo