metricas
covid
Buscar en
Annals of Hepatology
Toda la web
Inicio Annals of Hepatology Chronic Hepatitis C Patients with Obesity: Do We Need Two Operators for Accurate...
Información de la revista
Vol. 17. Núm. 5.
Páginas 795-801 (septiembre - octubre 2018)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Visitas
1979
Vol. 17. Núm. 5.
Páginas 795-801 (septiembre - octubre 2018)
Open Access
Chronic Hepatitis C Patients with Obesity: Do We Need Two Operators for Accurate Evaluation of Liver Stiffness?
Visitas
1979
Gamal E. Shiha
,,
Autor para correspondencia
g_shiha@hotmail.com

Correspondence and reprint request:
, Shahira El-Etreby, Mounir Bahgat, Magdy Hamed, Mohamed El Sherbini, Elsayed A. Ghoneem, Khaled Zalata, Reham E. Soliman*,§, Mohamed A. ElBasiouny*,, Nabiel NH Mikhail*,||
* Egyptian Liver Research Institute and Hospital (ELRIH), Sherbin, El Mansoura, Egypt
Hepatology and Gastroenterology Unit, Internal Medicine. Department, Faculty of Medicine, Mansoura University, Egypt
Pathology Department, Faculty of Medicine, Mansoura University, Egypt
§ Tropical Medicine Department, Faculty of Medicine, Port Said University, Egypt
|| Department of Biostatistics, South Egypt Cancer Institute, Assiut University, Egypt
Este artículo ha recibido

Under a Creative Commons license
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (2)
Tablas (3)
Table 1. Baseline characteristics of studied patients.
Table 2. Patient (n) staged for liver fibrosis by FibroScan performed by both operators based on the score system proposed by Ziol, et al. 2005.8
Table 3. Risk factors associated with concordance/discordance on fibrosis staging based TE between the two operators.
Mostrar másMostrar menos
Abstract

Introduction and aim. Transient elastography is gaining popularity as a non-invasive method for predicting liver fibrosis, but inter observer agreement and factors influencing reproducibility have not been adequately assessed.

Material and methods. This cross-sectional study was conducted at Specialized Medical Hospital and the Egyptian Liver Foundation, Mansoura, Egypt. The inclusion criteria were: age older than 18 years and chronic infection by hepatitis C. The exclusion criteria were the presence of ascites, pacemaker or pregnancy. Three hundred and fifty-six patients participated in the study. Therefore, 356 pairs of exams were done by two operators on the same day.

Results. The overall inter observer agreement ICC was 0.921. The correlation the two operators was excellent (Spearman’s value q = 0.808, p < 0.001). Inter-observer reliability values were κ = 0.557 (p < 0.001). A not negligible discordance of fibrosis staging between operators was observed (87 cases, 24.4%). Discordance of at least one stage and for two or more stages of fibrosis occurred in 60 (16.9%) and 27 cases (7.6%) respectively. Obesity (BMI ≥ 30 kg/m2) is the main factor associated with discordance (p = 0.002).Conclusion. Although liver stiffness measurement has had an excellent correlation between the two operators, TE presented an inter-observer variability that may not be negligible.

Keywords:
Transient elastography
FibroScan
Inter observer variability
Chronic hepatitis C
BMI
Texto completo
Introduction

The accurate diagnosis of chronic hepatitis C (CHC) related fibrosis is crucial for prognosis and treatment decisions, and is currently best evaluated by histological examination of liver biopsy.1,2 However, liver biopsy has several disadvantages, including poor patient compliance, sampling errors, limited usefulness for dynamic follow-up, and a risk of complications typical of invasive procedures. In addition, the predictive power of histology may be weakened by sampling variability.37 Together, these constraints of liver biopsy have encouraged the search for non-invasive methods to assess progression of fibrosis. The ideal noninvasive technique should be valid, painless, reproducible, easy-to-learn, easy-to-perform and cheap. There is an interest in developing methods, either serological or imaging, which is all non-invasive, in order to determine the presence and degree of fibrosis. Among these new techniques are serum markers and unidimensional transient elastography (FibroScan).

Transient elastography (TE) using FibroScan is a noninvasive, and reproducible technique that evaluates tissue stiffness. Liver stiffness measurement (LSM) has been demonstrated to be a reliable tool for assessing hepatic fibrosis and cirrhosis, especially in patients with chronic hepatitis.812

Obesity is one of the most significant public health problems faced by people from industrialized countries and is rapidly catching up in developing countries also. In 2016, it is estimated that more than 1.9 billion adults were overweight with 650 million obese.13

In clinical practice, the applicability of FibroScan is particularly influenced by the expertise of the operator14 and the body mass index (BMI) of the patient.15 According to The World Federation for Ultrasound in Medicine and Biology, 201516 the main limitation to the use of TE in clinical practice is its limited applicability in patients with obesity. The use of the XL probe reduces the failure rate in them but results in a high rate of unreliable results (approximately 25%). Subcutaneous adipose tissue attenuates the transmission of the shear wave into the liver and the ultrasonic signal to measure the propagation speed. Therefore, numerous studies have shown that obesity is the strongest predictor of failure or unreliable LSM.17

In Egypt, where the HCV prevalence is the highest in the world,18 the National recommendations required that HCV-infected patients undergo a liver biopsy at the initial evaluation and that a treatment is offered to patients with a fibrosis rate ≥ F2. Egypt moved to mass treatment of HCV, but still, liver fibrosis determines the type and duration of treatment. Having a cheaper and more acceptable alternative to liver biopsy is critical in a country where six million individuals are chronically infected with HCV.19 However, these new noninvasive methods should be locally evaluated, as circulating virus genotype (genotype 4), increased body mass index highly prevalent in Egypt, and co-infections with schistosomiasis may interfere with liver fibrosis assessment. The national plan of action for prevention, care and treatment of viral hepatitis in Egypt (2014-2018) suggested the use of noninvasive methods (FibroScan and FIB4) for evaluation of viral hepatitis patients.20 Uncertainties still exist regarding reliability and reproducibility of TE.21,22

The present study aimed to evaluate the inter observer variability in TE in patients with CHC, obtained on the same day, by two experimented operators and the factors affecting this variability.

Material and MethodsStudy design

This cross-sectional study was conducted at Specialized Medical Hospital and the Egyptian Liver Foundation, Mansoura, Egypt. The inclusion criteria were; age older than 18 years and chronic infection by hepatitis C that characterized by the presence of HCV-RNA in blood serum. The exclusion criteria were the presence of ascites, pacemaker or pregnancy. Three hundred and fifty-six consecutive patients with CHC participated in the study. Therefore, 356 pairs of exams were done by two operators at the same day and before the start of any anti-HCV treatment. Both operators have realized more than 500 exams previously, being classified as experienced operators.15

Ethical considerations

This study protocol was conducted in accordance with the Helsinki Declaration and was approved by Mansoura Faculty of Medicine Ethics Committee. All patients signed an informed consent upon enrolment in this study.

Transient elastography (TE)

The procedures were performed by two independent investigators on the same day. The right lobe of the liver was accessed through an intercostal space while the patient was lying down in the dorsal decubitus position with the right arm in maximum abduction position. Using the FibroScan (Echosens, Paris, France) guide, a portion of liver of at least 60 mm in thickness, free of large vessels, was identified for examination. The rate of successful measurement was calculated as the ratio between the numbers of validated to total measurements. The results were expressed as a median value of the total measurements in kilo Pascal (kPa). TE was considered reliable when the following criteria had been met:

  • Ten successful measurements.

  • An interquartile range (IQR) lower than 30% of the median value.

  • A success rate of more than 60%.23

Liver stiffness was considered as the median of all valid measurements.

Liver fibrosis staging

Liver fibrosis, estimated by TE, was converted to the METAVIR scoring system24 as proposed by Ziol, et al.:8 < 8.8 as F0-F1; 8.8-9.6 as F2; > 9.6-14.6 as F3 and > 14.6 kPa as F4.

Liver biopsy

Liver biopsy specimens were obtained under complete aseptic procedures to retrieve 15 mm core or at least 15 portal tracts. The specimen was processed and stained with hematoxline and eosine. Fibrosis was staged on a 0.4 scale:

  • F0: no fibrosis.

  • F1: portal fibrosis without septa.

  • F2: portal fibrosis and few septa.

  • F3: numerous septa without cirrhosis.

  • F4: cirrhosis according to METAVIR scoring system.24

BMI measurement

Height and weight were measured by trained personnel. Height was rounded to the nearest 0.1 cm. Weight was measured using a digital scale, recorded to the nearest 0.1 kg. All measurements were taken at least twice; a third measurement was taken if the two measurements differed by a pre-determined amount (> 0.5 cm for height, > 0.2 kg for weight). The average of the two closest measurements was used. BMI was computed as the ratio of measured or reported weight [kg] to height [m] squared.

Statistical analysis

Statistical analyses were performed using version 24, SPSS (Statistical Package for Social Sciences) (IBM Corp., USA). Continuous variables were reported as median (IQR). Categorical variables were reported as frequency (%). Non-parametric tests, Mann-Whitney test for quantitative and Fisher’s exact test for qualitative comparisons, were used. Applicable examinations obtained by both operators were compared and assessed by Wilcoxon signed-rank for paired continuous variables, Mann-Whitney U test, and Spearman’s rank correlation. Inter-observer agreement was assessed the intra class correlation coefficient (ICC) and Kappa (κ) index. In addition, the Bland-Altman graphic was plotted.25 Significance level was determined when P ≤ 0.05 assuming two tailed tests.

Results

TE was performed by both operators in 356 patients [70.8% male gender, median (IQR) age 39 (31–47) years, BMI 27.6 (24.4–32.5) kg/m2]. Table 1 shows the baseline characteristics of the studied patients.

Table 1.

Baseline characteristics of studied patients.

Characteristic  Value 
All patients  356 
Male Gender  252 (70.8%) 
Age (years)  39.00 (31.00-47.00) 
BMI (kg/m227.57 (24.44–32.51) 
BMI ≥ 30 kg/m2  111 (31.2%) 
ALT (U/L)  47.50 (32.00–69.75) 
AST (U/L)  38.00 (28.93–60.00) 
S. albumin (g/dL)  4.50 (4.20-4.80) 
S. bilirubin(mg/dL)  0.70 (0.60–0.80) 
Glucose (mg/dL)  91.00 (84.75-102.00) 
Hgb (g/dL)  14.00 (12.90-15.10) 
WBCs(/cmm36.3 (5.2-7.5) 
Platelets (/cmm3207 (167-242) 
HCV PCR (IU/L)  643500 (154500-1468312) 

Data are presented as number (%), or median (IQR). BMI: body mass index. ALT: alanine transaminase. AST: aspartate transaminase. Hgb: hemoglobin. WBCs: white blood cells. HCV PCR: hepatitis C virus polymerase chain reaction.

The use of receiver operator characteristic (ROC) curves to get cut-off points for this data and the relation of these classifications to liver biopsy Metavir score were previously reported in a separate paper.26

The overall inter observer agreement ICC was 0.921 (95% CI 0.903-0.936). The correlation between first and second operator was excellent (Spearman’s value q = 0.808, p < 0.001). Figure 1 graphically displays the relationship between the results of both tests. However, we observed an important difference of the median values of LSM between examinations performed by the first and second operator in the paired patients (6.8 kPa for the first operator vs. 7.6 kPa for the second operator; p = 0.002).

Figure 1.

Correlation between the two liver stiffness measurements.

(0.1MB).

Table 2 shows number of patient staged for liver fibrosis by FibroScan performed by both operators based on the score system proposed by Ziol, et al. 2005.8 Inter-observer reliability values were κ = 0.557 (p < 0.001). A not negligible discordance of fibrosis staging between operators was observed by this method (87 cases, 24.4%). Discordance of at least one stage and for two or more stages of fibrosis occurred in 60 cases (16.9%) and 27 cases (7.6%) respectively.

Table 2.

Patient (n) staged for liver fibrosis by FibroScan performed by both operators based on the score system proposed by Ziol, et al. 2005.8

First operator  Second operator
  F0-1  F2  F3  F4  Total 
F0-1  198  18  18  234 
F2  10  27 
F3  27  10  54 
F4  36  41 
Total  217  34  59  46  356 

κ = 0.557, p < 0.001.

Table 3 summarizes the factors associated with discordance on fibrosis stage based on FibroScan. It appears that obesity (BMI ≥ 30 kg/m2) is the main factor associated with discordance (p = 0.002).

Table 3.

Risk factors associated with concordance/discordance on fibrosis staging based TE between the two operators.

Characteristic  Concordance of fibrosis stage  Discordance of at least one fibrosis stage  P value 
Number  269 (75.6%)  87 (24.4%)   
Male Gender  186 (69.1%)  66 (75.9%)  0.278 
Age, years  38.00 (29.00-46.00)  42.00 (33.00-49.00)  0.048 
BMI, kg/m2  27.46 (24.43-30.40)  28.80 (24.58-31.13)  0.170 
BMI ≥ 30 kg/m2  72 (26.8%)  39 (44.8%)  0.002 
ALT, U/L  47.00 (31.00-73.00)  48.00 (34.00-66.00)  0.973 
AST, U/L  38.00 (28.45-62.50)  37.00 (29.00-51.00)  0.293 
Albumin  4.50 (4.20-4.80)  4.50 (4.30-4.70)  0.686 
Bilirubin  0.70 (0.60-0.87)  0.80 (0.70-0.90)  0.225 
Glucose  91.00 (85.00-100.00)  89.50 (84.00-106.25)  0.788 
Hgb  14.00 (12.90-15.10)  14.00 (13.10-15.10)  0.610 
WBCs  6300 (5105-7500)  6500 (5410-7600)  0.245 
Platelets  210.00 (169.00-244.50)  196.00 (165.00-233.00)  0.465 
HCV PCR  590000 (156000-1230000)  690192 (140000-2860000)  0.143 

Data are presented as number (%), or median (IQR). BMI: body mass index. ALT: alanine transaminase. AST: aspartate transaminase. Hgb: hemoglobin. WBCs: white blood cells. HCV PCR: hepatitis C virus polymerase chain reaction.

Bland-Altman plot showed an acceptable agreement, presenting only thirteen patients scoring outside the tramlines (95 percent limits of agreement of ± 2 standard deviations) (Figure 2). However, this graphic highlighted a trend of difference across the mean rates with a greater disagreement in higher liver stiffness.

Figure 2.

Bland and Altman plot. The solid line represents the mean of the difference of LSM performed by both operators. The dashed lines define the limit of agreement (mean of LSM ± 2SD).

(0.11MB).
Discussion

In the last years, papers were published referring to the variability in TE, most of them presenting conflicting results.11,2730 Although this study has shown an excellent correlation between the two operators, we should highlight a considerable inter observer variability in TE. The excellent correlation between operators [ICC 0.921 (95% CI 0.903-0.936); p < 0.001 and Sperman’s q = 0.808; p < 0.001] described in our study confirmed the results of previous publications.11,27,29 Furthermore, the κ value for diagnosis of fibrosis stages showed in our results, was very similar to those described by others authors.28,30 Fraquelli, et al.,11 the first authors that evaluated the reproducibility of TE, reported an excellent inter observer ICC of 0.98 (0.977–0.987) in 200 patients with chronic liver disease, most of them with CHC infection. Boursier, et al.27 showed 25% of discordance of at least one stage of fibrosis. This relative high discrepancy of fibrosis stage was also reported by Roca, et al.29 in a more recent publication (23%). We found similar rates of discordance (24.4%) with those described by these previous authors27,29 and smaller rates than those found by Perazzo, et al.30 who found rate of discordance of 35%. TE might be influenced by the etiology of liver disease31 and the prevalence of fibrosis, known as spectrum effect.32 These two major factors may explain the difference between these studies. Our study included exclusively mono-infected CHC patients. Similarly, study of Perazzo, et al.30 included only CHC mono-infected patients. Conversely, Fraquelli, et al.11 and Boursier, et al27 included patients with chronic liver disease of mixed etiologies and Roca, et al.29 enrolled HIV patients, most of them (61%) with hepatitis C co infection and mild liver fibrosis.

These high rates of discrepancy of at least one stage of fibrosis are not negligible and might influence the management of patients with CHC. Distinction between mild and fibrosis F ≥ 2 indicates antiviral treatment in many countries or may have impact on the duration of treatment. In this present study 55 (15.4%) patients were classified as mild fibrosis by one operator and F ≥ 2 by the other. Furthermore, the diagnosis of cirrhosis defines the start of hepatocellular carcinoma screening in many countries. Our study reported discordance in 15 (4.2%) patients on the cirrhosis diagnosis between operators impacting in the hepatocellular screening. Thus, about 20% of our patients would have had impact on their management by this discordance when using exclusively TE.

In a study that evaluated more than 13,000 TE examinations, unreliable results were independently associated with body mass index, lower operator experience, older age, female gender, and metabolic factors.15 However, in our study, only overweight (BMI ≥ 30 kg/m2) was significantly associated with concordance/discordance on fibrosis staging based on TE between the two operators. TE should be used cautiously as an indicator of liver biopsy for assessing liver fibrosis in patients with fat problems. An association of inter observer discrepancy with higher body mass index has been found in other studies like that of Fraquelli, et al.,11 Boursier, et al.,21 and Wong, et al.34 The interaction of fat with low-frequency vibrations of TE may affect the signal to noise ratio, which is the relevant parameter for assessing liver stiffness.11

Our study major strength was the fact that our sample was composed exclusively of patients with CHC infection. Previous studies that have evaluated TE inter observer variability analyzed patients with chronic liver disease of mixed etiologies, with the exception of Perazzo, et al.30 LSM accuracy and proposed cutoffs were different according to the liver disorder.33 Probably, also there is a variation in the inter observer agreement of this method in different hepatic diseases.

The inter observer variability might be caused by interpretation of artificial TE cutoffs. In our study, LSM were well correlated between operators. Among 51 patients diagnosed as cirrhosis (F4) by at least one operator, none were misclassified as mild fibrosis (F0F1). The major discrepancy was observed in F0 to F2 fibrosis stages, where published cut-offs are extremely variable.

Non-invasive biomarkers can also accurately stage liver fibrosis in CHC.35 The association of biomarkers with TE would minimize the limitations of TE and could be useful in clinical practice.

Thus, clinicians should be aware that the inter observer variability in TE might exist and could impact on management of patients with CHC. TE results should be carefully analyzed by expert hands, especially in patients with a single evaluation caused by the possibility of inter observer variability.

Conclusion

Although LSM has had an excellent correlation between the two operators, TE presented an inter-observer variability that may not be negligible. TE is a user-friendly non-invasive technique, however, its performance may be altered by high BMI, which affects both the feasibility and reproducibility of the test. It is recommended that with high BMI, two TE examinations with the XL probe, with two experienced examiners, should be done. The presence of this inter observer variability should be taken in consideration during the use of TE in treatment centers, research, and clinical trials.

Abbreviations

  • ALT: alanine transaminase.

  • AST: aspartate transaminase.

  • BMI: body mass index.

  • CHC: chronic hepatitis C.

  • HCV: hepatitis C virus.

  • Hgb: hemoglobin.

  • ICC: intra class correlation.

  • IQR: inter quartile range.

  • kPa: kilo Pascal.

  • LSM: liver stiffness measurement.

  • PCR: polymerase chain reaction.

  • ROC: receiver operator curve.

  • SD: standard deviation.

  • SPSS: statistical package for social sciences.

  • TE: transient elastography.

  • WBCs: white blood cells.

Conflict of Interest

The authors who have taken part in this study declared that they do not have anything to disclose regarding conflict of interest with respect to this manuscript.

Financial Support

This work was funded by Science Technology Developmental Fund (STDF) grant, Egyptian Ministry of higher education and scientific researh under call named; TC/2/Health/2010/hep-1.6:diagnostic imaging for accurate diagnosis and staging of the disease, project number 3512.

References
[1.]
Bravo A.A., Sheth S.G., Chopra S..
Liver biopsy.
N Engl J Med, 344 (2001), pp. 495-500
[2.]
Saadeh S., Cammell G., Carey W.D., Younossi Z., Barnes D., Easley K..
The role of liver biopsy in chronic hepatitis C.
Hepatology, 33 (2001), pp. 196-200
[3.]
Piccinino F., Sagnelli E., Pasquale G., Giusti G..
Complications following percutaneous liver biopsy. A multicentre retrospective study on 68,276 biopsies.
J Hepatol, 2 (1986), pp. 165-173
[4.]
Bedossa P., Dargere D., Paradis V..
Sampling variability of liver fibrosis in chronic hepatitis C.
Hepatology, 38 (2003), pp. 1449-1457
[5.]
Guido M., Rugge M..
Liver biopsy sampling in chronic viral hepatitis.
Semin Liver Dis, 24 (2004), pp. 89-97
[6.]
Colloredo G., Guido M., Sonzogni A., Leandro G..
Impact of liver biopsy size on histological evaluation of chronic viral hepatitis: the smaller the sample, the milder the disease.
J Hepatol, 39 (2003), pp. 239-244
[7.]
Rousselet M.C., Michalak S., Dupre F., Croué A., Bedossa P., Saint-André J.P., Calès P..
Hepatitis Network 49. Sources of variability in histological scoring of chronic viral hepatitis.
Hepatology, 41 (2005), pp. 257-264
[8.]
Ziol M., Handra-Luca A., Kettaneh A., Christidis C., Mal F., Kazemi F., de Lédinghen V., et al.
Noninvasive assessment of liver fibrosis by measurement of stiffness in patients with chronic hepatitis C.
Hepatology, 41 (2005), pp. 48-54
[9.]
Castera L., Vergniol J., Foucher J., Le Bail B., Chanteloup E., Haaser M., Darriet M., et al.
Prospective comparison of transient elastography, Fibrotest, APRI, and liver biopsy for the assessment of fibrosis in chronic hepatitis C.
Gastroenterology, 128 (2005), pp. 343-350
[10.]
Ganne-Carrie N., Ziol M., de Le’dinghen V., Douvin C., Marcellin P., Castera L., Dhumeaux D., et al.
Accuracy of liver stiffness measurement for the diagnosis of cirrhosis in patients with chronic liver diseases.
Hepatology, 44 (2006), pp. 1511-1517
[11.]
Fraquelli M., Rigamonti C., Casazza G., Conte D., Donato M.F., Ronchi G., Colombo M..
Reproducibility of transient elastography in the evaluation of liver fibrosis in patients with chronic liver disease.
[12.]
Foucher J., Chanteloup E., Vergniol J., Castera L., Le Bail B., Adhoute X., Bertet J., et al.
Diagnosis of cirrhosis by transient elastography (FibroScan): a prospective study.
Gut, 55 (2006), pp. 403-408
[13.]
World Health Organization. Obesity and overweight: Fact Sheet. http://www.who.int/mediacentre/factsheets/fs311/ en/Accessed 4 October 2017.
[14.]
Carrión J.A., Puigvehí M., Coll S., Garcia-Retortillo M., Cañete N., Fernández R., Márquez C., et al.
Applicability and accuracy improvement of transient elastography using the M and XL probes by experienced operators.
J Viral Hepat, 22 (2015), pp. 297-306
[15.]
Castera L., Foucher J., Bernard P.H., Carvalho F., Allaix D., Merrouche W., Couzigou P., et al.
Pitfalls of liver stiffness measurement: a 5-year prospective study of 13,369 examinations.
Hepatology, 51 (2010), pp. 828-835
[16.]
Ferraioli G., Filice C., Castera L., Choi B.I., Sporea I., Wilson S.R., Cosgrove D., et al.
WFUMB guidelines and recommendations for clinical use of ultrasound elastography: Part 3: liver.
Ultrasound Med Biol, 41 (2015), pp. 1161-1179
[17.]
Puigvehí M., Broquetas T., Coll S., Garcia-Retortillo M., Cañete N., Fernández R., Gimeno J., et al.
Impact of anthropometric features on the applicability and accuracy of FibroScan® (M and XL) in overweight/obese patients.
J Gastroenterol Hepatol, 32 (2017), pp. 1746-1753
[18.]
Deuffic-Burban S., Mohamed S.K., Larouze B., Carrat F., Valleron A.J..
Expected increase in hepatitis C related mortality in Egypt due to pre-2000 infections.
J Hepatol, 44 (2006), pp. 455-461
[19.]
Breban R., Doss W., Esmat G., Elsayed M., Hellard M., Ayscue P., Albert M., et al.
Towards realistic estimates of HCV incidence in Egypt.
J Viral Hepat, 20 (2013), pp. 294-296
[20.]
Ministry of Health and Population, Egypt. Plan of Action for the Prevention, Care and Treatment of Viral Hepatitis, Egypt 2014-2018.
[21.]
Gaia S., Carenzi S., Barilli A.L., Bugianesi E., Smedile A., Brunello F., Marzano A., et al.
Reliability of transient elastography for the detection of fibrosis in nonalcoholic fatty liver disease and chronic viral hepatitis.
J Hepatol, 54 (2011), pp. 64-71
[22.]
Tsochatzis E.A., Gurusamy K.S., Ntaoula S., Cholongitas E., Davidson B.R., Burroughs A.K..
Elastography for the diagnosis of severity of fibrosis in chronic liver disease: a meta-analysis of diagnostic accuracy.
J Hepatol, 54 (2011), pp. 650-659
[23.]
Poynard T., Ingiliz P., Elkrief L., Munteanu M., Lebray P., Morra R., Messous D., et al.
Concordance in a world without a gold standard: a new non-invasive methodology for improving accuracy of fibrosis markers.
[24.]
Bedossa P..
Intraobserver and interobserver variations in liver biopsy interpretation in patients with chronic hepatitis C. The French METAVIR Cooperative Study Group.
Hepatology, 20 (1994), pp. 15-20
[25.]
Bland J.M., Altman D.G..
Statistical methods for assessing agreement between two methods of clinical measurement.
[26.]
Shiha G., El-Etreby S., Bahgat M., Hamed M., El Sherbini M., Ghoneem E.A., Zalata K., et al.
Comparison between Transient Elastography (FibroScan) and Liver Biopsy for the Diagnosis of Hepatic Fibrosis in Chronic Hepatitis C Patients.
MJVH, 2 (2016), pp. 17-25
[27.]
Boursier J., Konate A., Gorea G., Reaud S., Quemener E., Oberti F., Hubert-Fouchard I., et al.
Reproducibility of liver stiffness measurement by ultrasonographic elastometry.
Clin Gastroenterol Hepatol, 6 (2008), pp. 1263-1269
[28.]
Neukam K., Recio E., Camacho A., Macías J., Rivero A., Mira J.A., López C., et al.
Interobserver concordance in the assessment of liver fibrosis in HIV/HCV-coinfected patients using transient elastometry.
Eur J Gastroenterol Hepatol, 22 (2010), pp. 801-807
[29.]
Roca B., Resino E., Torres V., Herrero E., Penades M..
Interobserver discrepancy in liver fibrosis using transient elastography.
J Viral Hepat, 19 (2012), pp. 711-715
[30.]
Perazzo H., Fernandes F.F., Gomes A., Terra C., Perez R.M., Figueiredo F.A..
Interobserver variability in transient elastography analysis of patients with chronic hepatitis C.
Liver Int, 35 (2015), pp. 1533-1539
[31.]
Sebastiani G., Castera L., Halfon P., Pol S., Mangia A., Di Marco V., Pirisi M., et al.
The impact of liver disease aetiology and the stages of hepatic fibrosis on the performance of non-invasive fibrosis biomarkers: an international study of 2411 cases.
Aliment Pharmacol Ther, 34 (2011), pp. 1202-1216
[32.]
Poynard T., De Ledinghen V., Zarski J.P., Stanciu C., Munteanu M., Vergniol J., France J., et al.
FibroTest and Fibroscan performances revisited in patients with chronic hepatitis C. Impact of the spectrum effect and the applicability rate.
Clin Res Hepatol Gastroenterol, 35 (2011), pp. 720-730
[33.]
De Ledinghen V., Vergniol J..
Transient elastography (FibroScan).
Gastroenterol Clin Biol, 32 (2008), pp. 58-67
[34.]
Wong G.L., Wong V.W., Chim A.M., Yiu K.K., Chu S.H., Li M.K., Chan H.L..
Factors associated with unreliable liver stiffness measurement and its failure with transient elastography in the Chinese population.
J Gastroenterol Hepatol, 26 (2011), pp. 300-305
[35.]
Chou R., Wasson N..
Blood tests to diagnose fibrosis or cirrhosis in patients with chronic hepatitis C virus infection: a systematic review.
Copyright © 2018. Fundación Clínica Médica Sur, A.C.
Descargar PDF
Opciones de artículo
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos