Artículo
Comprando el artículo el PDF del mismo podrá ser descargado
Precio 19,34 €
Comprar ahora
array:25 [ "pii" => "S0365669117300163" "issn" => "03656691" "doi" => "10.1016/j.oftal.2016.11.020" "estado" => "S300" "fechaPublicacion" => "2017-09-01" "aid" => "1141" "copyright" => "Sociedad Española de Oftalmología" "copyrightAnyo" => "2017" "documento" => "simple-article" "crossmark" => 1 "subdocumento" => "cor" "cita" => "Arch Soc Esp Oftalmol. 2017;92:e53-4" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:2 [ "total" => 24 "formatos" => array:2 [ "HTML" => 20 "PDF" => 4 ] ] "Traduccion" => array:1 [ "en" => array:19 [ "pii" => "S2173579417300403" "issn" => "21735794" "doi" => "10.1016/j.oftale.2016.11.012" "estado" => "S300" "fechaPublicacion" => "2017-09-01" "aid" => "1141" "copyright" => "Sociedad Española de Oftalmología" "documento" => "simple-article" "crossmark" => 1 "subdocumento" => "cor" "cita" => "Arch Soc Esp Oftalmol. 2017;92:e53-4" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:2 [ "total" => 2 "formatos" => array:2 [ "HTML" => 1 "PDF" => 1 ] ] "en" => array:10 [ "idiomaDefecto" => true "cabecera" => "<span class="elsevierStyleTextfn">Letter to the Editor</span>" "titulo" => "Endothelial loss with AcrySof<span class="elsevierStyleSup">®</span> Cachet<span class="elsevierStyleSup">®</span> angle-supported phakic lens" "tienePdf" => "en" "tieneTextoCompleto" => "en" "paginas" => array:1 [ 0 => array:2 [ "paginaInicial" => "e53" "paginaFinal" => "e54" ] ] "titulosAlternativos" => array:1 [ "es" => array:1 [ "titulo" => "Pérdida endotelial con la lente fáquica de apoyo angular AcrySof<span class="elsevierStyleSup">®</span> Cachet<span class="elsevierStyleSup">®</span>" ] ] "contieneTextoCompleto" => array:1 [ "en" => true ] "contienePdf" => array:1 [ "en" => true ] "autores" => array:1 [ 0 => array:2 [ "autoresLista" => "V. Galvis, A. Tello, N.I. Carreño, R.D. Berrospi, C.A. Niño, M.O. Cuadros" "autores" => array:6 [ 0 => array:2 [ "nombre" => "V." "apellidos" => "Galvis" ] 1 => array:2 [ "nombre" => "A." "apellidos" => "Tello" ] 2 => array:2 [ "nombre" => "N.I." "apellidos" => "Carreño" ] 3 => array:2 [ "nombre" => "R.D." "apellidos" => "Berrospi" ] 4 => array:2 [ "nombre" => "C.A." "apellidos" => "Niño" ] 5 => array:2 [ "nombre" => "M.O." "apellidos" => "Cuadros" ] ] ] ] ] "idiomaDefecto" => "en" "Traduccion" => array:1 [ "es" => array:9 [ "pii" => "S0365669117300163" "doi" => "10.1016/j.oftal.2016.11.020" "estado" => "S300" "subdocumento" => "" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:1 [ "total" => 0 ] "idiomaDefecto" => "es" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0365669117300163?idApp=UINPBA00004N" ] ] "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S2173579417300403?idApp=UINPBA00004N" "url" => "/21735794/0000009200000009/v2_201708291316/S2173579417300403/v2_201708291316/en/main.assets" ] ] "itemSiguiente" => array:19 [ "pii" => "S0365669117301235" "issn" => "03656691" "doi" => "10.1016/j.oftal.2017.02.014" "estado" => "S300" "fechaPublicacion" => "2017-09-01" "aid" => "1183" "copyright" => "Sociedad Española de Oftalmología" "documento" => "simple-article" "crossmark" => 1 "subdocumento" => "cor" "cita" => "Arch Soc Esp Oftalmol. 2017;92:e55" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:2 [ "total" => 29 "formatos" => array:2 [ "HTML" => 24 "PDF" => 5 ] ] "es" => array:10 [ "idiomaDefecto" => true "cabecera" => "<span class="elsevierStyleTextfn">Carta al Director</span>" "titulo" => "Respuesta a los autores" "tienePdf" => "es" "tieneTextoCompleto" => "es" "paginas" => array:1 [ 0 => array:1 [ "paginaInicial" => "e55" ] ] "titulosAlternativos" => array:1 [ "en" => array:1 [ "titulo" => "Author's reply" ] ] "contieneTextoCompleto" => array:1 [ "es" => true ] "contienePdf" => array:1 [ "es" => true ] "autores" => array:1 [ 0 => array:2 [ "autoresLista" => "J.L. Alio" "autores" => array:1 [ 0 => array:2 [ "nombre" => "J.L." "apellidos" => "Alio" ] ] ] ] ] "idiomaDefecto" => "es" "Traduccion" => array:1 [ "en" => array:9 [ "pii" => "S2173579417301160" "doi" => "10.1016/j.oftale.2017.02.017" "estado" => "S300" "subdocumento" => "" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:1 [ "total" => 0 ] "idiomaDefecto" => "en" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S2173579417301160?idApp=UINPBA00004N" ] ] "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0365669117301235?idApp=UINPBA00004N" "url" => "/03656691/0000009200000009/v1_201708280004/S0365669117301235/v1_201708280004/es/main.assets" ] "itemAnterior" => array:19 [ "pii" => "S0365669117300308" "issn" => "03656691" "doi" => "10.1016/j.oftal.2017.01.006" "estado" => "S300" "fechaPublicacion" => "2017-09-01" "aid" => "1155" "copyright" => "Sociedad Española de Oftalmología" "documento" => "article" "crossmark" => 1 "subdocumento" => "fla" "cita" => "Arch Soc Esp Oftalmol. 2017;92:451-4" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:2 [ "total" => 41 "formatos" => array:2 [ "HTML" => 31 "PDF" => 10 ] ] "es" => array:13 [ "idiomaDefecto" => true "cabecera" => "<span class="elsevierStyleTextfn">Comunicación corta</span>" "titulo" => "Infiltrados estériles tras <span class="elsevierStyleItalic">cross-linking</span>" "tienePdf" => "es" "tieneTextoCompleto" => "es" "tieneResumen" => array:2 [ 0 => "es" 1 => "en" ] "paginas" => array:1 [ 0 => array:2 [ "paginaInicial" => "451" "paginaFinal" => "454" ] ] "titulosAlternativos" => array:1 [ "en" => array:1 [ "titulo" => "Sterile infiltrates after cross-linking" ] ] "contieneResumen" => array:2 [ "es" => true "en" => true ] "contieneTextoCompleto" => array:1 [ "es" => true ] "contienePdf" => array:1 [ "es" => true ] "resumenGrafico" => array:2 [ "original" => 0 "multimedia" => array:7 [ "identificador" => "fig0020" "etiqueta" => "Figura 4" "tipo" => "MULTIMEDIAFIGURA" "mostrarFloat" => true "mostrarDisplay" => false "figura" => array:1 [ 0 => array:4 [ "imagen" => "gr4.jpeg" "Alto" => 628 "Ancho" => 1575 "Tamanyo" => 130630 ] ] "descripcion" => array:1 [ "es" => "<p id="spar0040" class="elsevierStyleSimplePara elsevierViewall">Resultado post-operatorio del paciente tras la queratoplastia penetrante. A) Fotografía de polo anterior. B) Hendidura.</p>" ] ] ] "autores" => array:1 [ 0 => array:2 [ "autoresLista" => "G. García de Oteyza, J. Álvarez de Toledo" "autores" => array:2 [ 0 => array:2 [ "nombre" => "G." "apellidos" => "García de Oteyza" ] 1 => array:2 [ "nombre" => "J." "apellidos" => "Álvarez de Toledo" ] ] ] ] ] "idiomaDefecto" => "es" "Traduccion" => array:1 [ "en" => array:9 [ "pii" => "S2173579417301299" "doi" => "10.1016/j.oftale.2017.06.002" "estado" => "S300" "subdocumento" => "" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:1 [ "total" => 0 ] "idiomaDefecto" => "en" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S2173579417301299?idApp=UINPBA00004N" ] ] "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0365669117300308?idApp=UINPBA00004N" "url" => "/03656691/0000009200000009/v1_201708280004/S0365669117300308/v1_201708280004/es/main.assets" ] "asociados" => array:1 [ 0 => array:19 [ "pii" => "S0365669117301235" "issn" => "03656691" "doi" => "10.1016/j.oftal.2017.02.014" "estado" => "S300" "fechaPublicacion" => "2017-09-01" "aid" => "1183" "copyright" => "Sociedad Española de Oftalmología" "documento" => "simple-article" "crossmark" => 1 "subdocumento" => "cor" "cita" => "Arch Soc Esp Oftalmol. 2017;92:e55" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:2 [ "total" => 29 "formatos" => array:2 [ "HTML" => 24 "PDF" => 5 ] ] "es" => array:10 [ "idiomaDefecto" => true "cabecera" => "<span class="elsevierStyleTextfn">Carta al Director</span>" "titulo" => "Respuesta a los autores" "tienePdf" => "es" "tieneTextoCompleto" => "es" "paginas" => array:1 [ 0 => array:1 [ "paginaInicial" => "e55" ] ] "titulosAlternativos" => array:1 [ "en" => array:1 [ "titulo" => "Author's reply" ] ] "contieneTextoCompleto" => array:1 [ "es" => true ] "contienePdf" => array:1 [ "es" => true ] "autores" => array:1 [ 0 => array:2 [ "autoresLista" => "J.L. Alio" "autores" => array:1 [ 0 => array:2 [ "nombre" => "J.L." "apellidos" => "Alio" ] ] ] ] ] "idiomaDefecto" => "es" "Traduccion" => array:1 [ "en" => array:9 [ "pii" => "S2173579417301160" "doi" => "10.1016/j.oftale.2017.02.017" "estado" => "S300" "subdocumento" => "" "abierto" => array:3 [ "ES" => false "ES2" => false "LATM" => false ] "gratuito" => false "lecturas" => array:1 [ "total" => 0 ] "idiomaDefecto" => "en" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S2173579417301160?idApp=UINPBA00004N" ] ] "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0365669117301235?idApp=UINPBA00004N" "url" => "/03656691/0000009200000009/v1_201708280004/S0365669117301235/v1_201708280004/es/main.assets" ] ] "es" => array:12 [ "idiomaDefecto" => true "cabecera" => "<span class="elsevierStyleTextfn">Carta al director</span>" "titulo" => "Pérdida endotelial con la lente fáquica de apoyo angular AcrySof<span class="elsevierStyleSup">®</span> Cachet<span class="elsevierStyleSup">®</span>" "tieneTextoCompleto" => true "saludo" => "<span class="elsevierStyleItalic">Sr. Director:</span>" "paginas" => array:1 [ 0 => array:2 [ "paginaInicial" => "e53" "paginaFinal" => "e54" ] ] "autores" => array:1 [ 0 => array:4 [ "autoresLista" => "V. Galvis, A. Tello, N.I. Carreño, R.D. Berrospi, C.A. Niño, M.O. Cuadros" "autores" => array:6 [ 0 => array:3 [ "nombre" => "V." "apellidos" => "Galvis" "referencia" => array:3 [ 0 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">a</span>" "identificador" => "aff0005" ] 1 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">b</span>" "identificador" => "aff0010" ] 2 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">c</span>" "identificador" => "aff0015" ] ] ] 1 => array:4 [ "nombre" => "A." "apellidos" => "Tello" "email" => array:1 [ 0 => "alejandrotello@gmail.com" ] "referencia" => array:4 [ 0 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">a</span>" "identificador" => "aff0005" ] 1 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">b</span>" "identificador" => "aff0010" ] 2 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">c</span>" "identificador" => "aff0015" ] 3 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">*</span>" "identificador" => "cor0005" ] ] ] 2 => array:3 [ "nombre" => "N.I." "apellidos" => "Carreño" "referencia" => array:3 [ 0 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">a</span>" "identificador" => "aff0005" ] 1 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">b</span>" "identificador" => "aff0010" ] 2 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">c</span>" "identificador" => "aff0015" ] ] ] 3 => array:3 [ "nombre" => "R.D." "apellidos" => "Berrospi" "referencia" => array:2 [ 0 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">a</span>" "identificador" => "aff0005" ] 1 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">b</span>" "identificador" => "aff0010" ] ] ] 4 => array:3 [ "nombre" => "C.A." "apellidos" => "Niño" "referencia" => array:2 [ 0 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">a</span>" "identificador" => "aff0005" ] 1 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">b</span>" "identificador" => "aff0010" ] ] ] 5 => array:3 [ "nombre" => "M.O." "apellidos" => "Cuadros" "referencia" => array:2 [ 0 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">a</span>" "identificador" => "aff0005" ] 1 => array:2 [ "etiqueta" => "<span class="elsevierStyleSup">b</span>" "identificador" => "aff0010" ] ] ] ] "afiliaciones" => array:3 [ 0 => array:3 [ "entidad" => "Centro Oftalmológico Virgilio Galvis, Floridablanca, Colombia" "etiqueta" => "a" "identificador" => "aff0005" ] 1 => array:3 [ "entidad" => "Fundación Oftalmológica de Santander FOSCAL, Floridablanca, Colombia" "etiqueta" => "b" "identificador" => "aff0010" ] 2 => array:3 [ "entidad" => "Universidad Autónoma de Bucaramanga, Facultad de Salud, Bucaramanga, Colombia" "etiqueta" => "c" "identificador" => "aff0015" ] ] "correspondencia" => array:1 [ 0 => array:3 [ "identificador" => "cor0005" "etiqueta" => "⁎" "correspondencia" => "<span class="elsevierStyleItalic">Autor para correspondencia</span>." ] ] ] ] "titulosAlternativos" => array:1 [ "en" => array:1 [ "titulo" => "Endothelial loss with AcrySof<span class="elsevierStyleSup">®</span> Cachet<span class="elsevierStyleSup">®</span> angle-supported phakic lens" ] ] "textoCompleto" => "<span class="elsevierStyleSections"><p id="par0005" class="elsevierStylePara elsevierViewall">Leímos con interés el artículo sobre los resultados con la lente fáquica AcrySof<span class="elsevierStyleSup">®</span> Cachet<span class="elsevierStyleSup">®</span> por Alió et al.<a class="elsevierStyleCrossRef" href="#bib0020"><span class="elsevierStyleSup">1</span></a>. Nuestro primer comentario es que, aunque en las figuras y tablas se menciona, hubiese sido preferible para claridad de los lectores que se indicara expresamente en el texto que solo 25 ojos tuvieron un seguimiento a 5 años.</p><p id="par0010" class="elsevierStylePara elsevierViewall">Desde finales de la década de 1980 Baikoff revivió el concepto de las lentes intraoculares fáquicas de apoyo angular con los modelos Baikoff (ZB, ZB5M y NuVita). Adicionalmente, diversos fabricantes produjeron en la primera década del siglo 21 otros tipos de lentes similares (Phakic 6 H2, Vivarte, GBR, NewLife, I-Care, ZSAL-4 y AcrySof<span class="elsevierStyleSup">®</span> Cachet<span class="elsevierStyleSup">®</span>). Sin embargo, en la actualidad, sin excepción, todas las lentes fáquicas de apoyo angular han sido retiradas del mercado por complicaciones a medio y largo plazo, sobre todo relacionadas con la pérdida endotelial (incluyendo el modelo AcrySof<span class="elsevierStyleSup">®</span> Cachet<span class="elsevierStyleSup">®</span> de Alcon<span class="elsevierStyleSup">®</span> retirado en septiembre de 2014). La explicación dada por Alcon<span class="elsevierStyleSup">®</span>, en su carta a los oftalmólogos, fue que tomaron la decisión por que el 2,7% de las lentes de un grupo de 1.323 casos debió ser explantado por pérdida endotelial<a class="elsevierStyleCrossRef" href="#bib0025"><span class="elsevierStyleSup">2</span></a>.</p><p id="par0015" class="elsevierStylePara elsevierViewall">La literatura es muy escasa sobre explantes de esta lente. Pechméja et al. reportaron el caso de un paciente que requirió explantación por presentar pérdida endotelial severa. El conteo endotelial fue encontrado en 680 células/mm<span class="elsevierStyleSup">2</span> antes del explante<a class="elsevierStyleCrossRef" href="#bib0030"><span class="elsevierStyleSup">3</span></a>. Alió et al. también mencionan que en uno de los ojos debieron retirar la lente AcrySof<span class="elsevierStyleSup">®</span> Cachet<span class="elsevierStyleSup">®</span>. Sería importante conocer la densidad de células endoteliales de ese caso, antes y después del explante. Adicionalmente mencionan que un ojo tuvo densidades celulares menores a 1.500 células/mm<span class="elsevierStyleSup">2</span> (caso que explica el rango inferior tan bajo de la densidad celular a 5 años, 808 células/mm<span class="elsevierStyleSup">2</span>) ¿Se trató del caso ya referido de la explantación, o de otro ojo? Si fue otro paciente, ¿qué conducta se tomó? Sería interesante conocer cuántos de los 25 ojos seguidos a 5 años presentaron densidades entre 1.500 y 2.000 células/mm<span class="elsevierStyleSup">2</span>.</p><p id="par0020" class="elsevierStylePara elsevierViewall">Ahora, aunque los autores indican que la mayor pérdida endotelial ocurrió en los primeros 6 meses luego de cirugía, llama la atención que el rango inferior de esa medición se disminuyó de manera notoria luego de los 2 años de seguimiento, sugiriendo una pérdida continuada tardía, al menos en un ojo.</p><p id="par0025" class="elsevierStylePara elsevierViewall">El hecho que tantos intentos de desarrollar una lente fáquica de apoyo angular que sea segura, hayan fallado, y la presencia de complicaciones corneales serias que ponen en riesgo la visión de los pacientes, es sin duda un indicador muy sugestivo de que este tipo de abordaje no debe ser utilizado en el futuro. Por otra parte es muy importante que a los pacientes que se les implantó en el pasado estas lentes se les llame para realizarles un recuento de células endoteliales corneales, con el fin de evaluar la necesidad de un explante temprano, antes de que se presente edema corneal irreversible y la necesidad de trasplante de córnea.</p></span>" "pdfFichero" => "main.pdf" "tienePdf" => true "bibliografia" => array:2 [ "titulo" => "Bibliografía" "seccion" => array:1 [ 0 => array:2 [ "identificador" => "bibs0005" "bibliografiaReferencia" => array:3 [ 0 => array:3 [ "identificador" => "bib0020" "etiqueta" => "1" "referencia" => array:1 [ 0 => array:3 [ "comentario" => "[Article in English, Spanish]" "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "An angle-supported foldable phakic intraocular lens for correction of myopia: A five-year follow-up" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:5 [ 0 => "J.L. Alió" 1 => "A.B. Plaza-Puche" 2 => "F. Cavas" 3 => "P. Yébana Rubio" 4 => "E. Sala" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1016/j.oftal.2016.05.009" "Revista" => array:6 [ "tituloSerie" => "Arch Soc Esp Oftalmol." "fecha" => "2017" "volumen" => "92" "paginaInicial" => "4" "paginaFinal" => "11" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/27453580" "web" => "Medline" ] ] ] ] ] ] ] ] 1 => array:3 [ "identificador" => "bib0025" "etiqueta" => "2" "referencia" => array:1 [ 0 => array:1 [ "referenciaCompleta" => "Corrective Action Alcon AcrySof<span class="elsevierStyleSup">®</span> CACHET<span class="elsevierStyleSup">®</span> Phakic Lens Product Discontinuation. [consultado 27 Nov 2016] Disponible en: <a href="http://www.bfarm.de/SharedDocs/Kundeninfos/EN/11/2014/06204_14_Kundeninfo_en.pdf?__blob=publicationFile%26v=3">http://www.bfarm.de/SharedDocs/Kundeninfos/EN/11/2014/06204_14_Kundeninfo_en.pdf?__blob=publicationFile&v=3</a>." ] ] ] 2 => array:3 [ "identificador" => "bib0030" "etiqueta" => "3" "referencia" => array:1 [ 0 => array:2 [ "contribucion" => array:1 [ 0 => array:2 [ "titulo" => "Severe endothelial cell loss with anterior chamber phakic intraocular lenses" "autores" => array:1 [ 0 => array:2 [ "etal" => false "autores" => array:4 [ 0 => "J. Pechméja" 1 => "J. Guinguet" 2 => "J. Colin" 3 => "P.S. Binder" ] ] ] ] ] "host" => array:1 [ 0 => array:2 [ "doi" => "10.1016/j.jcrs.2012.04.022" "Revista" => array:6 [ "tituloSerie" => "J Cataract Refract Surg" "fecha" => "2012" "volumen" => "38" "paginaInicial" => "1288" "paginaFinal" => "1292" "link" => array:1 [ 0 => array:2 [ "url" => "https://www.ncbi.nlm.nih.gov/pubmed/22727299" "web" => "Medline" ] ] ] ] ] ] ] ] ] ] ] ] ] "idiomaDefecto" => "es" "url" => "/03656691/0000009200000009/v1_201708280004/S0365669117300163/v1_201708280004/es/main.assets" "Apartado" => array:4 [ "identificador" => "7280" "tipo" => "SECCION" "es" => array:2 [ "titulo" => "Cartas al director" "idiomaDefecto" => true ] "idiomaDefecto" => "es" ] "PDF" => "https://static.elsevier.es/multimedia/03656691/0000009200000009/v1_201708280004/S0365669117300163/v1_201708280004/es/main.pdf?idApp=UINPBA00004N&text.app=https://www.elsevier.es/" "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0365669117300163?idApp=UINPBA00004N" ]
Consulte los artículos y contenidos publicados en este medio, además de los e-sumarios de las revistas científicas en el mismo momento de publicación
Esté informado en todo momento gracias a las alertas y novedades
Acceda a promociones exclusivas en suscripciones, lanzamientos y cursos acreditados
Archivos de la Sociedad Española de Oftalmología es la revista oficial de la Sociedad que cuenta con más de 4000 socios. Publica de forma prioritaria trabajos de investigación básica, traslacional y clínica, como revisiones, artículos originales, comunicaciones cortas, editoriales, cartas al director y guías de práctica clínica relacionadas con la Oftalmología en sus diferentes subespecialidades. Se reserva una pequeña parte de las publicaciones para las comunicaciones más destacadas del Congreso anual de la Sociedad. Todos los manuscritos que se consideran para posible publicación son sometidos a una revisión por pares de evaluadores expertos (doble ciego). Publica un número cada mes y aunque el idioma oficial es el español todos los artículos son traducidos al idioma inglés para facilitar una mayor difusión de la información científica. Actualmente es la única revista de Oftalmología de habla hispana indexada en PubMed/MEDLINE, además de otras bases de datos internacionales prestigiosas, como Scopus.
PubMed/MedLine, Scopus, EMBASE, IBECS, IME, SCIELO, BIOSIS, SENIOR, COMPLUDOC
Ver másSJR es una prestigiosa métrica basada en la idea de que todas las citaciones no son iguales. SJR usa un algoritmo similar al page rank de Google; es una medida cuantitativa y cualitativa al impacto de una publicación.
Ver másSNIP permite comparar el impacto de revistas de diferentes campos temáticos, corrigiendo las diferencias en la probabilidad de ser citado que existe entre revistas de distintas materias.
Ver más¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?
Are you a health professional able to prescribe or dispense drugs?
Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos