Mínimo flujo de oxígeno necesario para soporte vital durante la simulación de reanimación post parada cardiorrespiratoria
Minimum oxygen flow needed for vital support during simulated post-cardiorespiratory arrest resuscitation
Visitas
1250
E. Sanz-Sanjoséa,
Autor para correspondencia
e.sanz.sanjose@gmail.com

Autor para correspondencia.
, J.J. Ariño Irujob, C.E. Sánchez Martína, C. González Perrinoa, F. López-Timonedaa
a Servicio de Anestesiología y Reanimación, Hospital Clínico San Carlos, Madrid, España
b Servicio de Anestesiología y Reanimación, Al Noor Hospital, Khalifa Branch, Abu Dabi, Emiratos Árabes Unidos
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (2)
Tablas (1)
Tabla 1. Límite inferior del intervalo de confianza de la media de FiO2 (%) obtenida empleando 4 flujos de oxígeno diferentes y 4 resucitadores distintos
Resumen

De acuerdo con las guías de la AHA y la ERC, la FiO2 a administrarse debería ser aquella con la que se obtuviera una SatO294%. El objetivo de este estudio es determinar el mínimo flujo de oxígeno y tiempo necesarios para alcanzar una FiO2 de 0,32 y de 0,80 durante el manejo posparada cardiaca. Se emplearon diferentes reanimadores, que fueron conectados a un pulmón artificial: Mark IV, SPUR II, Revivator Res-Q, O-TWO. Los flujos de oxígeno probados fueron 2, 5, 10 y 15lpm. Los test estadísticos aplicados fueron Bonferroni y U de Mann-Whitney. Se obtuvo una FiO20,32 con cualquiera de los flujos de oxígeno y reanimadores. Tras un mínimo de 75s ventilando con 2 o 5lpm, solo se consiguió una FiO2 de 0,80 con Mark IV. Se hallaron diferencias clínica y estadísticamente significativas (p<0,05): con 15lpm se necesitaron 35s para alcanzar una FiO20,80 con Mark IV (85,6 [0,3]) y Revivator (84,3 [1,5]) comparado con los 50s que precisó SPUR II (87,1 [6,4]); con 2lpm, todos los resucitadores alcanzaron una FiO20,32 en 30s(Mark IV (34,8 [1,3]), Revivator (35,7 [1,5]) y SPUR II (34,4 [2,1]), excepto O-TWO, que necesitó 35s (36,3 [4,3]). Para alcanzar una FiO2 de 0,32 se podría emplear cualquiera de los resucitadores usando 2lpm, aunque quizá el menos recomendable sería O-TWO. Si el objetivo fuera una FiO2 de 0,80, debería bastar con 10lpm, usando preferiblemente Mark IV o Revivator Res-Q. En conclusión, atendiendo a los resultados de nuestro estudio, ante cualquier situación potencial, sería preferible emplear Revivator Res-Q o Mark IV que O-TWO o SPUR II.

Palabras clave:
Reanimación cardiopulmonar
Fracción inspirada de oxígeno
Resucitador
Abstract

According to the ERC and the AHA guidelines, FiO2 should be titrated to achieve an O2Sat94%. The aim of this study was to determine the minimum oxygen flow and time needed to reach an FiO2 of 0.32 and 0.80 during post-cardiac arrest care. An experimental analysis was performed that consisted of a simulated post-cardiac arrest situation. Different resuscitators were tested and connected to an artificial lung: Mark IV, SPUR II, Revivator Res-Q, O-TWO. The oxygen flow levels tested were 2, 5, 10 and 15lpm. Bonferroni and Mann-Whitney U tests were used. An FiO2 of 0.32 or more was obtained using any of the oxygen flow and resuscitators. Only the Mark IV achieved an FiO2 of 0.80 after a minimum of 75s ventilating with 2 or 5lpm. Clinical and statistical differences (P<.05) were found: at 15lpm it took 35s to reach an FiO2 of 0.80 or more for Mark IV (85.6 [0.3]) and Revivator (84.3 [1.5]) compared to 50s for SPUR II (87.1 [6.4]); at 2lpm, all of the devices reached an FiO2 of0.32 at 30s(Mark IV (34.8 [1.3]), Revivator (35.7 [1.5]) and SPUR II (34.4 [2.1]), except for O-TWO, which took 35s (36.3 [4.3]). Patients could be ventilated with any of the resuscitators using 2lpm to obtain an FiO2 of 0.32, although possibly O-TWO would be the last option during the first 60s. In order to reach an FiO2 of 0.80, ventilating with 10lpm should be sufficient, and preferably using Mark IV or Revivator Res-Q. In conclusion, on observing the results of our study, in any possible scenario, it would be advisable to use Revivator Res-Q or Mark IV rather than O-TWO or SPUR II.

Keywords:
Cardiopulmonary resuscitation
Fraction of inspired oxygen
Bag valve mask device

Artículo

Opciones para acceder a los textos completos de la publicación Revista Española de Anestesiología y Reanimación
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Revista Española de Anestesiología y Reanimación

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos

Quizás le interese:
10.1016/j.redar.2022.06.002
No mostrar más