metricas
covid
Buscar en
Revista Española de Anestesiología y Reanimación
Toda la web
Inicio Revista Española de Anestesiología y Reanimación Derrame pleural unilateral tras perforación vascular por catéter venoso centra...
Información de la revista
Vol. 63. Núm. 1.
Páginas 54-57 (enero 2015)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Visitas
1327
Vol. 63. Núm. 1.
Páginas 54-57 (enero 2015)
CASO CLÍNICO
Derrame pleural unilateral tras perforación vascular por catéter venoso central de inserción periférica: utilidad del verde de indocianina en el diagnóstico
Unilateral pleural effusion caused by vessel perforation due to peripherally inserted central catheter: Indocyanine green as a diagnostic tool
Visitas
1327
L. Álvarez-Baenaa,
Autor para correspondencia
lucia.alvarezbaena@gmail.com

Autor para correspondencia.
, P. Duquea, R. Ramosa, L. Zarain Obradorb, L. Fernández-Queroa
a Departamento de Anestesiología y Reanimación, Hospital General Universitario Gregorio Marañón, Madrid, España
b Departamento de Cirugía General y Aparato Digestivo II, Hospital General Universitario Gregorio Marañón, Madrid, España
Este artículo ha recibido
Información del artículo
Resumen
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Figuras (3)
Mostrar másMostrar menos
Resumen

Varón de 44 años con desnutrición calórico-proteica grave en el contexto de una estenosis pilórica benigna, a quien se decidió colocar un catéter central de inserción periférica (CCIP) para tratamiento con nutrición parenteral. Al quinto día de la inserción del catéter, presentó un derrame pleural derecho masivo de color blanco e insuficiencia respiratoria tras la realización de una endoscopia digestiva alta para el tratamiento de la estenosis pilórica. Ante la sospecha inicial de quilotórax el paciente ingresó en la Unidad de Reanimación. Se administró verde de indocianina a través del CCIP, obteniendo a los 30min una coloración verdosa del contenido del derrame pleural; este resultado nos hizo sospechar que el derrame pleural era secundario a una perforación vascular por el CCIP con extravasación de la nutrición parenteral al espacio pleural. Se realizó una tomografía computarizada toracoabdominal, que confirmó la existencia de una perforación a nivel de la vena innominada.

La colocación de un CCIP puede asociarse a complicaciones graves, como la perforación de una vena central, por tanto, la correcta posición de un catéter central debe ser siempre comprobada. La prueba diagnóstica de elección de perforación vascular a nivel central es la tomografía computarizada con contraste; sin embargo, ante la existencia de derrame pleural en este contexto, es posible emplear un colorante que, administrado de forma intravenosa, oriente su diagnóstico in situ. En este caso se empleó el verde de indocianina con este objetivo.

Palabras clave:
Verde de indocianina
Perforación vascular
Catéter venoso central
Nutrición parenteral
Abstract

A peripherally inserted central catheter (PICC) was inserted into a 44-year-old man to provide parenteral nutrition in a protein-calorie malnutrition secondary to a benign pyloric stenosis. On the fifth day while monitoring the catheter, the patient presented with a massive whitish pleural effusion after undergoing gastric endoscopy in order to treat pyloric stenosis. Chylothorax was initially suspected, and the patient was admitted to a recovery unit. Indocyanine green was administered through the PICC, obtaining a greenish discoloration in the pleural effusion 30min later. This led to the diagnosis of a pleural effusion caused by a vessel perforation due to the PICC, leading to parenteral nutrition extravasation. Thoraco-abdominal computed tomography was performed, which confirmed an innominate vein perforation due to the PICC.

PICC insertion may be associated with severe complications, such as central vessel perforation, and therefore the correct position of a central catheter should be always checked. Intravenous computed tomography contrast is the gold standard for central vascular perforation diagnosis. However if a pleural effusion occurs in this context, it is possible to use a dye, which administered intravenously can lead us to the correct diagnosis in situ. Indocyanine green was used for this purpose in this case.

Keywords:
Indocyanine green
Vessel perforation
Central venous catheter
Parenteral nutrition

Artículo

Opciones para acceder a los textos completos de la publicación Revista Española de Anestesiología y Reanimación
Suscriptor
Suscriptor de la revista

Si ya tiene sus datos de acceso, clique aquí.

Si olvidó su clave de acceso puede recuperarla clicando aquí y seleccionando la opción "He olvidado mi contraseña".
Suscribirse
Suscribirse a:

Revista Española de Anestesiología y Reanimación

Comprar
Comprar acceso al artículo

Comprando el artículo el PDF del mismo podrá ser descargado

Precio 19,34 €

Comprar ahora
Contactar
Teléfono para suscripciones e incidencias
De lunes a viernes de 9h a 18h (GMT+1) excepto los meses de julio y agosto que será de 9 a 15h
Llamadas desde España
932 415 960
Llamadas desde fuera de España
+34 932 415 960
E-mail
Opciones de artículo
es en pt

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?

Você é um profissional de saúde habilitado a prescrever ou dispensar medicamentos

Quizás le interese:
10.1016/j.redar.2020.10.016
No mostrar más